21 April 2022 in IEEE Transactions on Biomedical Engineering
Objective: To develop a system for training central venous catheterization that does not require an expert observer. We propose a training system that uses video-based workflow recognition and electromagnetic tracking to provide trainees with real-time instruction and feedback. Methods: The system provides trainees with prompts about upcoming tasks and visual cues about workflow errors. Most tasks are recognized from a webcam video using a combination of a convolutional neural network and a recurrent neural network. We evaluated the system's ability to recognize tasks in the workflow by computing the percent of tasks that were recognized and the average signed transitional delay between the system and reviewers. We also evaluated the usability of the system using a participant questionnaire. Results: The system was able to recognize 86.2% of tasks in the workflow. The average signed transitional delay was −0.7s. The average usability score on the questionnaire was 4.7 out of 5 for the system overall. The participants found the interactive task list to be the most useful component of the system with an average score of 4.8 out of 5. Conclusion: Overall, the participants’ response to the system was positive. Participants perceived that the system would be useful for central venous catheterization training. Our system provides trainees with meaningful instruction and feedback without needing an expert observer to be present. Significance: We are able to provide trainees with more opportunities to access instruction and meaningful feedback by using workflow recognition.
25 April 2025 in International Journal of Computer Assisted Radiology and Surgery
14 December 2024 in Healthcare Technology Letters
Percutaneous nephrostomy can be an effective means of preventing irreparable renal damage from obstructive renal disease thereby providing patients with more time to access treatment to remove the source of the blockage. In sub‐Saharan Africa, where there is limited access to treatments such as dialysis and transplantation, a nephrostomy can be life‐saving. Training this procedure in simulation can allow trainees to develop their technical skills without risking patient safety, but still requires an ex‐pert observer to provide performative feedback. In this study, the feasibility of using video as an accessible method to assess skill in simulated percutaneous nephrostomy is evaluated. Six novice urology residents and six expert urologists from Ouakam Military Hospital in Dakar, Senegal performed 4 nephrostomies each using the setup. Motion‐based metrics were computed for each trial from the predicted bounding boxes of a trained object detection network, and these metrics were compared between novices and experts. The authors were able to measure significant differences in both ultrasound and needle handling between novice and expert participants. Additionally, performance changes could be measured within each group over multiple trials. Conclusions: Video‐based skill assessment is a feasible and accessible option for providing trainees with quantitative performance feedback in sub‐Saharan Africa.
13 July 2026 in Journal of Surgical Education
(1) To establish the feasibility of novice learners building inguinal hernia models for simulation-based training in open inguinal hernia repairs (IHR). (2) To examine the associations between participation in model building and learners' self-reported confidence in understanding of the inguinal canal anatomy, the anatomic accuracy of learner-constructed models, and technical performance during a simulated open IHR. We hypothesized that learner-led model construction is feasible, supports acquisition of relevant anatomy knowledge, and improves performance in some steps of a simulated open IHR. Prospective randomized controlled trial. Queen's University, Kingston, Ontario, Canada; institutional academic training environment. Forty-eight novice learners (second-year medical students) with minimal prior exposure to open or laparoscopic IHR were enrolled and randomly assigned to a didactic lecture-only group (control) or to a didactic lecture and learner-led model-building group (intervention). All study participants were then asked to complete a simulated open IHR procedure. Self-reported confidence in understanding of the 3-dimensional anatomy of the inguinal canal, as well as procedural and executional errors were assessed. Learner-constructed models were anatomically accurate and suitable for use in simulation-based training, and participants rated the model-building activity positively. Participants in the model-building (intervention) group demonstrated greater gains in self-reported confidence in the understanding of the 3-dimensional anatomy of the inguinal canal compared to participants in the control group (p = 0.004). Participants in the model-building (intervention) group committed fewer executional errors during external oblique aponeurosis exposure (p = 0.03), fewer procedural errors during wound closure (p = 0.05), and were more likely to complete hernia sac resection within the allotted time (p = 0.04). Learner-led construction of simulated models is a feasible, low-cost approach for simulation-based training in open IHR. This intervention improves learners' self-reported understanding of the inguinal canal anatomy and is associated with improved performance in some steps of a simulated open IHR, while requiring minimal materials and instructional resources.