Yılmaz Güvercin

Yılmaz Güvercin

Auto-generated profile, based on publicly available information

Yılmaz Güvercin

Department of Orthopaedic and Traumatology Trabzon Kanuni Training and Research Hospital Trabzon Turkey

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2025 in Orthopaedic Surgery
Verified
Journal Article
Open access
YGYılmaz Güvercin
Yılmaz Güvercin
MYMURAT YAYLACI
MURAT YAYLACI
ADAyberk Dizdar
Ayberk Dizdar
MÖMehmet Emin Özdemir
Mehmet Emin Özdemir
SASevil Ay
Sevil Ay
GPGökhan Peker
Gökhan Peker
Objective: Despite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.Method: FNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM). This study created a solid model with images of femur bone tomography. Dynamic hip screws (DHS), cannulated screws (CCS), and medial buttress plates (MBP) were obtained by making three‐dimensional designs. The required elements for the models were assigned, and the material properties of the elements were defined. The solutions were obtained as crack distance and deformation results after defining the boundary conditions and applying the necessary loading.Results: The strain and crack distance values created by six models on the fracture line under different parameters were obtained, and the numerical results were evaluated. The DHS and CCS models produced the highest crack distance and deformation values when all screws were loose. The lowest values were obtained in the intact‐85 model when all CCS were tight. When the results are evaluated, it is seen that the MBP has a decreasing effect on the results. Mechanical evaluation of six different options used in femoral neck fractures was performed. 85 mm CCS applied to our standard model gave the best results, while the use of 80 mm CCS in the same model showed promising results compared to other models. It is understood that CCS have the best stability even in loosening models with the medial support plate. Different models are from intact‐85 mm DHS+1CS+MBP to DHS+1CS, which was worked with LSR+USR‐2, according to decreasing stability.Conclusion: This study offers various biomechanical solutions to possible intraoperative problems in FNF treatment. The following results were obtained from the study data. When the CCS needs to be lengthened or replaced, it is appropriate to use the CCS with the MBP. A single anti‐rotation screw is sufficient for lag screw extensions of the DHS plate, and the MBP may be a savior procedure in surgery.

1 February 2016 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
PDF file
AEAdem Erkut
Adem Erkut
LTLevent TUMKAYA
Levent TUMKAYA
MBMehmet Sabri Balik
Mehmet Sabri Balik
YKYildiray Kalkan
Yildiray Kalkan
YGYilmaz Guvercin
Yilmaz Guvercin
ISIbrahim Sehitoglu
Ibrahim Sehitoglu
Key words: Electromagnetic Fields; Calcineurin; Bone Development; Muscle Cells; Rats

29 December 2020 in International Journal of Engineering and Applied Sciences
Verified
Journal Article
Closed access
PDF file
GNGözde Nur Ni̇şAnci̇
Gözde Nur Ni̇şAnci̇
YGYılmaz Güverci̇n
Yılmaz Güverci̇n
SASabit Melih Ateş
Sabit Melih Ateş
HÖHasan Ölmez
Hasan Ölmez
EYEcren Uzun Yaylacı
Ecren Uzun Yaylacı
MYMURAT YAYLACI
MURAT YAYLACI
Dental implant applications for edentulous jaws are today considered a predictable, safe, and daily technique for giving patients new aesthetics and function. However, the success of the implant therapy should be thoroughly investigated for long-term clinical results about the stress distribution in hosting bone tissue and prosthetic components. In this study, the effect of different prosthesis designs on the stress distribution around the abutment and dental implant in bone tissue was investigated using the finite element method (FEM) with Workbench module of the ANSYS package program. The examination focuses on the effect of the number of implants in teeth layouts on the distribution of stresses, strains, and displacements. In the study the historical development of dental implant problems is mentioned, and some previous studies are summarized. Critical information is also given about biomechanics, dental implants, jawbone, teeth, and the finite element method. Totally four different cases, one layout with three implants and three layouts with two implants, were analyzed. Titanium was used as an implant and abutment material. Nobel Active implants and abutments manufactured by Nobel BioCare Company were used for complete toothless lower jaw case. The critical stress, strain, and displacement values were determined for all four different scenarios. As a result, it was concluded that stresses, strains, and displacements have lower values for the design of triple dental implants compared to other layouts.

28 August 2025 in Applied Ocean Research
Verified
Journal Article
Open access
OÖOrkun Burak Öztürk
Orkun Burak Öztürk
ŞKŞaban Emre Kartal
Şaban Emre Kartal
İTİdris Turna
İdris Turna
APAhmet Emre Pirim
Ahmet Emre Pirim
ZKZafer Kurt
Zafer Kurt
MYMURAT YAYLACI
MURAT YAYLACI

31 December 2021 in Journal of Anatolian Environmental and Animal Sciences
Verified
Journal Article
Closed access
YGYılmaz Güverci̇n
Yılmaz Güverci̇n
MYMURAT YAYLACI
MURAT YAYLACI
İnsan ve hayvan sağlığı araştırmalarında sonlu elemanlar yöntemi (SEY) kullanılarak gerçekleştirilen analiz çalışmaları, bilgisayar teknolojisinin de gelişmesiyle birlikte önem kazanmıştır. SEY analiz çalışmaları fare, köpek, tavşan, domuz, at ve koyun gibi hayvanlarda yapılmaktadır. Bu hayvanlarda bulunan kemiklerin modelleme çalışmaları büyük hayvanlarda yapılması daha doğru sonuçlar vermektedir. Bu çalışmanın amacı, insan ve koyun femurununlarının katı modellemelerinin oluşturulup, sonlu elemanlar yöntemi kullanılarak bir paket program yardımıyla gerilme, şekil değiştirme ve deformasyon değerlerinin karşılaştırılmasıdır. Analizler sonucunda koyun femurundaki mekanik değerlerin insan femurundakilere kıyasla daha düşük olduğu tespit edilmiştir.

1 May 2023 in Journal of Clinical and Analytical Medicine
Verified
Journal Article
Open access
AAAhmet atilla Abdioğlu
Ahmet atilla Abdioğlu
YGYılmaz Güvercin
Yılmaz Güvercin