Heinrich M. J. Janzing

Heinrich M. J. Janzing

Auto-generated profile, based on publicly available information

Heinrich M. J. Janzing

VieCuri Medical Center, Venlo, the Netherlands

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2011 in Cochrane Database of Systematic Reviews
Verified
Journal Article
Closed access
PDF file
IWIngrid Mha Wilms
Ingrid Mha Wilms
DHDominique Enm de Hoog
Dominique Enm de Hoog
DVDianne C de Visser
Dianne C de Visser
HJHeinrich Mj Janzing
Heinrich Mj Janzing

2 February 2018 in BMC Surgery
Verified
Journal Article
Open access
PDF file
PKPishtiwan H. S. Kalmet
Pishtiwan H. S. Kalmet
GMGuido Meys
Guido Meys
YHYvette Y. V. Horn
Yvette Y. V. Horn
SESilvia M. A. A. Evers
Silvia M. A. A. Evers
HSHenk A. M. Seelen
Henk A. M. Seelen
PBPeter R. G. Brink
Peter R. G. Brink
The standard aftercare treatment in surgically treated trauma patients with fractures around or in a joint, known as (peri)- or intra-articular fractures of the lower extremities, is either non-weight bearing or partial weight bearing. We have developed an early permissive weight bearing post-surgery rehabilitation protocol in surgically treated patients with fractures of the lower extremities. In this proposal we want to compare our early permissive weight bearing protocol to the existing current non-weight bearing guidelines in a prospective comparative cohort study. The study is a prospective multicenter comparative cohort study in which two rehabilitation aftercare treatments will be contrasted, i.e. permissive weight bearing and non-weight bearing according to the AO-guideline. The study population consists of patients with a surgically treated fracture of the pelvis/acetabulum or a surgically treated (peri)- or intra-articular fracture of the lower extremities. The inclusion period is 12 months. The duration of follow up is 6 months, with measurements taken at baseline, 2,6,12 and 26 weeks post-surgery. Primary outcome measure: ADL with Lower Extremity Functional Scale. Outcome variables for compliance, as measured with an insole pressure measurement system, encompass peak load and step duration. This study will investigate the (cost-) effectiveness of a permissive weight bearing aftercare protocol. The results will provide evidence whether a permissive weight bearing protocol is more effective than the current non-weight bearing protocol. The study is registered in the Dutch Trial Register ( NTR6077 ). Date of registration: 01–09-2016.

1 December 2020 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
LVLisanne Vranken
Lisanne Vranken
IBIrma J.A. de Bruin
Irma J.A. de Bruin
JDJohanna H M Driessen
Johanna H M Driessen
PGPiet P.M. Geusens
Piet P.M. Geusens
JEJohn A Eisman
John A Eisman
CWCaroline E. Wyers
Caroline E. Wyers
Fracture liaison services (FLS) are considered to be the most effective organizational approach for secondary fracture prevention. In this study, we evaluated whether FLS care was associated with reduced subsequent fracture and mortality risk over 3 years of follow-up. In total, 8682 consecutive patients aged 50–90 years with a recent fracture were included. Before FLS introduction, regular fracture treatment procedures were followed (pre-FLS). After FLS introduction, patients were invited to the FLS and FLS attenders were assessed for osteoporosis, prevalent vertebral fractures, metabolic bone disorders, medication use, and fall risk, and treatment for fracture prevention was initiated according to Dutch guidelines. All fractures were radiographically confirmed and categorized into major/hip (pelvis, proximal humerus or tibia, vertebral, multiple rib, distal femur) and non-major/non-hip (all other fractures). Mortality risk was examined using age and sex adjusted Cox proportional hazard models. For subsequent fracture risk, Cox proportional hazard models were adjusted for age, sex, and competing mortality risk (subdistribution hazard [SHR] approach). The pre-FLS group consisted of 2530 patients (72% women), of whom 1188 (46.9%) had major/hip index fractures, the post-FLS group consisted of 6152 patients (69% women), of whom 2973 (48.3%) had major/hip index fractures. In patients with a non-major/non-hip fracture there was no difference in subsequent non-major/non-hip fracture risk or mortality between pre-FLS and post-FLS. In patients with a major/hip index fracture, mortality risk was lower post-FLS (hazard ratio [HR] 0.84; 95% confidence interval [CI], 0.73–0.96) and subsequent major/hip fracture risk was lower in the first 360 days after index fracture post-FLS compared to pre-FLS (SHR 0.67; 95% CI, 0.52–0.87). In conclusion, FLS care was associated with a lower mortality risk in the first 3 years and a lower subsequent major/hip fracture risk in the first year in patients with a major/hip index fracture but not in patients with a non-major/non-hip fracture. © 2022 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).

22 November 2007 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Closed access
PDF file
HJHeinrich M. J. Janzing
Heinrich M. J. Janzing

18 August 2020 in 3D Printing in Medicine
Verified
Journal Article
Open access
PDF file
HJH. M. J. Janzing
H. M. J. Janzing
SBS. A. M. Bessems
S. A. M. Bessems
MLM. A. P. Ligthart
M. A. P. Ligthart
ELEsther Van Lieshout
Esther Van Lieshout
HTH. P. Theeuwes
H. P. Theeuwes
MVM. H. J. Verhofstad
M. H. J. Verhofstad
Background: The aim of this work was to develop a three-dimensionally (3D) printed brace for the acute treatment of dorsally dislocated and correctly reduced distal radius fractures (DRF). The hypothesis was that a brace shaped to the mirror image of the contralateral (non-fractured) wrist will have an optimal anatomical fit, resulting in improved comfort and lower rates of secondary fracture displacement. Method: Validation: the circumference of both wrists and comfort of the brace were studied in healthy volunteers and effectiveness of the brace was evaluated in an ex vivo fracture model. Clinical study: the brace was tested for comfort and effectiveness in patients with a well reduced unstable DRF. Results: Validation: the circumference of both wrists may be different, the brace retained the reduction in the ex vivo fracture model and was well tolerated in the volunteers. Clinical study: in DRF patients comfort scores were lower and pain scores higher compared to the healthy volunteers. After 3 and 5 weeks all patients were independent in ADL according to the Katz-index. Posttraumatic swelling subsided in the first week. In two of the five patients secondary fracture dislocation occurred. Conclusions: Treatment of a dislocated DRF in the acute setting (day one) with a custom-made 3D printed brace, anatomically modelled from a 3D scan of the contralateral wrist, is possible. Difference between both wrists and posttraumatic swelling must be adapted for. The high rate of secondary fracture displacement led to early discontinuation of the study and a small sample size. Trial registration: Name of the registry: ClinicalTrials.Gov Trial registration number: NCT03848702 Date of registration: 02/21/2019, retrospectively registered

20 October 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
ADA.M. Daniels
A.M. Daniels
MBM.S.A.M. Bevers
M.S.A.M. Bevers
SSS. Sassen
S. Sassen
CWCaroline E. Wyers
Caroline E. Wyers
BRBert van Rietbergen
Bert van Rietbergen
HJH.M.J. Janzing
H.M.J. Janzing
Background: Computed tomography (CT), magnetic resonance imaging, and bone scintigraphy are second-line imaging techniques that are frequently used for the evaluation of patients with a clinically suspected scaphoid fracture. However, as a result of varying diagnostic performance results, no true reference standard exists for scaphoid fracture diagnosis. We hypothesized that the use of high-resolution peripheral quantitative CT (HR-pQCT) in patients with a clinically suspected scaphoid fracture could improve scaphoid fracture detection compared with conventional CT in the clinical setting. Methods: The present study included 91 consecutive patients (≥18 years of age) who presented to the emergency department with a clinically suspected scaphoid fracture between December 2017 and October 2018. All patients were clinically reassessed within 14 days after first presentation, followed by CT and HR-pQCT. If a scaphoid fracture was present, the fracture type was determined according to the Herbert classification system and correlation between CT and HR-pQCT was estimated with use of the Kendall W statistic or coefficient of concordance (W) (the closer to 1, the higher the correlation). Results: The cohort included 45 men and 46 women with a median age of 52 years (interquartile range, 29 to 67 years). HR-pQCT revealed a scaphoid fracture in 24 patients (26%), whereas CT revealed a scaphoid fracture in 15 patients (16%). Patients with a scaphoid fracture were younger and more often male. The correlation between CT and HR-pQCT was high for scaphoid fracture type according to the Herbert classification system (W = 0.793; 95% confidence interval [CI], 0.57 to 0.91; p < 0.001) and very high for scaphoid fracture location (W = 0.955; 95%, CI 0.90 to 0.98; p < 0.001). Conclusions: In the present study, the number of patients diagnosed with a scaphoid fracture was 60% higher when using HR-pQCT as compared with CT. These findings imply that a substantial proportion of fractures—in this study, more than one-third—will be missed by the current application of CT scanning in patients with a clinically suspected scaphoid fracture. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.