1 April 1997 in Journal of Low Temperature Physics
1 June 1995 in Journal of Low Temperature Physics
21 September 2020 in Applied Physics Letters
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.
15 November 1997 in Acta Crystallographica Section C Crystal Structure Communications
9 December 2016 in IEEE Transactions on Applied Superconductivity
In order to read out current signals from large-scale arrays of transition edge sensors (TES), microwave SQUID multiplexers (MW-MUX) have been developed by several groups. Reduction of crosstalk induced in the multiplexer is important in order to maintain the energy resolution or the noise equivalent power of detector arrays. In the present study, crosstalk between channels in MW-MUX with five different designs is experimentally evaluated. The resonance frequency separation is ten times as large as the resonator bandwidth. Without flux-ramp modulation, crosstalk between two adjacent channels neighboring in position decreases to ≈1 × 10 -3 with increasing resonance frequency separation to ≈100 MHz. Crosstalk between SQUID channels neighboring in resonance frequency also decreases to 4 × 10 -3 with increasing the distance to 2.5 mm. We show that nonlinear error can occur due to the crosstalk with flux-ramp modulation. Flux readings from a well-designed multiplexer exhibit crosstalk of less than 1 mΦ 0 peak-to-peak and nonlinear errors of less than 2 mΦ 0 peak-to-peak, which is sufficient for the readout of the gamma-ray TES arrays being developed. These results can provide guidelines for suppressing both the crosstalk and the nonlinear error to less than the criterion of TES spectrometers with typical energy-resolving ability.
18 March 2019 in IEEE Transactions on Applied Superconductivity
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics were evaluated, and the results showed that the distortion of the SQUID characteristics and the degradation of its noise performance were not clearly observed. Finally, we have developed a MW-Mux microstrip SQUID with a low current noise of $\rm \lt 20 pA/\sqrt{Hz}$ which is below the typical noise of our TES X-ray microcalorimeter, $\rm 30 pA/\sqrt{Hz}$ .