Mohd Shahrir Mohd Sani

Mohd Shahrir Mohd Sani

Auto-generated profile, based on publicly available information

Mohd Shahrir Mohd Sani

Advanced Structural Integrity and Vibration Research Group (ASIVR), Fakulti Teknologi Kejuruteraan Mekanikal & Automotif, Universiti Malaysia Pahang Al-Sultan Abdullah, 26600 Pekan, Pahang, Malaysia

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Science of The Total Environment
Verified
Journal Article
Closed access
EEErdiwansyah Erdieansyah
Erdiwansyah Erdieansyah
RMRizalman Mamat
Rizalman Mamat
MSM.S.M. Sani
M.S.M. Sani
KSK. Sudhakar
K. Sudhakar

22 December 2015 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
NAN A Z Abdullah
N A Z Abdullah
MSM S M Sani
M S M Sani
MRMd Mustafizur Rahman
Md Mustafizur Rahman
IZI Zaman
I Zaman
This paper is a review of information and related studies concerning topic of model updating in structural dynamics. It is purposed to introduce and explain the important concept of the discussed subject in model updating area as well as to summarize the development and available guidance and method of conducting the study in this area. The review is structured by presenting an overview of general concept of finite element model updating in structural dynamics and the capabilities of finite element method as a tool in model updating. After the concept introduction, the reliable methodology to perform model updating, the limitation and the critical issues in model updating is discussed. The limitation and problems arise concerning correcting inaccurate finite element model is also discussed. This lead to issue of parameterization and regularization which the limitation and uncertainty in choosing the updating parameter is shown able to be overcome. Further studies on the elimination of systematic errors from both the measurements and the finite element model so that it can provide more reliable model updating is recommended.

20 December 2016 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
SZSiti Norazila Zahari
Siti Norazila Zahari
MSMohd Shahrir Mohd Sani
Mohd Shahrir Mohd Sani
MIMahadzir Ishak
Mahadzir Ishak
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry

31 October 2014 in Applied Mechanics and Materials
Verified
Journal Article
Closed access
PDF file
IZIzzuddin Bin Zaman
Izzuddin Bin Zaman
MSMuhammad Mohamed Salleh
Muhammad Mohamed Salleh
MIMaznan Bin Ismon
Maznan Bin Ismon
BMBukhari Manshoor
Bukhari Manshoor
KKKhalid A Khalid
Khalid A Khalid
SASherif Araby
Sherif Araby
Structural vibration is undesirable, wasting energy and possibly leading to excessive deflections and structure and machine’s failure. In order to reduce structural vibration, one of the common way is considering vibration absorber system attach to the structure. In this study, a vibration absorber is developed in a small scale size. The host structure selected for the study is a fixed-fixed ends beam. The effectiveness of vibration absorbers attached to a beam is investigated through experimental study. In prior to experiment, a finite element analysis of Solidworks® and analytical equations of Matlab® are produced in order to determine the structural dynamic response of the beam, such as the natural frequency and mode shapes. The preliminary results of finite element analysis demonstrate that the first five natural frequency of fixed-fixed end beam are 17Hz, 46Hz, 90Hz, 149Hz and 224Hz, and these results are in agreement with the beam’s analytical equations. However, there are slight discrepancies in experiment result due to noise and error occurred during the setup. In the later stage, the experimental works of beam are performed with attached vibration absorber. Result shows that the attachment of vibration absorber produces better outcome, which is about 45% vibration reduction. It is expected that by adding more vibration absorber to the structure, the vibration attenuation can significant.

16 November 2016 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
MSM.S.M. Sani
M.S.M. Sani
NAN.A.Z. Abdullah
N.A.Z. Abdullah
SZS.N. Zahari
S.N. Zahari
JSJ.P. Siregar
J.P. Siregar
MRMd Mustafizur Rahman
Md Mustafizur Rahman
Model updating is a process of making adjustment of certain parameters of finite element model in order to reduce discrepancy between analytical predictions of finite element (FE) and experimental results. Finite element model updating is considered as an important field of study as practical application of finite element method often shows discrepancy to the test result. The aim of this research is to perform model updating procedure on a composite structure as well as trying improving the presumed geometrical and material properties of tested composite structure in finite element prediction. The composite structure concerned in this study is a plate of reinforced kenaf fiber with epoxy. Modal properties (natural frequency, mode shapes, and damping ratio) of the kenaf fiber structure will be determined using both experimental modal analysis (EMA) and finite element analysis (FEA). In EMA, modal testing will be carried out using impact hammer test while normal mode analysis using FEA will be carried out using MSC. Nastran/Patran software. Correlation of the data will be carried out before optimizing the data from FEA. Several parameters will be considered and selected for the model updating procedure.

20 December 2016 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
MIM.H.N. Izham
M.H.N. Izham
NAN.A.Z. Abdullah
N.A.Z. Abdullah
SZS.N. Zahari
S.N. Zahari
MSM.S.M. Sani
M.S.M. Sani
Frame structure is widely used in many engineering structures. Besides, vibrational problem is one of the main challenges in industry. Bolted joints are commonly used in industry to connect two or more mechanical parts and it plays a significant role in the dynamics characteristic of the structure. This study aims to perform a model updating procedure on a portal frame structure which consists of bolted joints. Modal parameters such as the natural frequencies, mode shapes and damping ratios are gathered through finite element analysis (FEA) and experimental modal analysis (EMA). Frame structure is set to be fixed-free boundary condition and equivalence of nodes is performed at the area of bolted joints. Correlation between these two sets of data is carried out. With the selected parameters identified to perform model updating on the structure by using sensitivity analysis, the discrepancies in natural frequencies were reduced between FEA and EMA.