Mourad Idir

Dr. Mourad Idir

Optical Metrology Group Leader, Energy Sciences Directorate/Photon Science Division, Brookhaven National Laboratory-NSLS II, Upton, NY 11973-5000, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
PSPeng Su
Peng Su
YWYuhao Wang
Yuhao Wang
JBJames H. Burge
James H. Burge
KKKonstantine Kaznatcheev
Konstantine Kaznatcheev
Mourad IdirMourad Idir
Mourad Idir
In a previous paper, the University of Arizona (UA) has developed a measurement technique called: Software Configurable Optical Test System (SCOTS) based on the principle of reflection deflectometry. In this paper, we present results of this very efficient optical metrology method applied to the metrology of X-ray mirrors. We used this technique to measure surface slope errors with precision and accuracy better than 100 nrad (rms) and ~200 nrad (rms), respectively, with a lateral resolution of few mm or less. We present results of the calibration of the metrology systems, discuss their accuracy and address the precision in measuring a spherical mirror.

25 February 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSDieter K. Schneider
Dieter K. Schneider
WSWuxian Shi
Wuxian Shi
BABabak Andi
Babak Andi
JJJean Jakoncic
Jean Jakoncic
YGYuan Gao
Yuan Gao
MFMartin Fuchs
Martin Fuchs
Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s−1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s−1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

30 January 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
Mourad IdirMourad Idir
Mourad Idir
KKKonstantine Kaznatcheev
Konstantine Kaznatcheev
GDGuillaume Dovillaire
Guillaume Dovillaire
JLJerome Legrand
Jerome Legrand
RRRakchanok Rungsawang
Rakchanok Rungsawang
We present a 2D Slope measuring System based on a Stitching Shack Hartmann Optical Head (SSH-OH) aiming to perform high accuracy optical metrology for X-ray mirrors. This system was developed to perform high-accuracy automated metrology for extremely high quality optical components needed for synchrotrons or Free Electrons Lasers (FEL), EUV lithography and x-ray astronomy with slope error accuracy better than 50 nrad rms.

21 October 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSDieter K. Schneider
Dieter K. Schneider
ASAlexei Soares
Alexei Soares
ELEdwin O. Lazo
Edwin O. Lazo
DKDale F. Kreitler
Dale F. Kreitler
KQKun Qian
Kun Qian
JJJean Jakoncic
Jean Jakoncic
The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 1012 photons s−1), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.

29 July 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ENEvgeny Nazaretski
Evgeny Nazaretski
DCD. S. Coburn
D. S. Coburn
WXWeihe Xu
Weihe Xu
JMJ. Ma
J. Ma
HXH. Xu
H. Xu
YCY. S. Chu
Y. S. Chu
The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

9 August 2016 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
LZLin Zhou
Lin Zhou
Lei HuangLei Huang
Lei Huang
BNBouet Nathalie
Bouet Nathalie
KKKonstantine Kaznatcheev
Konstantine Kaznatcheev
MVMatthew Vescovi
Matthew Vescovi
Mourad IdirMourad Idir
Mourad Idir