Suhang Li

Suhang Li

Auto-generated profile, based on publicly available information

Suhang Li

Hangzhou Innovation Institute of Beihang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
ZJZhongxiang Jing
Zhongxiang Jing
FZFengwen Zhao
Fengwen Zhao
XYXiangyang Ye
Xiangyang Ye
SLSuhang Li
Suhang Li
GLGang Liu
Gang Liu
High-power devices used in hospitals generate harmonic magnetic field disturbances inside magnetic shielding cylinders (MSCs). These disturbances exhibit axial-gradient spatial distributions, which substantially degrade the imaging quality of magnetocardiography (MCG). To address this issue, a high-precision nonlinear spatial gradient disturbance suppression method is proposed for single-open MSCs. First, a nonlinear gradient coil design is developed to generate variable magnetic field gradients, precisely matching the nonlinear gradient distribution induced by external magnetic disturbances in the MSC. Subsequently, the entire system is modeled, and a composite controller based on proportional-integral repetitive control-linear extended state observer (PIRC-LESO) is designed to enhance the suppression of magnetic field disturbances with harmonic characteristics. Finally, an active magnetic field disturbance suppression system was implemented to evaluate the effectiveness of the nonlinear spatial gradient disturbance suppression method. Experimental results demonstrate that the proposed method reduces the peak-to-peak magnetic field disturbance from 42.0 to 6.9 pT and significantly enhances the signal-to-noise ratio of the MCG signals.

18 July 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYang Zhang
Yang Zhang
MWMeiting Wang
Meiting Wang
SLSuhang Li
Suhang Li
JIan ChenJIan Chen
JIan Chen
Jie LinJie Lin
Jie Lin
XSXinlei Shang
Xinlei Shang
Magnetic resonance sounding (MRS) is a noninvasive geophysical method that allows direct qualitative and quantitative detection of groundwater and it has been used widely to detect shallow groundwater. However, current MRS device structures suffer from tens of milliseconds of dead time due to the effect of coupling between the receiving and transmitting coils, which can lead to early data loss and signal distortion. This is especially true for small multiturn coil structures. To solve this problem, we propose an early free induction decay (FID) signal detection technique with a gradient coil for MRS, which consists of two equidistant receiving coils above and below the transmitting coil. This symmetric distribution eliminates the effect of coil coupling. Based on the proposed technique, a numerical model and a prototype of the principle were constructed. Simulation and experimental results show that the new method effectively suppresses the influence of transceiver coil coupling. The new method based on a gradient coil structure can acquire short relaxation FID signals and the dead time was reduced to 1 ms. The new method provides technical support for efficient and accurate detection of shallow groundwater.

28 May 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YCYimin Chen
Yimin Chen
SLSuhang Li
Suhang Li
BHBangcheng Han
Bangcheng Han
XHXiaoting Hong
Xiaoting Hong
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
RFRui Feng
Rui Feng
The complex electromagnetic disturbances often result in excessively high magnetic field noise. This article proposes a two-stage nested magnetic field control system based on time-frequency domain collaboration for a magnetically shielded room (MSR) to suppress the disturbance magnetic field and reduce magnetic field noise. The system creates a high-bandwidth external control system by placing external auxiliary coils and a fluxgate sensor outside the MSR, avoiding mutual interference with the internal control system. Subsequently, the system uses a self-tuning proportional-integral-derivative (PID) based on pole placement control and the gradient algorithm based on discrete Fourier transform to obtain the optimal internal noise level. This proposed method has effectively increased the control bandwidth while avoiding the design of complex two-stage decoupling strategies. Compared with the traditional only internal control system, the average noise suppression ability within the target frequency band has been improved by more than 20 $\mathbf{\%}$ .

21 April 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XWXuechun Wang
Xuechun Wang
Haitao LiHaitao Li
Haitao Li
SLSuhang Li
Suhang Li
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
YWYutong Wei
Yutong Wei
RYRunrun Yao
Runrun Yao
Magnetocardiography (MCG) is critical for early diagnosis and treatment of cardiac diseases. Arrayed SERF atomic magnetometers deliver high-quality MCG in a near-zero field provided by a magnetic shielding cylinder (MSC) with active magnetic compensation (AMC). However, the magnetic noise within the MSC is dynamic and gradient-distributed, making conventional single-stage uniform-field AMC inadequate. To overcome this, we propose a two-stage synergistic compensation method. It flattens the gradient along the MSC opening axis in the first stage and nulls the noise along the SERF sensitivity axis at the second stage. The feedback-sensor positions are optimized by an NSGA-II based multiobjective algorithm, enhancing the noise suppression at each stage while preserving cardiac signals and avoids complex decoupling calculations. Experiments show that both the noise amplitude and spatial gradient on the measurement panel are reduced. In the presence of external disturbance, the magnetic field gradient decreased from 117.84 to 2.78 pT/m. The average sensitivity decreased from 238.19 fT/Hz1/2@1–40 Hz to 22.18 fT/Hz1/2@1–40 Hz, significantly improving the MCG signal quality.