1 March 2018 in Journal of Geotechnical and Geoenvironmental Engineering
Instrumented pile tests are vital to establish the performance of a pile and validate the assumptions made during initial design. Conventional instrumentation includes vibrating wire strain gauges and extensometers to measure the change in strain or displacements within a pile. Although these strain and displacement gauges are very accurate, they only provide strain/displacement readings at discrete locations at which they are installed. It is therefore common to interpolate between two consecutive points to obtain values corresponding to the data gaps between points; in practice, these discrete instrumented points could be tens of meters apart, at depths corresponding to different soil layers, and hence simple interpolation between the measurement points remains questionable. The Brillouin optical time-domain reflectometry fiber optic strain sensing system is able to provide distributed strain sensing along the entire length of the cable, enabling the full strain profile to be measured during a maintained pile load test. The strain data can also be integrated to obtain the displacement profile. This paper presents three case studies which investigate the performance of three concrete bored piles in London using both conventional vibrating wire strain gauges and distributed fiber optic strain sensing during maintained pile load tests, which enable comparisons made between the two instrumentation systems. In addition, finite-element analyses show that the ability to measure the full strain profiles for each pile is highly advantageous in understanding the performance of the pile and in detecting any abnormalities in the pile behavior.
1 October 2015 in Journal of Composites for Construction
This paper investigates the structural behavior of uncorroded as well as corroded RC T-beams strengthened in shear with either externally bonded (EB) carbon fiber–reinforced polymer (CFRP) sheets or embedded CFRP rods. Nine tests were carried out on RC T-beams having an effective depth of 295 mm and a shear span to effective depth ratio of 3.05. The investigated parameters are the shear link corrosion level (uncorroded, 7% corroded, or 12% corroded) and type of CFRP strengthening system (EB CFRP sheets or embedded CFRP rods). The unstrengthened beams with shear link corrosion levels of 7 and 12% had shear strengths that were 11 and 14%, respectively, less than the shear strength of the uncorroded unstrengthened beam. Both the embedded CFRP rods and EB CFRP sheets were effective in enhancing the shear strength of tested beams but the effectiveness of both strengthening systems decreased with increasing shear link corrosion level. The shear strength enhancement provided by the embedded CFRP rods and EB CFRP sheets decreased from 19 and 15%, respectively, to 12 and 11%, respectively, with an increase in shear link corrosion level from 7 to 12%. Corrosion of the shear links did not have a significant effect on the beam stiffness. Premature debonding limited the effectiveness of the EB CFRP sheets whereas the embedded CFRP rods did not exhibit signs of debonding and therefore showed higher effectiveness.