Jiannan Huang

Jiannan Huang

Auto-generated profile, based on publicly available information

Jiannan Huang

Department of Electrical and Computer Engineering, University of California at San Diego, La Jolla, CA 92093 USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JHJiannan Huang
Jiannan Huang
PMPatrick P. Mercier
Patrick P. Mercier
This article presents a high-dynamic-range (DR) voltage-controlled oscillator (VCO)-based front end for sensor readout applications. Unlike conventional VCO-based quantizers, which suffer from large voltage-to-frequency non-linearities, the proposed design leverages differential pulse-code modulation (DPCM) from compression theory to substantially reduce the amplitude of the signal incident to the VCO quantizer, thereby achieving an ultra-low total harmonic distortion (THD) of -112 dB. In addition, background digital gain calibration is employed to overcome gain deviation of the VCO, thus ensuring a robust design. Together with dynamic element matching (DEM), the techniques enable a high DR using only the first-order noise shaping inherent in VCO-based quantizers and a moderate 32x oversampling ratio. Fabricated in 65 nm, the sensor front end consumes 3.2-μW power and achieves an SNDR of 89 dB and a DR of 94 dB in 500 Hz of bandwidth. Together with a 1.18-μVrms integrated input-referred noise, it achieves a noise efficiency factor (NEF) of 4 and a Schreier FoM of 171 dB.

23 January 2019 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
JHJiannan Huang
Jiannan Huang
FLFarah Laiwalla
Farah Laiwalla
JLJihun Lee
Jihun Lee
LCLingxiao Cui
Lingxiao Cui
VLVincent Leung
Vincent Leung
PMPatrick P. Mercier
Patrick P. Mercier
This letter presents a miniaturized neural recording analog front-end (AFE) suitable for distributed sub-mm neural recording implants. Including reference generators, this AFE occupies an area of only 0.01 mm2, thanks to a mostly digital architecture with more than half of area being scalable digital logic. Implemented in 65 nm CMOS, the AFE is measured to consume 3.2 μW of power from 0.6 V supply, and achieves an input-referred noise of 2.2 μVrms over 500 Hz of bandwidth. The AFE is validated by integrating it into a neural sensing SoC with wireless power and data telemetry. In vitro experiments demonstrate reliable recording of the AFE in a fully wireless environment.

7 December 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
CPCorentin Pochet
Corentin Pochet
JHJiannan Huang
Jiannan Huang
PMPatrick Mercier
Patrick Mercier
DHDrew Hall
Drew Hall
This paper presents a second-order voltage-controlled oscillator (VCO)-based front-end for the direct digitization of biopotential signals. This work addresses the non-linearity of VCO-based ADC architectures with a mismatch resilient, multi-phase quantizer, a gated-inverted-ring oscillator (GIRO), achieving >110-dB SFDR. Leveraging the time-domain encoding of the first integrator, the ADC's power is dynamically scaled with the input amplitude enabling up to 35% power savings in the absence of motion artifacts or interference. An auxiliary input-impedance booster increases the ADC's input impedance to 50 MΩ across the entire bandwidth. Fabricated in a 65-nm CMOS process, this ADC achieves 92.3-dB SNDR in a 1 kHz BW while consuming 5.8 µW for a 174.7 dB Schreier FoM.

23 September 2021 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JHJiannan Huang
Jiannan Huang
PMPatrick P. Mercier
Patrick P. Mercier
This article presents a voltage-controlled oscillator (VCO)-based analog front end (AFE) for ExG readout applications with both a wide dynamic range (DR) and high linearity. By using a differential pulse code modulation (DPCM) technique, VCO non-linearity is mitigated by operating the VCO in the small-signal linear regime. To minimize power consumption from the power-hungry gain error calibration, the effect of VCO gain variation within the DPCM loop is investigated, leading to a calibration-free DPCM via a ΔΣ truncator. At the circuit level, a coarse-fine phase decoding scheme is proposed to increase signal-to-quantization-noise ratio (SQNR) while avoiding metastability issues. Fabricated in 65 nm, the AFE occupies an area of 0.056 mm². It achieves 94.2-dB SNDR and 95.1-dB DR in 500 Hz of bandwidth while dissipating 1.68-μW power from a single 0.8-V supply, yielding a Schreier FoM of 178.9 dB. Importantly, the techniques enable a virtually distortion-less spectrum with a noise-floor limited spurious-free dynamic range (SFDR) of 128 dB. In addition, the AFE is validated with ECG and EOG recording, demonstrating complete signal capturing in the presence of motion/stimulation artifacts.

8 October 2021 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
NFNader Sherif Kassem Fathy
Nader Sherif Kassem Fathy
JHJiannan Huang
Jiannan Huang
PMPatrick P. Mercier
Patrick P. Mercier
This article presents a low-power (LP) area-efficient implantable neural recording system that supports high-density neural implant (HDNI) applications. The system uses a time-division multiple access method to record from 16-neural electrodes simultaneously. A least mean squares (LMSs) algorithm is used to cancel the slowly varying electrode offsets from all channels simultaneously by using a single-tap digital adaptive filter (AF). The presented technique is fabricated in 65-nm CMOS technology and achieves a per-channel area of 0.00248 mm 2 ; 68% of which is digital circuitry (and is thus scalable with technology). The overall system consumes 3.38 $\mu \text{W}$ per channel while achieving 2.6 $\mu \text{V}_{\mathrm {rms}}$ of input referred noise (IRN) in 10 kHz of bandwidth. The proposed system has a noise efficiency factor (NEF) of 1.83 and is fully integrated on-chip.

13 February 2021
Verified
Conference Paper
Closed access
CPCorentin Pochet
Corentin Pochet
JHJiannan Huang
Jiannan Huang
PMPatrick P. Mercier
Patrick P. Mercier
DHDrew Hall
Drew Hall
Next-generation wearable devices will enable clinical-grade, continuous ExG (ECG, EEG, EMG, etc.) biopotential monitoring, providing medical professionals with valuable longitudinal data outside of hospital settings. These devices must be ultra-low power $(\lt 10 \mu W)$ to enable long battery life while accurately digitizing sub-kHz, $\mu V-$level ExG signals in the presence of large motion and/or stimulation artifacts $(\gt 100$ mV) with high input-impedance $(Z_{in}\gt 10M\Omega)$ to avoid signal attenuation. Achieving such performance with conventional PGA + ADC architectures is challenging due to the conflicting low-power and $\gt 90$ dB dynamic-range (DR) requirements [1]. To address this, several direct digitization analog front-ends (AFEs) have been reported [2]–[4]. While these offer wide DR, they typically have low input-impedance $(\lt 5 M\Omega)$ and/or low power-efficiency (FoM $\le 172$ dB). This paper presents a scalable $2^{nd}-$ order voltage-controlled oscillator (VCO)-only $\Delta \sum$ ADC that achieves 92.3dB SNDR in a 1kHz bandwidth using a mismatch tolerant, multiphase gated-inverted ring-oscillator (GIRO) quantizer with dynamic power-scaling. The ADC uses an impedance-booster to maintain $\gt 50 M\Omega$ input-impedance over the entire bandwidth while consuming $4.25 \mu W$ during nominal operation and $5.8 \mu W$ in the presence of artifacts resulting in an FoM of 174.7dB.