Mohammed Z. E. B. Elshafie

Mohammed Z. E. B. Elshafie

Auto-generated profile, based on publicly available information

Mohammed Z. E. B. Elshafie

Univ. of Cambridge

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Journal of Geotechnical and Geoenvironmental Engineering
Verified
Journal Article
Closed access
LPLoizos Pelecanos
Loizos Pelecanos
KSKenichi Soga
Kenichi Soga
MEMohammed Z. E. B. Elshafie
Mohammed Z. E. B. Elshafie
NBNicholas de Battista
Nicholas de Battista
CKCedric Kechavarzi
Cedric Kechavarzi
Hyungjoon SeoHyungjoon Seo
Hyungjoon Seo
Instrumented pile tests are vital to establish the performance of a pile and validate the assumptions made during initial design. Conventional instrumentation includes vibrating wire strain gauges and extensometers to measure the change in strain or displacements within a pile. Although these strain and displacement gauges are very accurate, they only provide strain/displacement readings at discrete locations at which they are installed. It is therefore common to interpolate between two consecutive points to obtain values corresponding to the data gaps between points; in practice, these discrete instrumented points could be tens of meters apart, at depths corresponding to different soil layers, and hence simple interpolation between the measurement points remains questionable. The Brillouin optical time-domain reflectometry fiber optic strain sensing system is able to provide distributed strain sensing along the entire length of the cable, enabling the full strain profile to be measured during a maintained pile load test. The strain data can also be integrated to obtain the displacement profile. This paper presents three case studies which investigate the performance of three concrete bored piles in London using both conventional vibrating wire strain gauges and distributed fiber optic strain sensing during maintained pile load tests, which enable comparisons made between the two instrumentation systems. In addition, finite-element analyses show that the ability to measure the full strain profiles for each pile is highly advantageous in understanding the performance of the pile and in detecting any abnormalities in the pile behavior.

1 October 2015 in Journal of Composites for Construction
Verified
Journal Article
Closed access
SQShunde Qin
Shunde Qin
SDSamir Dirar
Samir Dirar
JYJian Yang
Jian Yang
ACAndrew Hin Cheong Chan
Andrew Hin Cheong Chan
MEMohammed Elshafie
Mohammed Elshafie
This paper investigates the structural behavior of uncorroded as well as corroded RC T-beams strengthened in shear with either externally bonded (EB) carbon fiber–reinforced polymer (CFRP) sheets or embedded CFRP rods. Nine tests were carried out on RC T-beams having an effective depth of 295 mm and a shear span to effective depth ratio of 3.05. The investigated parameters are the shear link corrosion level (uncorroded, 7% corroded, or 12% corroded) and type of CFRP strengthening system (EB CFRP sheets or embedded CFRP rods). The unstrengthened beams with shear link corrosion levels of 7 and 12% had shear strengths that were 11 and 14%, respectively, less than the shear strength of the uncorroded unstrengthened beam. Both the embedded CFRP rods and EB CFRP sheets were effective in enhancing the shear strength of tested beams but the effectiveness of both strengthening systems decreased with increasing shear link corrosion level. The shear strength enhancement provided by the embedded CFRP rods and EB CFRP sheets decreased from 19 and 15%, respectively, to 12 and 11%, respectively, with an increase in shear link corrosion level from 7 to 12%. Corrosion of the shear links did not have a significant effect on the beam stiffness. Premature debonding limited the effectiveness of the EB CFRP sheets whereas the embedded CFRP rods did not exhibit signs of debonding and therefore showed higher effectiveness.

30 March 2017
Verified
Conference Paper
Closed access
CGC. Y. Gue
C. Y. Gue
MWM. J. Wilcock
M. J. Wilcock
MAM. M. Alhaddad
M. M. Alhaddad
MEM. Z. E. B. Elshafie
M. Z. E. B. Elshafie
KSK. Soga
K. Soga
RMR. J. Mair
R. J. Mair
The response of existing tunnels to adjacent new tunnelling works is an area of special interest to both civil engineering designers and tunnelling engineers as well as asset owners. Field monitoring is critical as it provides vital data about the response of the existing tunnels that informs future design improvements. This paper focuses on the response of the existing, near century-old Royal Mail Tunnel in the vicinity of bond street London underground station in London, U.K. Cambridge’s ‘Centre for Smart Infrastructure and Construction’ (CSIC) deployed various state-of-the-art instrumentation systems to investigate the behaviour of the existing Royal Mail Tunnel during the construction of a new passenger tunnel as part of London underground bond street upgrade scheme. The instrumentation includes distributed fibre optic strain sensing (DFOS), photogrammetry and strain gauge instrumented tunnel bolts. The monitoring systems combined were able to provide a very good insight into the existing Royal Mail Tunnel behaviour, as the construction of the new tunnel beneath was undertaken.

23 November 2017
Verified
Book Chapter
Closed access
PDF file
NFN.E. Faustin
N.E. Faustin
RMR.J. Mair
R.J. Mair
MEM.Z.E.B. Elshafie
M.Z.E.B. Elshafie
CMC.O. Menkiti
C.O. Menkiti
MBM. Black
M. Black

30 March 2017
Verified
Conference Paper
Closed access
TSTalia S. da Silva
Talia S. da Silva
MEMohammed Z. E. B. Elshafie
Mohammed Z. E. B. Elshafie
GMGopal Santana Phani Madabhushi
Gopal Santana Phani Madabhushi
The average vertical pressure on a buried structure can be calculated using the silo theory, which assumes the translation of a vertical prism of soil above the structure that is resisted by friction on the sides of the prism. One of the key assumptions made is the value of the coefficient of lateral stress, K. In this study, an assumption regarding the rotation of principal stresses in the yielding soil has been used to calculate the average coefficient of lateral stress acting at the side of a prism of yielding soil above the horizontal buried structure. The calculated value using the proposed method agrees well with experimental observation made in literature for the value of K, and is suggested for use in the estimation of loads on buried structures, where it is expected that the structure will yield relative to a stiff body of soil.