Alar Just

Prof. Alar Just

Professor, Department of Civil Engineering and Architecture, Tallinn University of Technology
+1

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
PAPercy Festus Alao
Percy Festus Alao
Laetitia MarrotLaetitia Marrot
Laetitia Marrot
Heikko KallakasHeikko Kallakas
Heikko Kallakas
AJAlar Just
Alar Just
TPTriinu Poltimäe
Triinu Poltimäe
JKJaan Kers
Jaan Kers
The effects of surface pretreatment (water and alkali) and modification with silane on moisture sorption, water resistance, and reaction to fire of hemp fiber reinforced polylactic acid (PLA) composites at two fiber loading contents (30 and 50 wt.%) are investigated in this work. Moisture adsorption was evaluated at 30, 50, 75 and 95% relative humidity, and water resistance was determined after a 28-day immersion period. The cone calorimetry technique was used to investigate response to fire. The fiber surface treatment resulted in the removal of cell wall components, which increased fiber individualization and homogeneity as shown in scanning microscopic pictures of the composite cross-section. Although the improved fiber/matrix bonding increased the composite’s water resistance, the different fiber treatments generated equal moisture adsorption results for the 30 wt.% reinforced composites. Overall, increasing the fiber amount from 30 to 50 wt.% increased the composite sensitivity to moisture/water, mainly due to the availability of more hydroxyl groups and to the development of a higher pore volume, but fire protection improved due to a reduction in the rate of thermal degradation induced by the reduced PLA content. The new Oswin’s model predicted the composite adsorption isotherm well. The 30 wt.% alkali and silane treated hemp fiber composite had the lowest overall adsorption (9%) while the 50 wt.% variant produced the highest ignition temperature (181 ± 18 °C).

31 May 2018 in Fire Technology
Verified
Journal Article
Closed access
PDF file
JSJoachim Schmid
Joachim Schmid
MKMichael Klippel
Michael Klippel
AJAlar Just
Alar Just
AFAndrea Frangi
Andrea Frangi
MTMattia Tiso
Mattia Tiso

1 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
KSKristjan Saal
Kristjan Saal
Heikko KallakasHeikko Kallakas
Heikko Kallakas
Eero TuhkanenEero Tuhkanen
Eero Tuhkanen
AJAlar Just
Alar Just
ARAnti Rohumaa
Anti Rohumaa
Rynno LohmusRynno Lohmus
Rynno Lohmus
Fiber-reinforced plywood is a composite material that combines the natural strength and rigidity of plywood with the added durability and resilience provided by reinforcing fibers. This type of plywood is designed to offer improved characteristics over standard plywood, including enhanced strength, stiffness, resistance to impact and moisture, and environmental degradation. By integrating reinforcing fibers, such as glass, carbon, or natural fibers (like flax, bamboo, or hemp) into or onto plywood, manufacturers can create a material that is better suited for applications where traditional plywood might fall short or when a decrease in product weight or savings in wood raw material are necessary. This report reviews the current progress in fiber-reinforced plywood in the context of plywood as a construction material to better understand the potential gains in plywood applications, mechanical parameters, and material savings. It is found that a simple and cost-effective procedure of fiber reinforcement allows for substantial improvements in plywood’s mechanical properties, typically to the extent of 10–40%. It is suggested that the wider adoption of fiber-reinforced plywood, especially in load- and impact-bearing applications, would greatly contribute to enhanced durability and longevity of the material while also allowing for more sustainable use of raw wood material.

1 May 2017 in Structural Engineering International
Verified
Journal Article
Closed access
MTMattia Tiso
Mattia Tiso
AJAlar Just
Alar Just
Insulation materials have the potential to alter the fire resistance of timber frame assemblies. At present, Eurocode 5 Part 1-2 provides a model for the fire design of the load-bearing function of timber frame assemblies with cavities that are completely filled with stone wool. An extension of this model for glass wool in a post-protection phase has been published in the European Technical Guideline for Fire Safety in Timber Buildings. However, very little is known about the protection afforded by other insulation materials. This paper provides an overview of a study whereby model scale tests were performed with nine different insulation materials. The results of model scale furnace tests showed that the development of a 300°C isotherm on wood–insulation interfaces could be an indicator of the fire protection given by these insulations. Based on these findings, three different levels of fire protection with batt-type insulation materials are proposed. In this paper the most sensitive parameters that describe the protection against charring given by different insulations are analysed. The study offers some important insights into the concept of a new design model for the fire resistance of timber frame assemblies

19 February 2024 in Journal of Sustainable Architecture and Civil Engineering
Verified
Journal Article
Open access
PDF file
MKMaarja Kauniste
Maarja Kauniste
AJAlar Just
Alar Just
ETEero Tuhkanen
Eero Tuhkanen
TKTargo Kalamees
Targo Kalamees
Despite the growing popularity of wood and wood-based products in the construction industry, there has been insufficient focus on assessing the condition, preservation, and potential reuse of existing timber. While numerous standards evaluate the quality of freshly sawn timber, there is currently no standardized system for assessing the strength properties of aged and reused timber. The lack of these guidelines is also one of the reasons the results obtained in numerous research are often fluctuating, and we cannot draw clear conclusions. The matter is further complicated by the lack of data on old in-situ wood and its exploitation, which would help to evaluate its condition. Consequently, there is a real practical need to assess the condition of old timber to avoid unnecessary demolition and the loss of valuable and structurally sound building material. What sets this study apart from others is that, in addition to destructive testing, the 4-point non-destructive (ND) bending tests were conducted on all four faces of test specimens. This provided an opportunity to assess the wood visually and then find connections to associate external characteristics with real properties. This methodology aimed to determine whether it is feasible to visually assess the most practical way to use wooden elements in construction. If this question arises, which face of the beam would be better suited for the tension side and which for the compression side? The old timber used in testing originated from an old library building located on Vaksali Street, Tartu, Estonia and is estimated to be about 120 years old. This paper investigates and compares the collected data with a Nordic standard for grading fresh-sawn timber and two established Italian standards for visually assessing aged timber. This comparison contributes to developing a standardized framework for future visual assessments. ND and destructive four-point bending tests were performed to validate and find appropriate visual characteristics to determine the strength and stiffness of the timber elements. The primary goals of this study were first to compare the results obtained from existing ND methods with actual results and secondly to provide guidelines for better visual grading of wood in the future, based on Nordic Standard INSTA 142 (2010) and Italian standards UNI 11119 (2004) and UNI 11035 (2010) Contrary to previous research conclusions, the visual assessment results yielded unexpected outcomes. The results show that the grading standards significantly underestimated the real strength of the wood, and even more, none of the visual assessments overestimated the real strength of the specimens. Therefore, based on prior research and the findings derived from this study, there is evident a substantial potential for extensive development and optimization within this field.

24 March 2024 in Fire Technology
Verified
Journal Article
Closed access
PDF file
MKMiriam Kleinhenz
Miriam Kleinhenz
AJAlar Just
Alar Just
AFAndrea Frangi
Andrea Frangi