Kuilin Meng

Kuilin Meng

Auto-generated profile, based on publicly available information

Kuilin Meng

State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2020 in IEEE Access
Verified
Journal Article
Open access
YLYinbo Li
Yinbo Li
XGXinyu Guan
Xinyu Guan
XHXinyu Han
Xinyu Han
ZTZihan Tang
Zihan Tang
KMKuilin Meng
Kuilin Meng
LJLinhong Ji
Linhong Ji
Geared motor-driven lower limb exoskeletons (LLEs) are widely researched to assist paraplegic patients with spinal cord injury in recovering locomotion ability. In order to achieve a compact exoskeleton joint design while avoiding increasing the mechanical complexity of the exoskeleton frame, this study presents a design of an LLE with compact and modular actuation. A synchronous drive and a gear drive as transmissions are used to distribute hip and knee actuators, respectively, ensuring a compact axial length. The modular design of joint actuators enables it simple to separately design or select the ergonomic exoskeleton frames. A paradigm of the LLE design is comprehensively provided, including the requirement analysis, mechanical, electrical and control system design, which can be a reference of the early development of the exoskeleton prototype. The performance of the LLE is preliminarily validated by the benchtop tests including the closed-loop speed bandwidth test and the swing test and one healthy human subject experiment including walking with the LLE disenabling all motors and walking assisted by the LLE. The results of the benchtop tests validate that the LLE has enough bandwidth of closed-loop speed, satisfactory repeatability, high precision, good antijamming capability and strong torque capacity. The results of the healthy human subject experiment validate a harmonic interaction and a good integration between the user and the ergonomic mechanical system, good performance of the electrical and control system in joints motion control of the LLE. The prototype of the LLE smoothly and successfully assists the healthy human subject in walking on the level ground. The proposed LLE is promising to be applied to assist paraplegic patients in recovering the walking ability.

10 December 2023 in Advanced Materials Interfaces
Verified
Journal Article
Open access
KMKuilin Meng
Kuilin Meng
HCHaosheng Chen
Haosheng Chen
XZXiaobing Zheng
Xiaobing Zheng
YPYunfan Pan
Yunfan Pan
YLYongjian Li
Yongjian Li
Thrombosis is the main reason for the failure of ventricular assist devices (VADs). It has been acknowledged that the platelet activation induced by the nonphysiological blood flow leads to the increased thrombotic risk. However, due to the complicated influence of the VADs’ flow field and the difficulty in real‐time in situ observation, the mechanisms and process of thrombus formation in VADs remain unclear. In this work, the process of thrombus formation in VADs in vitro experiments is observed. The thrombus is found to form on the middle of the inlet guide vanes first and it is mainly caused by the immediate activation of platelets induced by the high shear rate of the flow field around the vanes and also affected by the rotation of the impeller. Then, subsequent thrombus is found in the tail of guide vanes and around the axle journal, where the blood flow is stagnated and the platelets are activated by the accumulated bioagonists. These findings clarify that the thrombus formed on the inlet guide vanes and the axle journal are dominated by two different mechanisms. This work provides unique insights into the initial formation of the thrombus on VADs and helps to reduce the thrombotic risk.

29 September 2025 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
KMKuilin Meng
Kuilin Meng
YWYumiao Wang
Yumiao Wang
JZJianye Zhou
Jianye Zhou
QLQiwei Liu
Qiwei Liu
HCHaosheng Chen
Haosheng Chen
YLYongjian Li
Yongjian Li
Background: High shear rate and non-physiological turbulent flow caused by bileaflet mechanical heart valves (BMHVs) lead to platelet activation and adhesion, which can cause rapid thrombus growth and severe consequences. Methods: This study employed computational modeling to analyze the effect of surface texture on flow field around the BMHVs. The textures’ positional, geometric, and dimensional parameters were optimized based on flow field analysis. The textured BMHVs were then implanted in sheep for 6 months, with pyrolytic carbon BMHVs serving as the control group. Results: The textured BMHVs significantly reduced high-velocity, low-velocity, high turbulent shear stress, and high shear rate regions in the flow field. Post-implantation, the experimental groups with textured BMHVs exhibited lower levels of platelet activation and neither the intrinsic nor extrinsic coagulation cascade reactions were activated in the sheep. Detailed observations revealed an absence of erythrocyte or platelet adhesion within the grooved texture regions, with minimal adhesion at the peripheral edges of the textured areas. Conclusion: The optimized surface textures on BMHVs effectively reduce adverse flow conditions and platelet activation, potentially decreasing the need for anticoagulant therapy and minimizing the associated bleeding risks. These findings are crucial for enhancing the long-term safety and efficacy of BMHV implantation.