The objective of this study was to characterise thermoluminescent (TLDs) and optically stimulated luminescent dosimeters (OSLDs) at low X-ray energies and estimate the eye lens (DL), thyroid (DT) and mean glandular (DG) doses received during Full-Field Digital Mammography (FFDM) and Digital Breast Tomosynthesis (DBT). The dosimeters were characterised in mammography energies. DL, DT and DG were estimated in FFDM and DBT mode taping dosimeters on the skin of the thyroid gland and on the left eye lens of an Alderson phantom. Dosimeters were also placed on the top of a NORMI PAS phantom simulating a compressed breast. The accuracy, precision and lower limit of detection (LLD) for TLDs and OSLDs were 5 and 8%, 6 and 3%, and 38 and 11 μSv, respectively. The linearity of the kerma response had an R2 > 0.99 and energy dependence was lower than 40%. DT ranged from 0.40 to 2.87 μGy for FFDM and 1.27 to 5.99 μGy for DBT. DG was between 0.50 and 1.27 mGy for FFDM and 1.07 and 1.60 mGy for DBT. DL was below the LLD. Dosimeters showed good performance. DG values were lower than those found in the literature, whereas DT value agreed with references. Differences between DG and DT determined with OSLDs and TLDs were lower than 10% and 200%.
This study aimed to design and characterize a compressible phantom that simulates adipose, glandular, and mixed breast tissues for mammography applications. Samples were prepared using paraffin gel wax, silicone oil, glass microspheres, and silicone. The linear attenuation coefficients and effective atomic numbers calculated at 15 keV were 0.986 cm−1 and 5.97 for adipose tissue, 1.381 cm−1 and 7.81 for glandular tissue, and 1.772 cm−1 and 6.91 for the mixed sample. Densities and Young’s modulus values obtained from computed tomography and compression tests were 0.89 g·cm−3 and 24.75 kPa for adipose, 0.98 g·cm−3 and 31.26 kPa for glandular, and 0.95 g·cm−3 and 26.27 kPa for the mixed composition. Mammographic images were satisfactory, and the calculated mean glandular dose values closely matched those extracted from Digital Imaging and Communications in Medicine (DICOM) headers, with mixed and glandular samples showing similar values to patient data. Slight deviations from previously published results suggest potential areas for further refinement of phantom properties.
The measurement of air kerma in air (Kair) to estimate average glandular dose (AGD) received during digital breast tomosynthesis (DBT) studies is sometimes a difficult task. In this work, a novel methodology was implemented to measure Kair and half-value layer while the X-ray tube is rotating. A low economic cost support (LCS) was built to place aluminium sheets and a calibrated dosemeter. Three Fujifilm Innovality equipment were used and two dosemeters calibrated on W–Al energies. Validation of the new methodology was made against standard scheme and it was applied to estimate AGD for 300 patients and 7 phantoms. Validation analysis was satisfactory. The difference in the AGD calculated with the LCS and DICOM Header was lower than ±10%. AGD values ranged from 0.77 to 2.11 mGy and 0.85 to 2.15 mGy for phantoms and patients, respectively. The novel methodology has a potential use for DBT equipment without stationary mode.