Rachmawati

Rachmawati

Auto-generated profile, based on publicly available information

Rachmawati

School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Jalan Ganesa 10, Bandung, 40132

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
RARachmawati
Rachmawati
HKHiroki Kojima
Hiroki Kojima
KKKatsumi Kato
Katsumi Kato
NZNabila Zebouchi
Nabila Zebouchi
NHNaoki Hayakawa
Naoki Hayakawa
Functionally graded materials (FGM) application with graded permittivity and conductivity is promising as an effective technique for electric field relaxation in SF6 gas around HVDC gas insulated switchgear (GIS)/gas insulated transmission line (GIL) spacers. To approach the practical application of FGM to HVDC GIS/GIL spacers, this article investigates the electric field reduction effect given by permittivity and conductivity graded materials ( $\varepsilon /\sigma $ -FGM) based on actual measured permittivity ( $\varepsilon $ ) characteristics of SrTiO3-filled epoxy composites and conductivity ( $\sigma $ ) characteristics of SiC-filled epoxy composites. In addition, theoretical discharge inception voltage (TDIV) of $\varepsilon /\sigma $ -FGM spacer is calculated under standard lightning impulse (LI) voltage based on the volume–time theory. The results show that the $\varepsilon /\sigma $ -FGM spacer with grading to lower permittivity (GLP) ( $\varepsilon _{r}$ from 12.7 to 4) containing 0–26.9-vol% SrTiO3-filled epoxy composite and U-shaped graded conductivity containing 5–10-vol% SiC-filled epoxy composite is effective for electric field relaxation under DC steady state (DC-SS) and LI voltage where both resistive and capacitive fields present. It is attributed to the higher $\varepsilon $ and $\sigma $ of FGM spacer near the HV conductor/spacer interface. TDIV under LI voltage is also estimated to be 26% higher at 0.5 MPa-abs, compared with the conventional spacer without $\varepsilon /\sigma $ grading.

1 February 2024 in Emerging Science Journal
Verified
Journal Article
Open access
PDF file
ABAdjie Bagaskara
Adjie Bagaskara
RARachmawati
Rachmawati
SUSuwarno
Suwarno
The performance of outdoor insulators in transmission lines may deteriorate due to aging and can even be enhanced by the presence of pollutants. Leakage current (LC) measurement is one of the most effective methods to diagnose the insulator condition, utilizing LC parameters such as magnitude and total harmonic distortion (THD). However, research on the interpretation of these parameters is still limited. This paper discusses the diagnostic method by simulation, employing the LC equivalent circuits of different types of insulators and examining the influence of environmental factors, such as humidity and pollutant levels. LC waveforms are first obtained through experiments on various insulator types, including traditional ceramic and glass insulators, advanced composite insulators, or the hybrid type of RTV silicone rubber-coated and conducting glazed insulators. Subsequently, simulations on the LC circuits of Suwarno’s and Kizilcay’s models are performed to obtain similar LC waveforms and properties. The values of the equivalent circuit parameters are then used to diagnose each insulator’s characteristics and environmental effects. The results indicate that composite insulators of epoxy resin or SiR have a larger intrinsic resistance of ~40 GΩ and nonlinear resistance (a few MΩ to tens of GΩ), representing high surface resistance of the insulators against water and pollutants. A comparison of these parameters is expected to indicate the severity levels of insulator condition. Doi: 10.28991/ESJ-2024-08-01-022 Full Text: PDF

20 October 2024
Verified
Conference Paper
Closed access
RARachmawati
Rachmawati
AAAulia Ramadhana Alifianda
Aulia Ramadhana Alifianda
ANAgustinus Danu Nalendra
Agustinus Danu Nalendra
FPFitri Aulia Permatasari
Fitri Aulia Permatasari
SSSuwarno Suwarno
Suwarno Suwarno
In Indonesia, high-voltage outdoor insulators are subjected to harsh environmental conditions, such as intense UV radiation, high temperatures, and coastal salt pollution. This study investigates the use of nSiO 2 -filled room temperature vulcanized (RTV) silicone rubber (SiR) coatings on ceramic insulators to increase their hydrophobicity and reduce leakage current. This paper reports the impacts of various nSiO 2 concentrations on permittivity, dielectric dissipation factor, and hydrophobicity. The results show that a 3 wt% nSiO 2 -filled RTV SiR coating achieves the highest contact angle, indicating optimal hydrophobic characteristic, along with improved permittivity with lower dielectric loss. Subsequent leakage current tests on insulators covered with this optimized composition under artificial environmental conditions confirmed a considerable reduction in leakage current as compared to the uncoated insualtor. This study confirms that nSiO 2 -filled RTV SiR coatings can considerably improve the performance of high-voltage insulators, providing significant enhancements in electrical insulation for HV applications.

19 December 2025 in e-Prime – Nexus of Electrical, Electronic, and Intelligent Engineering
Verified
Journal Article
Open access
RMRifky Pramudita Mahendra
Rifky Pramudita Mahendra
RARachmawati
Rachmawati
SUSuwarno
Suwarno
FPFitri Aulia Permatasari
Fitri Aulia Permatasari
VSVeinardi Suendo
Veinardi Suendo