1 February 2014 in European Journal of Radiology
1 July 2021 in European Journal of Radiology
9 April 2016 in Journal of Cardiothoracic Surgery
All studies involving use of ionizing radiation should be performed in accordance with the ALARA (As Low As Reasonably Achievable) principle, especially in children. In this study, the prospective ECG triggering technique with low voltage was used in dual-source computed tomography (DSCT) angiography to investigate if image quality with low radiation dose could be satisfactory in pediatric patients with congenital heart disease. Sixty pediatric patients with suspected congenital cardiovascular anomalies were enrolled prospectively in the study. They were randomly assigned to two groups for DSCT angiography. Group A were scanned by prospective ECG-triggering computed tomography angiography (CTA) with 80 kV tube voltage, while group B by used non-ECG-gated CTA with the same tube voltage. The anomaly accuracy was evaluated based on the surgical and/or conventional cardiac angiography findings. The overall image quality was assessed on a five-point scale. And the diagnostic accuracy and radiation dose was evaluated in both groups. There were 127 cardiovascular anomalies in Group A and 108 in Group B. The mean subjective image quality and diagnostic accuracy between these two groups were significantly different (P = 0.007 and 0.011, respectively). The mean effective dose in Group A and Group B was 0.38 ± 0.13 mSv and 0.35 ± 0.17 mSv, respectively. But there was no significant difference between two groups (P = 0.197). The prospective ECG triggering technique in DSCT scan can offer better image quality and diagnostic accuracy with low radiation exposure in pediatric patients with congenital heart diseases. This technique has potential to become a new clinical routine in pediatric cardiac computed tomography (CT) imaging.
2 March 2021 in Journal of Interventional Cardiology
Objectives. The purpose of this study was to review the experiences with transcatheter closure of mitral PVL after surgical valve replacement. Background. Transcatheter closure of paravalvular leak (PVL) is an intricate alternative to surgical closure. But it represents one of the most intricate procedures in the field of structural heart interventions, especially for patients with mitral PVL. Methods. From January 2015 through January 2019, 35 patients with mitral PVL after valve replacement underwent transcatheter closure. We reviewed the catheter techniques, perioperative characteristics, and prognosis. The median follow-up was 26 (348) months. Results. Acute procedural success was achieved in 33/35 (94.3) patients. Twenty-five patients had single mitral prosthetic valve replacements; 10 had combined aortic and mitral prosthetic valve replacements previously; 28 had mechanical valves; and 7 had bioprosthetic valves. All percutaneous procedures were performed with local anesthesia except for seven transapical cases with general anesthesia. Multiple approaches were used: transfemoral, transapical, and transseptal via an arteriovenous loop. Multiple devices were deployed. There were no hospital deaths. The procedural time was 67300 (124±62) minutes. Fluoroscopic time was 1750 (23.6±12.1) minutes. The hospital stay was 517 (8.3±3.2) days. Complications included recurrent hemolysis, residual regurgitation, acute renal insufficiency, and anemia. Twenty-seven (77.1) patients improved by 1 New York Heart Association functional class at the 1-year follow-up. Conclusions. Transcatheter mitral PVL closure requires complex catheter techniques. However, this minimally invasive treatment could provide reliable outcomes and shorter hospital stays in selected patients. This trial is registered with NCT02917980.
28 August 2023 in European Journal of Radiology
13 May 2023 in European Radiology