The purpose of this study was to verify the heart rate variability (HRV) and heart rate (HR) kinetics during the fundamental phase in different intensity domains of cycling exercise. Fourteen males performed five exercise sessions: (1) maximal incremental cycling test; (2) two rest‐to‐exercise transitions for each intensity domain, that is, heavy (Δ30) and severe (Δ60) domains. HRV markers (SD1 and SD2) and HR kinetics in the fundamental phase were analyzed by first‐order exponential fitting. There were no significant differences in amplitude values between SD1Δ30 (8.98 ± 3.52 ms) and SD1Δ60 (9.44 ± 3.24 ms) and SD2Δ30 (24.93 ± 9.16 ms) and SD2Δ60 (25.98 ± 7.29 ms). Significant difference was observed between HRΔ30 (52 ± 7 bpm) and HRΔ60 (63 ± 8 bpm). The time constant (τ) values were significantly different between SD1Δ30 (17.61 ± 6.26 s) and SD1Δ60 (13.86 ± 5.90 s), but not between SD2Δ30 (20.06 ± 3.73 s) and SD2Δ60 (19.47 ± 6.03 s) or HRΔ30 (56.75 ± 18.22 s) and HRΔ60 (58.49 ± 15.61 s). However, the τ values for HRΔ30 were higher and significantly different in relation to SD1Δ30 and SD2Δ30, as well as for HRΔ60 in relation to SD1Δ60 and SD2Δ60. The kinetics of the autonomic variable (SD1 marker) was accelerated by the increased intensity. Moreover, significant differences were found for the τ values, with faster HRV markers than HR, in both intensities of Δ30 and Δ60, which suggests that these variables indicate distinct and specific cardiac autonomic response times during different intensity domains in cycling.HIGHLIGHTS The application of HRV to optimize exercise prescription at different effort intensities is extremely important to obtain assertive and effective results. Analysis of the kinetic responses of HRV is a useful tool for the evaluation of exercise performance and health status. A faster kinetics was found for HRV markers in comparison to HR, for both intensities analysed, which suggests that these variables indicate distinct and specific cardiac autonomic response times during different intensity domains in cycling.
1 January 2024 in Revista Brasileira de Cineantropometria & Desempenho Humano
The worldwide prevalence of hypertension is 34%1 1 WHO: World Health Organization [Internet]. Global report on hypertension: the race against a silent killer. Switzerland: WHO; 2014 [cited 2024 Jan 19]. Available from: https://www.who.int/publications/i/item/9789240081062 https://www.who.int/publications/i/item/... . In Brazil, it affects about 32.5% of adults and more than 60% of the elderly2 2 Barroso WKS, Rodrigues CIS, Bortolotto LA, Mota-Gomes MA, Brandão AA, Feitosa A, et al. Diretrizes brasileiras de hipertensão arterial - 2020. Arq Bras Cardiol. 2020;116(3):516-658. http://dx.doi.org/10.36660/abc.20201238. PMid:33909761. http://dx.doi.org/10.36660/abc.20201238... . Hypertension is a multifactorial condition associated with metabolic disorders and changes in functionality and/or structure of target organs, being one of the main risk factors for global mortality and responsible for about 50% of deaths related to cardiovascular diseases (CVD)1 1 WHO: World Health Organization [Internet]. Global report on hypertension: the race against a silent killer. Switzerland: WHO; 2014 [cited 2024 Jan 19]. Available from: https://www.who.int/publications/i/item/9789240081062 https://www.who.int/publications/i/item/... ,2 2 Barroso WKS, Rodrigues CIS, Bortolotto LA, Mota-Gomes MA, Brandão AA, Feitosa A, et al. Diretrizes brasileiras de hipertensão arterial - 2020. Arq Bras Cardiol. 2020;116(3):516-658. http://dx.doi.org/10.36660/abc.20201238. PMid:33909761. http://dx.doi.org/10.36660/abc.20201238... .
6 February 2024 in Research Quarterly for Exercise and Sport
Purpose: This study aimed to compare the performance-derived parameters utilizing isolinear (ISOLIN) and isovelocity (ISOVEL) sprint cycling modes. Method: For that, 20 male trained cyclists performed 2 sprints of 7 s on an electromagnetically braked cycle ergometer in ISOLIN and six sprints in ISOVEL mode with cadences between 90 and 180 rpm, each separated by 3-min. A linear function modeled the sprints within each mode to extrapolate maximal cadence (CMAX) and torque (TMAX), and a quadratic function was used to extrapolate the apex defined as optimal cadence power (OPTCAD) and peak power output (PMAX). Fifteen subjects performed another 4 sprints at ISOLIN mode on different days to verify the reliability. Results: The measures from the power-cadence relationship were not different between the ISOLIN and ISOVEL modes. Although significant differences were detected in the T-C relationship, TMAX was greater at ISOLIN than ISOVEL (p = .006). On the other hand, CMAX was higher at ISOVEL than ISOLIN (p < .001). The correlation between parameters was large to very large (r = 0.51 to 0.89). However, high limits of agreement were verified. The ISOLIN presented consistency during the trials, and the random errors were acceptable (CV = 5.3% to 11.5%). Conclusion: Using the power-cadence relationship, PMAX and OPTCAD could be detected similarly between the two sprint modes (ISOLIN and ISOVEL). Thus, the findings demonstrated that a single ISOLIN sprint test could be a suitable tool for quantifying the time course of muscle fatigue during and after cycling exercises in well-trained male cyclists.
1 January 2026 in Applied Physiology, Nutrition, and Metabolism
Although physiological responses to flat versus incline running have been previously studied, the influence of slope on muscle deoxygenation and its relationship with physiological thresholds remains unclear. This study aimed to: (I) compare the deoxyhemoglobin breaking point (HHb-BP) between a slope-based and speed-based incremental running test, and (II) examine the agreement between HHb-BP and the second lactate threshold (LT 2 ) in both tests. Fifteen recreational trail runners completed two incremental running tests: (I) a speed-based test with a fixed 1% gradient and 1 km h −1 increments every 3 min, and (II) a slope-based test at a fixed speed (50% of peak speed from the speed-based test) with 2% gradient increase every 3 min. Cardiorespiratory variables, blood lactate concentration, and gastrocnemius muscle oxygenation were assessed. The %V̇O 2 max at HHb-BP, first lactate threshold (LT 1 ), and LT 2 was higher in the slope-based test, along with absolute V̇O 2 values at LT 1 and LT 2 . In the speed-based test, HHb-BP occurred at a lower intensity than LT 2 , with poor agreement between them, whereas no significant differences were found in the slope-based test. In conclusion, HHb-BP occurred at a higher %V̇O 2 max in the slope-based test. In the speed-based test, HHb-BP was observed at a lower intensity than LT 2 , with weak agreement between them. However, the differences in LT 1 and LT 2 between tests were dependent on the method used to determine them. These findings highlight the importance of the method applied to determine lactate thresholds and the influence of the slope in peripheral physiological threshold. ReBEC trial registration: ensaiosclinicos.gov.br/(RBR-4hx89v9).
This study aimed to assess the predictive capability of different critical power (CP) models on cycling exercise tolerance in the severe- and extreme-intensity domains. Nineteen cyclists (age: 23.0 ± 2.7 y) performed several time-to-exhaustion tests (Tlim) to determine CP, finite work above CP (W'), and the highest constant work rate at which maximal oxygen consumption was attained (IHIGH). Hyperbolic power-time, linear power-inverse of time, and work-time models with three predictive trials were used to determine CP and W'. Modeling with two predictive trials of the CP work-time model was also used to determine CP and W'. Actual exercise tolerance of IHIGH and intensity 5% above IHIGH (IHIGH+5%) were compared to those predicted by all CP models. Actual IHIGH (155 ± 30 s) and IHIGH+5% (120 ± 26 s) performances were not different from those predicted by all models with three predictive trials. Modeling with two predictive trials overestimated Tlim at IHIGH+5% (129 ± 33 s; p = 0.04). Bland-Altman plots of IHIGH+5% presented significant heteroscedasticity by all CP predictions, but not for IHIGH. Exercise tolerance in the severe and extreme domains can be predicted by CP derived from three predictive trials. However, this ability is impaired within the extreme domain.
1 November 2024 in International Journal of Sport Nutrition and Exercise Metabolism
This study aimed to investigate the effects of caffeine ingestion by chewing gum (GUMCAF) combined with priming exercise on pulmonary oxygen uptake () and near-infrared spectroscopy-derived muscle oxygen extraction (HHb + Mb) kinetics during cycling performed in a severe-intensity domain. Fifteen trained cyclists completed four visits: two under a placebo gum (GUMPLA) and two under GUMCAF ingestion. Each visit consisted of two square-wave cycling bouts at Δ70 intensity (70% of difference between the at first ventilatory threshold and ) with duration of 6 min each and 5 min of passive rest between the bouts. The GUMPLA or GUMCAF (400 mg) was chewed for 5 min, 12 min before the first Δ70 bout in a randomized double-blind procedure. The fundamental phase and slow component of HHb + Mb and kinetics were evaluated. For HHb + Mb kinetics, regardless of ingested gum, priming exercise effects occurred on the time constant (GUMCAF 16.0 ± 4.0 vs. 13.9 ± 2.9 s; GUMPLA 15.7 ± 6.1 vs. 13.2 ± 2.5 s), amplitude, slow component, time delay, and mean response time parameters (p ≤ .032). For kinetics, there were significant effects of bouts on the amplitude, slow component, end , and the gain kinetics parameters (p < .017). Baseline was higher during GUMCAF than GUMPLA (p = .020). No significant effects occurred for the interaction between gum and bout in any parameter of or HHb + Mb kinetics. Therefore, unlike the priming exercise in severe-intensity exercise, GUMCAF is not an effective strategy for improving or HHb + Mb kinetics acceleration.