Bing Zhang

Bing Zhang

Auto-generated profile, based on publicly available information

Bing Zhang

RIOH High Science and Technology Group, Beijing 100088, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LPLu Peng
Lu Peng
GJGen-qiang Jing
Gen-qiang Jing
ZLZhu Luo
Zhu Luo
XYXin Yuan
Xin Yuan
YWYixu Wang
Yixu Wang
BZBing Zhang
Bing Zhang
Deformation is a ubiquitous phenomenon in nature. This process usually refers to the change in shape, size, and position of an object in the time and spatial domain under various loads. Under normal circumstances, during engineering construction, technicians are generally required to monitor the safe operation of structural facilities in the transportation field and the health of bridge, because monitoring in the engineering process plays an important role in construction safety. Considering the reliability risk of sensors after a long-time work period, such as signal drift, accurate measurement of strain gauges is inseparable from the value traceability system of high-precision strain gauges. In this study, two vibrating wire strain gauges with the same working principle were measured using the parallel method at similar positions. First, based on the principle of time series, the experiment used high-frequency dynamic acquisition to measure the thermometer strain of two vibrating wire strain gauges. Second, this experiment analyzed the correlation between strain and temperature measured separately. Under the condition of different prestress, this experiment studied the influencing relationship of temperature corresponding variable. In this experiment, the measurement repetitiveness was analyzed using the meteorology knowledge of single sensor data, focused on researching the influence of temperature and prestress effect on sensors by analyzing differences of their measurement results in a specified situation. Then, the reliability and stability of dynamic vibrating wire strain gauge were verified in the experiment. The final conclusion of the experiment is the actual engineering in the later stage. Onsite online meteorology in the application provides support.

10 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
XLXu Liu
Xu Liu
YJYuntong Jia
Yuntong Jia
LLLu Liu
Lu Liu
Jiacheng CaiJiacheng Cai
Jiacheng Cai
BZBing Zhang
Bing Zhang
GJGen-qiang Jing
Gen-qiang Jing
This paper mainly conducts research on the electrode distribution of the multi-electrode electromagnetic flow measurement system. Through simulation work, the weight function of the area to which the electrodes on the pipeline cross-section belong with respect to the potential difference is roughly obtained. Moreover, by comparing the simulation data with the actual experimental data, the correctness of the simulation work is verified. Tikhonov regularization is utilized to inversely solve the average velocity of the electrode area, and the TR-CNN algorithm is established to refine the velocity field of the pipeline cross-section in question. It mainly introduces the influence of different electrode placement methods on the potential difference. The results show that it has a relatively small impact on the velocity distribution of the fluid cross-section before flowing through the elbow, and the potential difference is highly sensitive to the velocity in the area where the magnetic induction coil and the electrodes are relatively close. The Pitot tube is used to conduct verification measurements on the fluid velocity field in the pipeline. The results indicate that as the measurement points are farther away from the elbow, the “skewing” phenomenon of the fluid flow velocity gradually weakens. In terms of prediction performance, the mean square error (MSE) of the cross-section error is approximately 0.015, and the mean absolute error (MAE) is about 0.095. These error indicators jointly demonstrate that the system has a relatively high measurement accuracy in practical applications.