David Peter Siddons

David Peter Siddons

Auto-generated profile, based on publicly available information

David Peter Siddons

National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2016 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
UBUlrike Boesenberg
Ulrike Boesenberg
CRChristopher G. Ryan
Christopher G. Ryan
RKRobin Kirkham
Robin Kirkham
DSD. Peter Siddons
D. Peter Siddons
MAMatthias Alfeld
Matthias Alfeld
GFGerald Falkenberg
Gerald Falkenberg

1 July 2000 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Closed access
PDF file
TBT. J. Boggon
T. J. Boggon
JHJohn Helliwell
John Helliwell
RJR. A. Judge
R. A. Judge
AOAndrzej Olczak
Andrzej Olczak
DSD. P. Siddons
D. P. Siddons
VSV. Stojanoff
V. Stojanoff

21 October 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSD. P. Siddons
D. P. Siddons
AKA. J. Kuczewski
A. J. Kuczewski
ARAbdul Rumaiz
Abdul Rumaiz
RTR. Tappero
R. Tappero
Mourad IdirMourad Idir
Mourad Idir
XYXin Yuan
Xin Yuan
The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 µm openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 µm-thick silicon nitride membrane. The gold is 25 µm thick, offering good contrast up to 20 keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.

10 February 2016 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ARAbdul Rumaiz
Abdul Rumaiz
DSD. Peter Siddons
D. Peter Siddons
GDGrzegorz Deptuch
Grzegorz Deptuch
PMPiotr Maj
Piotr Maj
AKAnthony J. Kuczewski
Anthony J. Kuczewski
MSMark Sutton
Mark Sutton
The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allowscontinuousacquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operatecontinuouslyin the microsecond time frame, while at the same time probing longer timescales.

28 June 2017 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Open access
GDGrzegorz W. Deptuch
Grzegorz W. Deptuch
FFFarah Fahim
Farah Fahim
PGPawel Grybos
Pawel Grybos
JHJim Hoff
Jim Hoff
SHScott Holm
Scott Holm
TZTom Zimmerman
Tom Zimmerman
An on-chip implementable algorithm for allocation of an X-ray photon imprint, called a hit, to a single pixel in the presence of charge sharing in a highly segmented pixel detector is described. Its proof-of-principle implementation is also given supported by the results of tests using a highly collimated X-ray photon beam from a synchrotron source. The algorithm handles asynchronous arrivals of X-ray photons. Activation of groups of pixels, comparisons of peak amplitudes of pulses within an active neighborhood and finally latching of the results of these comparisons constitute the three procedural steps of the algorithm. A grouping of pixels to one virtual pixel, that recovers composite signals and event driven strobes, to control comparisons of fractional signals between neighboring pixels are the actuators of the algorithm. The circuitry necessary to implement the algorithm requires an extensive inter-pixel connection grid of analog and digital signals, that are exchanged between pixels. A test-circuit implementation of the algorithm was achieved with a small array of 32 × 32 pixels and the device was exposed to an 8 keV highly collimated to a diameter of 3-μm X-ray beam. The results of these tests are given in this paper assessing physical implementation of the algorithm.

1 May 1998 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
DSD. P. Siddons
D. P. Siddons