Chang Ye Gue

Chang Ye Gue

Auto-generated profile, based on publicly available information

Chang Ye Gue

Ph.D. Research Student, Centre for Smart Infrastructure and Construction, Dept. of Engineering, Univ. of Cambridge, Trumpington St., Cambridge CB2 1PZ, U.K.

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2015 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Open access
PDF file
CGC. Y. Gue
C. Y. Gue
MWM. Wilcock
M. Wilcock
MAM. M. Alhaddad
M. M. Alhaddad
MEM. Z. E. B. Elshafie
M. Z. E. B. Elshafie
KSK. Soga
K. Soga
RMR. J. Mair
R. J. Mair
Instrumentation is vital to tunnelling projects for validation of design assumptions, monitoring of trigger levels during construction and also serving as a feedback loop to understand the deformation mechanisms of the particular problem which could be used to improve future designs. It can also be used for long term monitoring of the tunnel for maintenance purposes. Distributed fibre optic sensing (DFOS) systems based on brillouin optical time domain reflectometry are able to provide continuous and distributed strain measurements to be taken along the entire length of, for example, an existing cast iron tunnel where the fibre optic cable length is fully attached. This enables engineers to understand the stresses and strains that develop within the lining caused by external influences; which in this case, the construction of a new tunnel directly underneath it, rather than relying on discrete point measurements of displacement from conventional methods of monitoring. Nonetheless, proper installation of DFOS is of paramount importance to obtain high quality data. This paper aims to provide some practical guidance on the planning and installation of DFOS and presents a brief case study on the monitoring of London’s Royal Mail tunnel during the construction of the large Crossrail platform tunnel, located directly below it at Liverpool Street Station. It demonstrates the potential benefits of using such systems in complex tunnelling scenarios.

1 March 2018 in Journal of Geotechnical and Geoenvironmental Engineering
Verified
Journal Article
Closed access
LPLoizos Pelecanos
Loizos Pelecanos
KSKenichi Soga
Kenichi Soga
MEMohammed Z. E. B. Elshafie
Mohammed Z. E. B. Elshafie
NBNicholas de Battista
Nicholas de Battista
CKCedric Kechavarzi
Cedric Kechavarzi
Hyungjoon SeoHyungjoon Seo
Hyungjoon Seo
Instrumented pile tests are vital to establish the performance of a pile and validate the assumptions made during initial design. Conventional instrumentation includes vibrating wire strain gauges and extensometers to measure the change in strain or displacements within a pile. Although these strain and displacement gauges are very accurate, they only provide strain/displacement readings at discrete locations at which they are installed. It is therefore common to interpolate between two consecutive points to obtain values corresponding to the data gaps between points; in practice, these discrete instrumented points could be tens of meters apart, at depths corresponding to different soil layers, and hence simple interpolation between the measurement points remains questionable. The Brillouin optical time-domain reflectometry fiber optic strain sensing system is able to provide distributed strain sensing along the entire length of the cable, enabling the full strain profile to be measured during a maintained pile load test. The strain data can also be integrated to obtain the displacement profile. This paper presents three case studies which investigate the performance of three concrete bored piles in London using both conventional vibrating wire strain gauges and distributed fiber optic strain sensing during maintained pile load tests, which enable comparisons made between the two instrumentation systems. In addition, finite-element analyses show that the ability to measure the full strain profiles for each pile is highly advantageous in understanding the performance of the pile and in detecting any abnormalities in the pile behavior.

30 March 2017
Verified
Conference Paper
Closed access
CGC. Y. Gue
C. Y. Gue
MWM. J. Wilcock
M. J. Wilcock
MAM. M. Alhaddad
M. M. Alhaddad
MEM. Z. E. B. Elshafie
M. Z. E. B. Elshafie
KSK. Soga
K. Soga
RMR. J. Mair
R. J. Mair
The response of existing tunnels to adjacent new tunnelling works is an area of special interest to both civil engineering designers and tunnelling engineers as well as asset owners. Field monitoring is critical as it provides vital data about the response of the existing tunnels that informs future design improvements. This paper focuses on the response of the existing, near century-old Royal Mail Tunnel in the vicinity of bond street London underground station in London, U.K. Cambridge’s ‘Centre for Smart Infrastructure and Construction’ (CSIC) deployed various state-of-the-art instrumentation systems to investigate the behaviour of the existing Royal Mail Tunnel during the construction of a new passenger tunnel as part of London underground bond street upgrade scheme. The instrumentation includes distributed fibre optic strain sensing (DFOS), photogrammetry and strain gauge instrumented tunnel bolts. The monitoring systems combined were able to provide a very good insight into the existing Royal Mail Tunnel behaviour, as the construction of the new tunnel beneath was undertaken.

1 January 2018
Verified
Book Chapter
Closed access
TATraian E. Abrudan
Traian E. Abrudan
ABAaron Bradshaw
Aaron Bradshaw
EBErika Bustos
Erika Bustos
LCLiang Cheng
Liang Cheng
NBNicholas De Battista
Nicholas De Battista
SYSuk-Un Yoon
Suk-Un Yoon