Jitendra Kumar

Jitendra Kumar

Auto-generated profile, based on publicly available information

Jitendra Kumar

Department of Biomedical Engineering, B V Raju Institute of Technology, Narsapur, Medak, Telangana, India

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2022 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
JKJitendra Kumar
Jitendra Kumar
RVRati Verma
Rati Verma
NSNitesh Kumar Singh
Nitesh Kumar Singh
NNNeelam Shobha Nirala
Neelam Shobha Nirala
SRSanjay Kumar Rai
Sanjay Kumar Rai

1 June 2025 in Physics of Fluids
Verified
Journal Article
Closed access
BBBratajit Basu
Bratajit Basu
DKDimpal Khambhati
Dimpal Khambhati
JKJitendra Kumar
Jitendra Kumar
NSNitesh Kumar Singh
Nitesh Kumar Singh
KDKhemraj Deshmukh
Khemraj Deshmukh
Cryptic pregnancy, characterized by the absence of typical gestational indicators, poses significant diagnostic challenges. Current diagnostic tests based on biochemical markers such as Human Chorionic Gonadotropin cannot detect such pregnancies because of hormonal dysregulation. The objective of the present study was to evaluate the variation in different rheological parameters—Pressure, Shear rate, Axial velocity—in the uterine arteries using the Computational Fluid Dynamics (CFD) using the COMSOL. The CFD analysis was performed on the total 24 geometries generated from the two structures: S1, before cryptic pregnancy and S2, after cryptic pregnancy. The CFD studies were performed in no slip condition of the wall and viscosity of flowing fluid (equivalent to blood), which were considered both Newtonian and non-Newtonian in the presence of sinusoidal and pulsatile flow. The different rheological parameters were observed on points P1–P5 at the T cycle. Result indicated that non-Newtonian flows exhibited dominant oscillatory patterns in shear rate, pressure, and axial velocity, especially at points like P2 and P4. Newtonian flows showed linear smooth trends, while non-Newtonian fluids showed complex rheological behavior, indicating their potential role in cryptic pregnancy detection. It had been observed that for the structures S124, S125, and S126, pressure value initially rises at point P1, which is further increased from P2 to P5 (2 × 106 Pa) within the time duration from T/3 to T/2 s. Newtonian models are useful for a simplified description, ignoring non-Newtonian effects that may result in incorrect predictions of flow behavior, which can undermine the efficiency and reliability of fluid transport processes in artificial circulation devices, microfluidic systems, and industrial processes. This research identifies the importance of rheological analysis in providing an alternative, noninvasive early detection test, which improves diagnostic accuracy and maternal health outcomes.

11 May 2026 in Physica Scripta
Verified
Journal Article
Closed access
KDKhemraj Deshmukh
Khemraj Deshmukh
ARAnuj Rohatgi
Anuj Rohatgi
JKJitendra Kumar
Jitendra Kumar
BBBratajit Basu
Bratajit Basu
SSSiddhita Saini
Siddhita Saini
NSNitesh Kumar Singh
Nitesh Kumar Singh
This study presents a computational rheology approach to assess the impact of scaffold shape and fluid dynamics on biofilm suppression. CFD simulations used COMSOL Multiphysics 5.6, which included laminar flow, solid mechanics, and FSI modules, and the studies were conducted on 12 scaffold architectures, comprising solid scaffolds (10% porosity) and TPMSbased IWP scaffolds (50% and 70% porosity). Six inlet velocity profiles sinusoidal and physiological were utilized to evaluate axial velocity, pressure, shear rate, stress, strain tensor, strain principal, deformation gradient and displacement gradient under slip wall boundary conditions for both Newtonian and non-Newtonian fluid types. Data from 12 observation stations for a duration of 1.0 second (step of 0.1 s) exhibited significant variations: non-Newtonian fluid type under physiological flow had shown more biofilm-antagonistic responses, where a peak wall pressure of the orders of 10 4 Pa with peak shear rate of the orders of 4000-5000 s -1 for core channel regions were observed with micro-scale deformations suggesting suitability of non-Newtonian fluid suitability under physiological flow for elimination of biofilm growth onto the scaffolds. The findings marked the important observation of fluid rheology associated with solids that might interplay in controlling and preventing the implant-associated infections in patients.