1 January 2021 in Journal of Applied Remote Sensing
<!-- *** Custom HTML *** --> Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.
1 April 2021 in Journal of Applied Remote Sensing
Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been in operation providing continuous global observations for science research and applications since 2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitored through inter-comparisons with measurements by hyperspectral or multi-spectral infrared sensors or through vicarious monitoring over cold targets such as Dome-C and deep convective clouds. The radiative transfer modeling (RTM)-based simulation models are developed to perform the long-term monitoring of the stability of Aqua MODIS TEBs. Long-term European Centre for Medium-Range Weather Forecasts global atmospheric reanalysis data are used as inputs to the RTM simulation. By confining ocean in low to middle latitudes as the area of interest, the long-term stabilities of Aqua MODIS TEBs are monitored through observation minus background (O-B) brightness temperature (BT) bias between MODIS measurements and simulations from the RTM. In general, the RTM-based O-B analysis shows that the long-term stability of Aqua MODIS TEBs are maintained well. It is shown that Aqua MODIS surface bands are all radiometrically stable with yearly BT bias drifts <0.005 K / year for B20, B22, and B23 and ∼0.01 K / year for B31 and B32. The carbon dioxide (CO2) absorption channels of Aqua MODIS, e.g., B33 to B36, are stable with a BT bias drift <0.005 K / year. It is also found that after accounting for the long-term growth of greenhouse gas N2O, the O-B bias trends for B24 and B25 are quite stable with yearly BT bias drifts around 0.0002 and 0.0055 K / year, respectively. The stabilities of the moisture-sensitive channels B27 to B29 and the ozone channel B30 of Aqua MODIS are also evaluated and the remnant small variations in the O-B bias trending of these channels are further discussed. The RTM-based inter-comparison of MODIS TEB measurements with global atmospheric and climate re-analysis data provides validation of the long-term radiometric stability of Aqua MODIS TEBs. The analysis in this paper also demonstrates that the comparison of well-calibrated MODIS TEB measurements with RTM simulation helps quantify the long-term impacts of global greenhouse gas concentration growth on the BT decreases in the MODIS greenhouse gas-sensitive channels.
1 April 2021 in Journal of Applied Remote Sensing
<!-- *** Custom HTML *** --> A technique that utilizes quasi-deep convective clouds (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has been proven viable. The Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) and Suomi-National Polar-orbiting Partnership (S-NPP) and NOAA-20 (N20) Visible Infrared Imaging Radiometer Suite (VIIRS) TEB calibration uses a nonlinear algorithm with nonlinear coefficients that rely on on-orbit blackbody (BB) warm-up and cool-down operations for updates. However, a limited BB temperature range affects the calibration’s accuracy, particularly for cold scenes. The deep convective clouds (DCC) core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments, more specifically, for the evaluation of the offset term’s effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide the advantage of removing solar reflectance effects during daytime, thus enhancing the assessment’s accuracy for the mid-wave infrared TEB. This qDCC method is applied to the Terra MODIS and VIIRS TEB, and their stabilities are assessed using long-term qDCC trending measurements over the instruments’ missions. The measurements from bands with an 11-μm wavelength are used to identify the DCC pixels. The 11-μm bands, MODIS band 31, and VIIRS bands M15 and I5 are stable throughout the MODIS and VIIRS missions and have shown excellent calibration accuracy and noise performance. Hence, using these bands as references, a normalization method is employed to enhance the accuracy of the stability and consistency assessments. The S-NPP VIIRS TEB show stable trends over the instrument’s mission. The S-NPP-to-N20 VIIRS comparison shows that their TEB measurements are consistent over qDCC. The Terra MODIS TEB also shows stable performance—except for bands 27, 29, and 30. Terra MODIS band 30 shows a large downward trend throughout the mission, whereas bands 27 and 29 show slight, upward drifts. Finally, a calibration correction using qDCC assessments is discussed and intended to be used in a future calibration algorithm collection.
1 January 2023 in Open-File Report
First posted July 20, 2023 Director, Earth Resources Observation and Science Center U.S. Geological Survey 47914 252nd Street Sioux Falls, SD 57198 Contact Pubs Warehouse The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 7–8 for quarter 1 (January–March) of 2023. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov. One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 safehold anomaly. On January 26, 2023, the Global Positioning System (GPS) onboard Landsat 8 became invalid because the GPS fault tripped. Later that same day, the GPS was reinitialized, but a Field of View 1 fault trip occurred early the next morning, causing the observatory to go into Earth Point Safe mode, which put the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) into safehold. Once it was safe to reactivate the sensors, the OLI was transitioned to operational status late on January 27 and TIRS was reactivated early on January 28. Additional information about the Landsat 8 safehold anomaly is here: https://www.usgs.gov/landsat-missions/news/landsat-8-recovers-safehold.