Diagnostic reference levels (DRLs) for positron emission tomography (PET/CT) examinations have not previously been established in Costa Rica, and data from Central America remain limited due to the restricted availability of PET/CT systems in the region. This study established local DRLs for administered 18F-FDG activity and CT dose metrics in 393 adult lymphoma patients undergoing PET/CT at the Cyclotron–PET/CT Laboratory (Centro de Investigación en Ciencias Atómicas, Nucleares y Moleculares), University of Costa Rica. DRLs were defined as the 75th percentile (P75), and the influence of patient body mass was assessed. The DRL for administered activity was 388.5 MBq (4.8 MBq kg−1). Whole-body CT DRLs were 12.1 mGy for Volume Computed Tomography Dose Index and 1250.2 mGy cm for dose-length product, while thorax CT DRLs were 8.5 mGy and 325.6 mGy cm, respectively. Dose metrics increased with patient body mass, whereas normalized activity values remained consistent with international practice. These findings provide the first PET/CT-specific DRLs for Costa Rica and support future national dose optimization and monitoring efforts.
Interventional cardiology procedures, particularly coronary angiography (CA) and percutaneous coronary intervention (PCI), are among the most radiation-intensive medical imaging techniques. Accurate estimation of patient radiation dose is essential for risk assessment, dose optimization, and the development of diagnostic reference levels. This scoping review critically analyzes the current literature on dose conversion factors based on kerma-area product (KAP) for estimating effective (E) and organ-specific (HT) doses in adult patients undergoing CA and PCI. A total of 14 studies meeting defined eligibility criteria were included, encompassing methodologies such as Monte Carlo simulations (e.g., PCXMC, Geant4), physical phantoms, and clinical measurements. Reported E/KAP factors varied from 0.14 to 0.33 mSv/Gy·cm², with PCI generally yielding higher values. HT/KAP values were notably highest for lungs and varied based on sex, anatomy, and procedural parameters. Technical factors such as X-ray filtration also significantly influenced dose estimation. The findings highlight substantial methodological heterogeneity and emphasize the need to standardize conversion factor recommendations across settings. Future efforts should focus on integrating personalized dosimetry, artificial intelligence tools, and real-time dose monitoring to enhance radiological safety and ensure consistent practice in interventional cardiology.
Dado el uso incrementado de la tomografía computarizada en la Caja Costarricense del Seguro Social durante los últimos 10 años, se ha vuelto cada vez más importante obtener imágenes de la calidad diagnóstica requerida con la mínima dosis de radiación posible al paciente. Para lograr esto, en los sistemas de tomografía computarizada se utiliza, rutinariamente, el control automático de exposición, el cual modula la corriente del tubo según la atenuación del haz que produce el paciente y que se obtiene en el escanograma. Objetivo: Comprobar el funcionamiento del control automático de exposición de un tomógrafo Canon Aquilion ONE en la dosis suministrada al paciente y verificar la importancia de realizar un simple o doble escanograma para diferentes protocolos clínicos. Métodos: Se analizó el comportamiento de la dosis, el ruido y la intensidad de la corriente obtenida en un maniquí con diferentes secciones elípticas que varían sus dimensiones en los ejes X-Y. Se determinó el producto dosis longitud en diferentes protocolos clínicos con el control automático de exposición activado debido a un simple o doble escanograma. Resultados: Para intensidades de corrientes fijas, a medida que aumenta el tamaño de cada sección del maniquí, la dosis se reduce, aproximadamente hasta el 72% y, cuando disminuye el tamaño de cada sección, mejora hasta en un 21% la calidad de la imagen debido a la reducción del ruido. Conclusiones: Se pudo observar que, a pesar de que las dosis para localización son bajas, la utilización de un simple escanograma, en la mayoría de los protocolos, no solo permite reducir la dosis suministrada al paciente, sino también efectuar menor cantidad de disparos en el equipo e incrementar la vida útil del tubo de rayos X, pues el aporte de un segundo escanograma no representa un impacto significativo en la calidad de imagen.