Amir H. Golnabi

Amir H. Golnabi

Auto-generated profile, based on publicly available information

Amir H. Golnabi

Montclair State University

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in JAMA Pediatrics
Verified
Journal Article
Open access
PDF file
CPCourtney Peterson
Courtney Peterson
HSHaiyan Su
Haiyan Su
DTDiana M. Thomas
Diana M. Thomas
MHMoonseong Heo
Moonseong Heo
AGAmir H. Golnabi
Amir H. Golnabi
SHSteven B. Heymsfield
Steven B. Heymsfield
A large international effort is underway to reduce childhood obesity in response to increasing rates of obesity among children and adolescents.1-3 Accurate classification of excess body fat is central to these efforts. As of 2017, body mass index (BMI), calculated as weight in kilograms divided by height in meters squared, is used worldwide to screen for obesity.

1 December 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
PMPaul Meaney
Paul Meaney
DGDouglas Goodwin
Douglas Goodwin
AGAmir H. Golnabi
Amir H. Golnabi
TZTian Zhou
Tian Zhou
MPMatthew Pallone
Matthew Pallone
KPKeith D. Paulsen
Keith D. Paulsen
We have acquired 2-D and 3-D microwave tomographic images of the calcaneus bones of two patients to assess correlation of the microwave properties with X-ray density measures. The two volunteers were selected because each had one leg immobilized for at least six weeks during recovery from a lower leg injury. A soft-prior regularization technique was incorporated with the microwave imaging to quantitatively assess the bulk dielectric properties within the bone region. Good correlation was observed between both permittivity and conductivity and the computed tomography-derived density measures. These results represent the first clinical examples of microwave images of the calcaneus and some of the first 3-D tomographic images of any anatomical site in the living human.

1 January 2012 in International Journal of Biomedical Imaging
Verified
Journal Article
Open access
PDF file
PMPaul Meaney
Paul Meaney
TZTian Zhou
Tian Zhou
DGDouglas Goodwin
Douglas Goodwin
AGAmir Golnabi
Amir Golnabi
EAElia A. Attardo
Elia A. Attardo
KPKeith D. Paulsen
Keith D. Paulsen
A critical need exists for new imaging tools to more accurately characterize bone quality beyond the conventional modalities of dual energy X-ray absorptiometry (DXA), ultrasound speed of sound, and broadband attenuation measurements. In this paper we investigate the microwave dielectric properties of ex vivo trabecular bone with respect to bulk density measures. We exploit a variation in our tomographic imaging system in conjunction with a new soft prior regularization scheme that allows us to accurately recover the dielectric properties of small, regularly shaped and previously spatially defined volumes. We studied six excised porcine bone samples from which we extracted cylindrically shaped trabecular specimens from the femoral heads and carefully demarrowed each preparation. The samples were subsequently treated in an acid bath to incrementally remove volumes of hydroxyapatite, and we tested them with both the microwave measurement system and a micro-CT scanner. The measurements were performed at five density levels for each sample. The results show a strong correlation between both the permittivity and conductivity and bone volume fraction and suggest that microwave imaging may be a good candidate for evaluating overall bone health.

12 September 2013 in Medical Physics
Verified
Journal Article
Closed access
PMPaul Meaney
Paul Meaney
AGAmir H. Golnabi
Amir H. Golnabi
NENeil R. Epstein
Neil R. Epstein
SGShireen D. Geimer
Shireen D. Geimer
MFMargaret W. Fanning
Margaret W. Fanning
KPKeith D. Paulsen
Keith D. Paulsen

7 March 2013 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
AGAmir H. Golnabi
Amir H. Golnabi
PMPaul M. Meaney
Paul M. Meaney
KPKeith D. Paulsen
Keith D. Paulsen
We have implemented a soft prior regularization technique for microwave tomographic imaging that exploits spatial prior information from alternative imaging modalities. We have previously demonstrated in both simulation and phantom experiments that this approach is capable of improved property recovery compared with our conventional Tikhonov regularized method. An important concern with this type of integration is that the spatial information could be implemented in such a way as to overly influence or even bias the final results. For this reason, we have performed a rigorous quantitative analysis of this approach using both simulation and phantom experiments to investigate the sensitivity to inaccurate or even false spatial information. The majority of cases tested here involved simple targets to easily assess problems when the prior shapes are incorrect with respect to size and location or even when there is an extra target that does not exist in the actual imaging situation. In addition, we have also performed a simulated experiment utilizing anthropomorphic breast structural information to explore the capabilities in more challenging situations. The results are encouraging and demonstrate that the soft prior regularization can be a powerful tool, especially where the goal is specificity instead of sensitivity.

10 January 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
AGAmir H. Golnabi
Amir H. Golnabi
PMPaul Meaney
Paul Meaney
SGShireen Geimer
Shireen Geimer
KPKeith D. Paulsen
Keith D. Paulsen
Objective: Fusion of magnetic resonance imaging (MRI) breast images with microwave tomography is accomplished through a soft prior technique, which incorporates spatial information (from MRI), i.e., accurate boundary location of different regions of interest, into the regularization process of the microwave image reconstruction algorithm. Methods: Numerical experiments were completed on a set of three-dimensional (3-D) breast geometries derived from MR breast data with different parenchymal densities, as well as a simulated tumor to evaluate the performance over a range of breast shapes, sizes, and property distributions. Results: When the soft prior regularization technique was applied, both permittivity and conductivity relative root mean square error values decreased by more than 87% across all breast densities, except in two cases where the error decrease was only 55% and 78%. In addition, the incorporation of structural priors increased contrast between tumor and fibroglandular tissue by 59% in permittivity and 192% in conductivity. Conclusion:This study confirmed that the soft prior algorithm is robust in 3-D and can function successfully across a range of complex geometries and tissue property distributions. Significance: This study demonstrates that our microwave tomography is capable of recovering accurate tissue property distributions when spatial information from MRI is incorporated through soft prior regularization.