18 July 2019 in IEEE Transactions on Electron Devices
In this paper, we show that quantum Hall resistance measurements using two terminals may be as precise as four-terminal measurements when applying superconducting split contacts. The described sample designs eliminate resistance contributions of terminals and contacts such that the size and complexity of next-generation quantized Hall resistance devices can be significantly improved.
10 December 2018 in IEEE Transactions on Instrumentation and Measurement
We report the performance of a quantum Hall resistance standard based on epitaxial graphene maintained in a 5-T tabletop cryocooler system. This quantum resistance standard requires no liquid helium and can operate continuously, allowing year-round accessibility to quantized Hall resistance measurements. The ν = 2 plateau, with a value of R K /2, also seen as R H , is used to scale to 1 kQ using a binary cryogenic current comparator (BCCC) bridge and a direct current comparator (DCC) bridge. The uncertainties achieved with the BCCC are such as those obtained in the state-of-the-art measurements using GaAs-based devices. BCCC scaling methods can achieve large resistance ratios of 100 or more, and while room temperature DCC bridges have smaller ratios and lower current sensitivity, they can still provide alternate resistance scaling paths without the need for cryogens and superconducting electronics. Estimates of the relative uncertainties of the possible scaling methods are provided in this report, along with a discussion of the advantages of several scaling paths. The tabletop system limits are addressed as are potential solutions for using graphene standards at higher currents.
3 February 2021 in Physical Review B
As first recognized in 2010, epitaxial graphene on SiC(0001) provides a platform for quantized Hall resistance (QHR) metrology unmatched by other two-dimensional structures and materials. Here we report graphene parallel QHR arrays, with metrologically precise quantization near . These arrays have tunable carrier densities, due to uniform epitaxial growth and chemical functionalization, allowing quantization at the robust filling factor in array devices at relative precision better than . Broad tunability of the carrier density also enables investigation of the plateau. Optimized networks of QHR devices described in this work suppress Ohmic contact resistance error using branched contacts and avoid crossover leakage with interconnections that are superconducting for quantizing magnetic fields up to 13.5 T. Our work enables more direct scaling of resistance for quantized values in arrays of arbitrary network geometry.
8 February 2016 in Journal of Microscopy
Summary: Transmission electron microscopy (TEM) provides sub‐nanometre‐scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. We describe micro‐CT scouting for TEM that allows noninvasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench‐top micro‐CT scanner with 10 μm resolution was used to determine the location of patches of the mucous membrane in osmium‐stained human nasal scraping samples. Once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra‐thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometre resolution. This method substantially reduced the time and labour of the search process from typically 20 sections for light microscopy to three sections with no added sample preparation.
28 June 2023 in IEEE Transactions on Instrumentation and Measurement
Advances in the development of graphene-based technology have enabled improvements in DC resistance metrology. Devices made from epitaxially grown graphene have replaced the GaAs-based counterparts, leading to an easier and more accessible realization of the ohm. By optimizing the scale of the growth, it has become possible to fabricate quantized Hall array resistance standards (QHARS) with nominal values between 1 kΩ and 1.29 MΩ. One of these QHARS device designs accommodates a value of about 1.01 MΩ, which made it an ideal candidate to pursue a proof-of-concept that graphene-based QHARS devices are suitable for forming wye-delta resistance networks. In this work, the 1.01 MΩ array output nearly 20.6 MΩ due to the wye-delta transformation, which itself is a special case of star-mesh transformations. These mathematical equivalence principles allow one to extend the QHR to the 100 MΩ and 10 GΩ resistance levels with fewer array elements than would be necessary for a single array with many more elements in series. The 1.01 MΩ device shows promise that the wye-delta transformation can shorten the calibration chain, and, more importantly, provide a chain with a more direct line to the quantum SI.
9 October 2023 in Applied Physics Letters
A mathematical approach is adopted for optimizing the number of total device elements required for obtaining high effective quantized resistances in graphene-based quantum Hall array devices. This work explores an analytical extension to the use of star–mesh transformations such that fractal-like, or recursive, device designs can yield high enough resistances (like 1 EΩ, arguably the highest resistance with meaningful applicability) while still being feasible to build with modern fabrication techniques. Epitaxial graphene elements are tested, whose quantized Hall resistance at the ν=2 plateau (RH≈ 12 906.4 Ω) becomes the building block for larger effective, quantized resistances. It is demonstrated that, mathematically, one would not need more than 200 elements to achieve the highest pertinent resistances.