Franco Molteni

Franco Molteni

Auto-generated profile, based on publicly available information

Franco Molteni

Villa Beretta Rehabilitation Center, Valduce Hospital, Lecco, Italy

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
SFSimona Ferrante
Simona Ferrante
EAEmilia Ambrosini
Emilia Ambrosini
MGMarta Gandolla
Marta Gandolla
CCClaudia Casellato
Claudia Casellato
Giancarlo FerrignoGiancarlo Ferrigno
Giancarlo Ferrigno
MUNDUS is an assistive framework for recovering direct interaction capability of severely motor impaired people based on arm reaching and hand functions. It aims at achieving personalization, modularity and maximization of the user’s direct involvement in assistive systems. To this, MUNDUS exploits any residual control of the end-user and can be adapted to the level of severity or to the progression of the disease allowing the user to voluntarily interact with the environment. MUNDUS target pathologies are high-level spinal cord injury (SCI) and neurodegenerative and genetic neuromuscular diseases, such as amyotrophic lateral sclerosis, Friedreich ataxia, and multiple sclerosis (MS). The system can be alternatively driven by residual voluntary muscular activation, head/eye motion, and brain signals. MUNDUS modularly combines an antigravity lightweight and non-cumbersome exoskeleton, closed-loop controlled Neuromuscular Electrical Stimulation for arm and hand motion, and potentially a motorized hand orthosis, for grasping interactive objects. The definition of the requirements and of the interaction tasks were designed by a focus group with experts and a questionnaire with 36 potential end-users. Five end-users (3 SCI and 2 MS) tested the system in the configuration suitable to their specific level of impairment. They performed two exemplary tasks: reaching different points in the working volume and drinking. Three experts evaluated over a 3-level score (from 0, unsuccessful, to 2, completely functional) the execution of each assisted sub-action. The functionality of all modules has been successfully demonstrated. User’s intention was detected with a 100% success. Averaging all subjects and tasks, the minimum evaluation score obtained was 1.13 ± 0.99 for the release of the handle during the drinking task, whilst all the other sub-actions achieved a mean value above 1.6. All users, but one, subjectively perceived the usefulness of the assistance and could easily control the system. Donning time ranged from 6 to 65 minutes, scaled on the configuration complexity. The MUNDUS platform provides functional assistance to daily life activities; the modules integration depends on the user’s need, the functionality of the system have been demonstrated for all the possible configurations, and preliminary assessment of usability and acceptance is promising.

1 May 2014 in NeuroImage
Verified
Journal Article
Open access
GMGandolla Marta
Gandolla Marta
SFSimona Ferrante
Simona Ferrante
FMFranco Molteni
Franco Molteni
EGEleonora Guanziroli
Eleonora Guanziroli
TFTiziano Frattini
Tiziano Frattini
NWNick S. Ward
Nick S. Ward
The standard account of motor control considers descending outputs from primary motor cortex (M1) as motor commands and efference copy. This account has been challenged recently by an alternative formulation in terms of active inference: M1 is considered as part of a sensorimotor hierarchy providing top–down proprioceptive predictions. The key difference between these accounts is that predictions are sensitive to the current proprioceptive context, whereas efference copy is not. Using functional electric stimulation to experimentally manipulate proprioception during voluntary movement in healthy human subjects, we assessed the evidence for context sensitive output from M1. Dynamic causal modeling of functional magnetic resonance imaging responses showed that FES altered proprioception increased the influence of M1 on primary somatosensory cortex (S1). These results disambiguate competing accounts of motor control, provide some insight into the synaptic mechanisms of sensory attenuation and may speak to potential mechanisms of action of FES in promoting motor learning in neurorehabilitation.

18 July 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MFMarcello Fusca
Marcello Fusca
FNFrancesco Negrini
Francesco Negrini
Paolo PeregoPaolo Perego
Paolo Perego
LMLuciana Magoni
Luciana Magoni
FMFranco Molteni
Franco Molteni
Giuseppe AndreoniGiuseppe Andreoni
Giuseppe Andreoni
Miniaturized wearable Inertial Measurement Units (IMU) offer new opportunities for the functional assessment of motor functions for medicine, sport, and ergonomics. Sparse reliability validation studies have been conducted without a common specific approach and protocol. A set of guidelines to design validation protocol for these systems is proposed hereafter. They are based on the comparison between video analysis and the gold standard optoelectronic motion capture system for Gait Analysis (GA). A setup of the protocol has been applied to a wearable device implementing an inertial measurement unit and a dedicated harmonic oscillator kinematic model of the center of mass. In total, 10 healthy volunteers took part in the study, and four trials of walking at a self-selected speed and step length have been simultaneously recorded by the two systems, analyzed, and compared blindly (40 datasets). The model detects the steps and the foot which supports body weight. The stride time and the cadence have a mean absolute percentage error of 5.7% and 4.9%, respectively. The mean absolute percentage error in the measurement of step’s length and step’s speed is 5.6% and 13.5%, respectively. Results confirm that the proposed methodology is complete and effective. It is demonstrated that the developed wearable system allows for a reliable assessment of human gait spatio-temporal parameters. Therefore, the goal of this paper is threefold. The first goal is to present and define structured Protocol Design Guidelines, where the related setup is implemented for the validation of wearable IMU systems particularly dedicated to GA and gait monitoring. The second goal is to apply these Protocol Design Guidelines to a case study in order to verify their feasibility, user-friendliness, and efficacy. The third goal is the validation of our biomechanical kinematic model with the gold standard reference.

1 January 2011 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
SFSimona Ferrante
Simona Ferrante
EAEmilia Ambrosini
Emilia Ambrosini
PRPaola Ravelli
Paola Ravelli
EGEleonora Guanziroli
Eleonora Guanziroli
FMFranco Molteni
Franco Molteni
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
The restoration of walking ability is the main goal of post-stroke lower limb rehabilitation and different studies suggest that pedaling may have a positive effect on locomotion. The aim of this study was to explore the feasibility of a biofeedback pedaling treatment and its effects on cycling and walking ability in chronic stroke patients. A case series study was designed and participants were recruited based on a gait pattern classification of a population of 153 chronic stroke patients.

14 January 2021 in Brain Sciences
Verified
Journal Article
Open access
PDF file
FMFranco Molteni
Franco Molteni
EGEleonora Guanziroli
Eleonora Guanziroli
Michela GoffredoMichela Goffredo
Michela Goffredo
Rocco Salvatore Salvatore CalabròRocco Salvatore Salvatore Calabrò
Rocco Salvatore Salvatore Calabrò
Sanaz PournajafSanaz Pournajaf
Sanaz Pournajaf
OGon behalf of Italian Eksogait Study Group
on behalf of Italian Eksogait Study Group
Background: Overground Robot-Assisted Gait Training (o-RAGT) provides intensive gait rehabilitation. This study investigated the efficacy of o-RAGT in subacute stroke subjects, compared to conventional gait training. Methods: A multicenter randomized controlled trial was conducted on 75 subacute stroke subjects (38 in the Experimental Group (EG) and 37 in the Control Group (CG)). Both groups received 15 sessions of gait training (5 sessions/week for 60 min) and daily conventional rehabilitation. The subjects were assessed at the beginning (T1) and end (T2) of the training period with the primary outcome of a 6 Minutes Walking Test (6MWT), the Modified Ashworth Scale of the Affected lower Limb (MAS-AL), the Motricity Index of the Affected lower Limb (MI-AL), the Trunk Control Test (TCT), Functional Ambulation Classification (FAC), a 10 Meters Walking Test (10MWT), the modified Barthel Index (mBI), and the Walking Handicap Scale (WHS). Results: The 6MWT increased in both groups, which was confirmed by both frequentist and Bayesian analyses. Similar outcomes were registered in the MI-AL, 10MWT, mBI, and MAS-AL. The FAC and WHS showed a significant number of subjects improving in functional and community ambulation in both groups at T2. Conclusions: The clinical effects of o-RAGT were similar to conventional gait training in subacute stroke subjects. The results obtained in this study are encouraging and suggest future clinical trials on the topic.

3 January 2023 in Brain Sciences
Verified
Journal Article
Open access
PDF file
ALAlberto Loro
Alberto Loro
MBMargherita Beatrice Borg
Margherita Beatrice Borg
MBMarco Battaglia
Marco Battaglia
AAAngelo Paolo Amico
Angelo Paolo Amico
RARoberto Antenucci
Roberto Antenucci
Alessio BaricichAlessio Baricich
Alessio Baricich
Background: Balance impairment is a common disability in post-stroke survivors, leading to reduced mobility and increased fall risk. Robotic gait training (RAGT) is largely used, along with traditional training. There is, however, no strong evidence about RAGT superiority, especially on balance. This study aims to determine RAGT efficacy on balance of post-stroke survivors. Methods: PubMed, Cochrane Library, and PeDRO databases were investigated. Randomized clinical trials evaluating RAGT efficacy on post-stroke survivor balance with Berg Balance Scale (BBS) or Timed Up and Go test (TUG) were searched. Meta-regression analyses were performed, considering weekly sessions, single-session duration, and robotic device used. Results: A total of 18 trials have been included. BBS pre-post treatment mean difference is higher in RAGT-treated patients, with a pMD of 2.17 (95% CI 0.79; 3.55). TUG pre-post mean difference is in favor of RAGT, but not statistically, with a pMD of −0.62 (95%CI − 3.66; 2.43). Meta-regression analyses showed no relevant association, except for TUG and treatment duration (β = −1.019, 95% CI − 1.827; −0.210, p-value = 0.0135). Conclusions: RAGT efficacy is equal to traditional therapy, while the combination of the two seems to lead to better outcomes than each individually performed. Robot-assisted balance training should be the focus of experimentation in the following years, given the great results in the first available trials. Given the massive heterogeneity of included patients, trials with more strict inclusion criteria (especially time from stroke) must be performed to finally define if and when RAGT is superior to traditional therapy.