Khemraj Deshmukh

Mr. Khemraj Deshmukh

National Institute of Technology Raipur, Raipur, Chhattīsgarh, International
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
KDKhemraj Deshmukh
Khemraj Deshmukh
Saurabh GuptaSaurabh Gupta
Saurabh Gupta
KMKUNAL MITRA
KUNAL MITRA
ABArindam Bit
Arindam Bit
3D bioprinting has emerged as a tool for developing in vitro tissue models for studying disease progression and drug development. The objective of the current study was to evaluate the influence of flow driven shear stress on the viability of cultured cells inside the luminal wall of a serpentine network. Fluid–structure interaction was modeled using COMSOL Multiphysics for representing the elasticity of the serpentine wall. Experimental analysis of the serpentine model was performed on the basis of a desirable inlet flow boundary condition for which the most homogeneously distributed wall shear stress had been obtained from numerical study. A blend of Gelatin-methacryloyl (GelMA) and PEGDA200 PhotoInk was used as a bioink for printing the serpentine network, while facilitating cell growth within the pores of the gelatin substrate. Human umbilical vein endothelial cells were seeded into the channels of the network to simulate the blood vessels. A Live-Dead assay was performed over a period of 14 days to observe the cellular viability in the printed vascular channels. It was observed that cell viability increases when the seeded cells were exposed to the evenly distributed shear stresses at an input flow rate of 4.62 mm/min of the culture media, similar to that predicted in the numerical model with the same inlet boundary condition. It leads to recruitment of a large number of focal adhesion point nodes on cellular membrane, emphasizing the influence of such phenomena on promoting cellular morphologies.

25 August 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
KDKhemraj Deshmukh
Khemraj Deshmukh
KMKUNAL MITRA
KUNAL MITRA
ABArindam Bit
Arindam Bit
The viscosity of fluid plays a major role in the flow dynamics of microchannels. Viscous drag and shear forces are the primary tractions for microfluidic fluid flow. Capillary blood vessels with a few microns diameter are impacted by the rheology of blood flowing through their conduits. Hence, regenerated capillaries should be able to withstand such impacts. Consequently, there is a need to understand the flow physics of culture media through the lumen of the substrate as it is one of the vital promoting factors for vasculogenesis under optimal shear conditions at the endothelial lining of the regenerated vessel. Simultaneously, considering the diffusive role of capillaries for ion exchange with the surrounding tissue, capillaries have been found to reorient themselves in serpentine form for modulating the flow conditions while developing sustainable shear stress. In the current study, S-shaped (S1) and delta-shaped (S2) serpentine models of capillaries were considered to evaluate the shear stress distribution and the oscillatory shear index (OSI) and relative residual time (RRT) of the derivatives throughout the channel (due to the phenomena of near-wall stress fluctuation), along with the influence of culture media rheology on wall stress parameters. The non-Newtonian power-law formulation was implemented for defining rheological viscosity of the culture media. The flow actuation of the media was considered to be sinusoidal and physiological, realizing the pulsatile blood flow behavior in the circulatory network. A distinct difference in shear stress distributions was observed in both the serpentine models. The S1 model showed higher change in shear stress in comparison to the S2 model. Furthermore, the non-Newtonian viscosity formulation was found to produce more sustainable shear stress near the serpentine walls compared to the Newtonian formulation fluid, emphasizing the influence of rheology on stress generation. Further, cell viability improved in the bending regions of serpentine channels compared to the long run section of the same channel.

11 March 2026 in Journal of Medical Devices
Verified
Journal Article
Closed access
JKJitendra Kumar
Jitendra Kumar
NSNitesh Kumar Singh
Nitesh Kumar Singh
KKKumar Kandukuri
Kumar Kandukuri
MJMukul Jain
Mukul Jain
KDKhemraj Deshmukh
Khemraj Deshmukh
Bone implants have transformed the field of orthopedics by offering an effective approach to bone repair and replacement. In this review, recent development of designing and manufacturing technologies, materials, bone implant structural architectures, and drug delivery systems are addressed. Additive manufacturing, especially 3D printing, is essential for making customizable bone implants with intricate geometry. The success of a bone implant depends on the selection of appropriate materials. Because of the high resistance to corrosion, the properties of being nontoxic and highly lightweight yet highly strong, the titanium alloy (Ti6Al4V) is vastly used. In addition, the bio-active ceramics hydroxyapatite is commonly used due to the property of the ceramics to enhance the osteeconductivity of the implant. However, the implant in the form of a solid implant can cause a difference in mechanical properties, ensuing in stress shielding. The realization of the designs in the form of porous structures in bone implants is of major importance in vascularization and bone ingrowth. The key approach of the designs is the variability of the sizes and the patterns of the pores, which enhance bone ingrowth and implant function; the bone implants represent the progress in bone regeneration. In the aspect of the localized and continuous release of the therapeutic medications from bone implants, there is major innovation. The approach of the technologies, which involve polymer-drug encapsulation, and the drug reservoir within the implant, highlights the methodologies being pursued. The recent advances in the manufacture of bone implants have been fueled by the integration of state-of-the-art technologies, optimized porosity structures, and efficient drug delivery technologies that have uncovered a new innovative pathway.

1 June 2025 in Physics of Fluids
Verified
Journal Article
Closed access
BBBratajit Basu
Bratajit Basu
DKDimpal Khambhati
Dimpal Khambhati
JKJitendra Kumar
Jitendra Kumar
NSNitesh Kumar Singh
Nitesh Kumar Singh
KDKhemraj Deshmukh
Khemraj Deshmukh
Cryptic pregnancy, characterized by the absence of typical gestational indicators, poses significant diagnostic challenges. Current diagnostic tests based on biochemical markers such as Human Chorionic Gonadotropin cannot detect such pregnancies because of hormonal dysregulation. The objective of the present study was to evaluate the variation in different rheological parameters—Pressure, Shear rate, Axial velocity—in the uterine arteries using the Computational Fluid Dynamics (CFD) using the COMSOL. The CFD analysis was performed on the total 24 geometries generated from the two structures: S1, before cryptic pregnancy and S2, after cryptic pregnancy. The CFD studies were performed in no slip condition of the wall and viscosity of flowing fluid (equivalent to blood), which were considered both Newtonian and non-Newtonian in the presence of sinusoidal and pulsatile flow. The different rheological parameters were observed on points P1–P5 at the T cycle. Result indicated that non-Newtonian flows exhibited dominant oscillatory patterns in shear rate, pressure, and axial velocity, especially at points like P2 and P4. Newtonian flows showed linear smooth trends, while non-Newtonian fluids showed complex rheological behavior, indicating their potential role in cryptic pregnancy detection. It had been observed that for the structures S124, S125, and S126, pressure value initially rises at point P1, which is further increased from P2 to P5 (2 × 106 Pa) within the time duration from T/3 to T/2 s. Newtonian models are useful for a simplified description, ignoring non-Newtonian effects that may result in incorrect predictions of flow behavior, which can undermine the efficiency and reliability of fluid transport processes in artificial circulation devices, microfluidic systems, and industrial processes. This research identifies the importance of rheological analysis in providing an alternative, noninvasive early detection test, which improves diagnostic accuracy and maternal health outcomes.

28 March 2025 in Journal of Information Systems Engineering and Management
Verified
Journal Article
Open access
PDF file
MTMr.Bharat Tank
Mr.Bharat Tank
DPDr.Mitul Patel
Dr.Mitul Patel
KDKhemraj Deshmukh
Khemraj Deshmukh
The global coronavirus disease (COVID-19) pandemic has highlighted the urgent need for accessible, effective, and accurate diagnostic tools, especially in low- or no-service settings. Chest X-ray, a widely used diagnostic test, provides a rapid and non-invasive way to identify COVID-19 symptoms. Deploying deep learning models for COVID-19 detection on resource-constrained edge devices, such as the Raspberry Pi 4, requires a balance between model accuracy, inference speed, and hardware limitations. This study evaluates the performance of four deep learning models—ResNet18, ResNet50, DenseNet121, and SqueezeNet—based on key metrics such as inference time, memory usage, and model size after TensorFlow Lite conversion. Experimental results show that SqueezeNet offers the best trade-off, achieving the fastest inference time (10.76s per 100 images) and the lowest memory usage (2.8MB), making it the most suitable for real-time edge deployment. In contrast, ResNet50, despite its high accuracy, has the longest inference time (42.32s) and highest memory consumption (90MB), limiting its feasibility for Raspberry Pi-based applications. The findings highlight the importance of selecting lightweight architectures for efficient and scalable deep learning-based COVID-19 detection on edge devices. Detailed performance parameters including sensitivity, specificity, accuracy, reproducibility, and inference time were analysed to assess the suitability of each model for clinical trials. This study demonstrates the revolutionary potential of combining deep learning with portable devices to provide effective diagnostic tests for COVID-19 and similar respiratory diseases, address healthcare inequities, and facilitate timely interventions for epidemic control.

14 March 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
KDKhemraj Deshmukh
Khemraj Deshmukh
ABArindam Bit
Arindam Bit
The analysis of degradation in the presence of cell death and migration is a critical aspect of research in various biological fields, such as tissue engineering, regenerative medicine, and disease pathology. In present study, numerical study of degradation of scaffold were performed in present of cells, cell apoptosis and cell migration. A poly electrolyte complex (PEC) silk fibroin scaffold was used for degradation study. Degradation study in the presence of cells and migration were performed at fixed pH concentration 7.2. Similarly, degradation study of scaffold were performed at different pH cell apoptosis. A transient analysis of scaffold was evaluated in COMSOL 5.5 in presence of cryogenic temperature at different temperature gradient. The parameters; temperature, stress, strain tensor and deformation gradient associated with the degradation of polyelectrolyte complex scaffold were evaluated. Result shows that in both geometries minimum temperature had been achieved as 230.051 K at point P4 in series view and parallel view and at a point P3 for cell migration study for −5 k min−1 and −1 k min−1, respectively. The maximum stress had been generated for 5.57 × 107 N m−2 for the temperature gradient of −2 K min−1 at T cycle in the case of cell migration study. In contrast in series view the maximum stress 2.9 × 107 N m−2 were observed at P4 which was higher as compare to P3. Similarly, for a parallel view, maximum stress (3.93 × 107 N m−2) was obtained for point P3. It had been observed that the maximum strain tensor 5.21 × 10−3, 5.15 × 10−3 and 5.26 × 10−3 was generated in series view at 230 k on a point P3 for − 1, −2 and −5 K min−1, respectively. Similarly, the maximum strain tensor 8.16 × 10−3, 8.09 × 10−3 and 8.09 × 10−3 was generated in parallel view at 230 k on a point P3 for −1, −2 and −5 K min−1, respectively. In the presence of cells, at a point P4 for temperature gradient of −1 and −2 K min−1, it had been closed to the scaffold wall, which had a different temperature profile than the point P3 and scaffold comes to the contact with the cells. The analysis of PEC scaffold degradation in the presence of cells, including cell apoptosis and migration, offers significant insights into the relationship between scaffold properties, cell behaviour, and tissue regeneration.