Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ARA R
A R
APAlireza R. Panna
Alireza R. Panna
SPShamith U. Payagala
Shamith U. Payagala
MKMattias Kruskopf
Mattias Kruskopf
MKMarlin E. Kraft
Marlin E. Kraft
RERandolph E. Elmquist
Randolph E. Elmquist
We report the performance of a quantum Hall resistance standard based on epitaxial graphene maintained in a 5-T tabletop cryocooler system. This quantum resistance standard requires no liquid helium and can operate continuously, allowing year-round accessibility to quantized Hall resistance measurements. The ν = 2 plateau, with a value of R K /2, also seen as R H , is used to scale to 1 kQ using a binary cryogenic current comparator (BCCC) bridge and a direct current comparator (DCC) bridge. The uncertainties achieved with the BCCC are such as those obtained in the state-of-the-art measurements using GaAs-based devices. BCCC scaling methods can achieve large resistance ratios of 100 or more, and while room temperature DCC bridges have smaller ratios and lower current sensitivity, they can still provide alternate resistance scaling paths without the need for cryogens and superconducting electronics. Estimates of the relative uncertainties of the possible scaling methods are provided in this report, along with a discussion of the advantages of several scaling paths. The tabletop system limits are addressed as are potential solutions for using graphene standards at higher currents.

28 June 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DJDean G. Jarrett
Dean G. Jarrett
CYChing-Chen Yeh
Ching-Chen Yeh
SPShamith U. Payagala
Shamith U. Payagala
APAlireza R. Panna
Alireza R. Panna
YYYanfei Yang
Yanfei Yang
ARA R
A R
Advances in the development of graphene-based technology have enabled improvements in DC resistance metrology. Devices made from epitaxially grown graphene have replaced the GaAs-based counterparts, leading to an easier and more accessible realization of the ohm. By optimizing the scale of the growth, it has become possible to fabricate quantized Hall array resistance standards (QHARS) with nominal values between 1 kΩ and 1.29 MΩ. One of these QHARS device designs accommodates a value of about 1.01 MΩ, which made it an ideal candidate to pursue a proof-of-concept that graphene-based QHARS devices are suitable for forming wye-delta resistance networks. In this work, the 1.01 MΩ array output nearly 20.6 MΩ due to the wye-delta transformation, which itself is a special case of star-mesh transformations. These mathematical equivalence principles allow one to extend the QHR to the 100 MΩ and 10 GΩ resistance levels with fewer array elements than would be necessary for a single array with many more elements in series. The 1.01 MΩ device shows promise that the wye-delta transformation can shorten the calibration chain, and, more importantly, provide a chain with a more direct line to the quantum SI.

9 October 2023 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
DSD. S. Scaletta
D. S. Scaletta
SMSwapnil Milind Mhatre
Swapnil Milind Mhatre
NTN. T. M. Tran
N. T. M. Tran
CYC. H. Yang
C. H. Yang
HHH. M. Hill
H. M. Hill
ARA R
A R
A mathematical approach is adopted for optimizing the number of total device elements required for obtaining high effective quantized resistances in graphene-based quantum Hall array devices. This work explores an analytical extension to the use of star–mesh transformations such that fractal-like, or recursive, device designs can yield high enough resistances (like 1 EΩ, arguably the highest resistance with meaningful applicability) while still being feasible to build with modern fabrication techniques. Epitaxial graphene elements are tested, whose quantized Hall resistance at the ν=2 plateau (RH≈ 12 906.4 Ω) becomes the building block for larger effective, quantized resistances. It is demonstrated that, mathematically, one would not need more than 200 elements to achieve the highest pertinent resistances.

12 August 2025 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
LRLinsey K. Rodenbach
Linsey K. Rodenbach
JUJason M. Underwood
Jason M. Underwood
NTNgoc Thanh Mai Tran
Ngoc Thanh Mai Tran
APAlireza R. Panna
Alireza R. Panna
MAMolly P. Andersen
Molly P. Andersen
DGDavid Goldhaber-Gordon
David Goldhaber-Gordon

31 December 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
MFMona Feige
Mona Feige
SSStephan Schlamminger
Stephan Schlamminger
AKAndrew D. Koffman
Andrew D. Koffman
DJDean G. Jarrett
Dean G. Jarrett
SPShamith Payagala
Shamith Payagala
YWYicheng Wang
Yicheng Wang
We tested a digital impedance bridge in a hybrid structure for comparison of a capacitor with a resistor where the impedance ratio was measured in two separate parts. The modulus of the impedance ratio was matched arbitrarily close to the input-to-output ratio, in magnitude, of a two-stage inductive voltage divider by adjusting the operating frequency of the bridge; the residual deviation between the two together with the phase factor of the impedance ratio was measured using a custom detection system based on a four-channel 24-bit digitizer. The ratio of the inductive voltage divider was calibrated, in situ, using a conventional four-arm bridge with two known capacitors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the digitizer error. We have achieved an overall bridge resolution and stability of 0.02 μF/F in 2 hours for measuring a 100 pF capacitor relative to a 12906 Ω resistor at 1233 Hz. The relative combined standard uncertainty (k = 1) is 0.13 μF/F, dominated by the digitizer error.

28 October 2022 in Metrologia
Verified
Journal Article
Closed access
TOT Oe
T Oe
SPS Payagala
S Payagala
APA R Panna
A R Panna
STS Takada
S Takada
NKN-H Kaneko
N-H Kaneko
DJD G Jarrett
D G Jarrett
A precise high resistance comparison was performed between the traveling dual source bridge developed by the National Metrology Institute of Japan (NMIJ) and the adapted Wheatstone bridge of the National Institute of Standards and Technology (NIST) from 10 MΩ to 100 TΩ at NIST. The NMIJ traveling bridge was shipped to NIST Gaithersburg and was installed right next to the NIST bridge and these bridges alternately measured the resistance ratio of the high resistance standards, without moving the location of the resistors inside the temperature controlled air-bath. Having the bridges and resistance standards in the same location for the comparison decreased the transportation and temperature coefficient effects on the resistance standards, contributing to the excellent agreement of the measured values. The NMIJ traveling bridge used an 8.5-digit digital multimeter and a relay switch box to determine a resistance ratio by measuring the ratio of the voltages applied to the resistors. The comparison was started from 10 MΩ based on the same 1 MΩ standard resistor calibrated using a NIST two-terminal cryogenic current comparator bridge, and standard resistors from 10 MΩ to 100 TΩ were calibrated by repeating 10:1 scaling measurements with both systems. Excellent agreement was obtained within the uncertainty of all resistance ranges and the difference between both systems was less than 1 μΩ Ω−1 up to 1 TΩ and the degrees of equivalence for 10 TΩ and 100 TΩ were less than 6 μΩ Ω−1.