Huib Ruitenbeek

Huib Ruitenbeek

Auto-generated profile, based on publicly available information

Huib Ruitenbeek

Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center, PO Box 2040, 3015 GD, Rotterdam, the Netherlands

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2024 in Radiology
Verified
Journal Article
Closed access
MBMathias W. Brejnebøl
Mathias W. Brejnebøl
ALAnders Lenskjold
Anders Lenskjold
KZKatharina Ziegeler
Katharina Ziegeler
HRHuib Ruitenbeek
Huib Ruitenbeek
FMFelix C. Müller
Felix C. Müller
MBMikael Boesen
Mikael Boesen
In this retrospective, three-center, multireader study using consecutive knee radiographs in patients with suspected osteoarthritis, concurrent artificial intelligence assistance improved osteoarthritis grading performance of junior readers and increased interobserver agreement across all readers.

20 June 2024 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
HRHuibert C. Ruitenbeek
Huibert C. Ruitenbeek
EOEdwin H. G. Oei
Edwin H. G. Oei
JVJacob J. Visser
Jacob J. Visser
RKRichard Kijowski
Richard Kijowski

16 August 2023 in medRxiv
Verified
Preprint
Open access
PDF file
HRHuib Ruitenbeek
Huib Ruitenbeek
LELiv Egnell
Liv Egnell
KZKatharina Ziegeler
Katharina Ziegeler
MBMathias Willadsen Brejnebøl
Mathias Willadsen Brejnebøl
JNJanus Uhd Nybing
Janus Uhd Nybing
JVJacob Visser
Jacob Visser
Background Rapidly diagnosing fractures in appendicular skeletons is vital in the ED, where junior physicians often interpret initial radiographs. However, missed fractures remain a concern, prompting AI-assisted detection exploration. Yet, existing studies lack clinical context. We propose a multi-center retrospective study evaluating the AI aid RBfracture™ v.1, aiming to assess AI’s impact on diagnostic thinking by analyzing consecutive cases with clinical data, providing insights into fracture detection and clinical decision-making. Objectives To provide new insights on the potential value of AI tools across borders and different healthcare systems. We will evaluate the performance of the AI aid to detect fractures on conventional x-ray images and how its use could affect handling of these cases in a healthcare setting. In order to explore if the use of a trained and certified AI tool on clinical data exposes new challenges, a daily practice clinical scenario will be approached by minimising selection criteria and using consecutive cases. A multicenter, retrospective, diagnostic accuracy cross-sectional design incorporates clinical context. Methods The multicenter study spans three European sites without onsite hardware. AI system RBfracture™ v.1 maintains consistent sensitivity and specificity thresholds. Eligibility involves age ≥21 with x-ray indications for appendicular fractures. Exclusions include casts, follow-up x-rays, nearby hardware. AI aids retrospective fracture detection. Reader sessions include radiology and emergency care residents and trainees reading with and without AI. Fractures are marked, rated, with expert-established reference standards. Data Sequential patient studies at three sites yield 500 cases per site. Data includes anatomy, referral notes, radiology reports, and radiographic images. Expert readers use annotations, clinical context for standards. Statistical methods include dichotomized confidence ratings, sensitivity, specificity calculations, site-based analysis and subgroup considerations. Reference Standard Two experienced readers annotate fractures; if their annotations overlap by 25% or more, the common area is the reference. Discrepancies are resolved by a local expert. Individual fractures are labelled.

1 August 2026 in Radiology
Verified
Journal Article
Closed access
HRHuibert C. Ruitenbeek
Huibert C. Ruitenbeek
MBMathias Willadsen Brejnebøl
Mathias Willadsen Brejnebøl
GGGozde gunes
Gozde gunes
BZBas J. van der Zwart
Bas J. van der Zwart
MBMarna G. Bouwhuis
Marna G. Bouwhuis
JVJacob Visser
Jacob Visser
In this multinational and multireader study, a radiography-based artificial intelligence tool for fracture detection showed robust performance and conferred the greatest benefits to less experienced readers.

14 March 2024 in medRxiv
Verified
Preprint
Open access
PDF file
MBMathias Willadsen Brejneboel
Mathias Willadsen Brejneboel
MBMikael Boesen
Mikael Boesen
Kay Geert HermannKay Geert Hermann
Kay Geert Hermann
EOEdwin Oei
Edwin Oei
HRHuib Ruitenbeek
Huib Ruitenbeek
JNJanus Uhd Nybing
Janus Uhd Nybing
Background and rationale Knee osteoarthritis (OA) is a common disease characterized by reduced function, stiffness, and pain. This clinical diagnosis is commonly supported with radiography of the weight-bearing knee. Radiographic features, such as the Kellgren-Lawrence (KL) grading system, are used as eligibility criteria for clinical studies while others, such as the OARSI grades and minimal joint space width, are used as endpoints for structural OA progression. A higher preoperative KL-grade has been correlated with better pain- and functional outcomes after knee arthroplasty surgery. Consequently, the KL-grade is a common requirement for approving knee arthroplasty among American health insurance providers and it is commonly used by orthopedic surgeons as part of determining knee arthroplasty candidacy. Historically, a radiologist was required to draw on and grade radiographs of the knee to extract the features. With increasing computational power and the increased use of deep convolutional neural networks, off-the-shelf artificial intelligence (AI) tools have become available for automatic extraction of these features. They have received regulatory approval for commercialization but it is apparent that more diligent external validation is required. Finally, as AI tools begin to mature, new versions are released. It is important to assess how these developments change the current performance of the tool. Objectives The aim of this analysis is to evaluate the performance of a commercially available AI tool for grading tibiofemoral OARSI grades, KL grades and patellar osteophytes as well as the accuracy of measuring joint space width. Additionally, a change impact analysis will be performed where the performance of the current version of the AI tool will be compared to that of the previous version. Methods This study is a secondary analysis of the data from the AutoRayValid-RBknee study, a retrospective observer performance study. It consists of non-fixed-flexion radiographs acquired from the production picture archiving and communications system (PACS) from three European centers. Root mean square error (RMSE) will be used for estimating the accuracy of minimal and fixed-location joint space width (JSW) measurements. Ordinal ROC will be used for estimating ordinal OARSI-grade and the KL-grade classification AUC. Area under the receiver operating curve (AUC) is used for estimating binary OARSI-grade and patellar osteophyte classification performance. Population Patients with knee pain referred for radiography on suspicion of knee osteoarthritis Index test RBknee-2.2.0 (CE version, KL-grading, OARSI grading, patellar osteophytes) and RBknee-fda-1.0.1 (FDA version, Joint Space Width measurement). RBknee-2.1.0 (CE version, KL-grading, OARSI grading, patellar osteophytes) will be used to perform the change impact analysis of advancing product development. Reference test For all discrete variables, the reference value will be the majority vote, arbitrated by consensus where grades differ by 2 or more. The readers will be three board-certified musculoskeletal radiologists with substantial clinical and research experience. For continuous variables, annotation will be done by a single radiologist trained in the task. The annotations will be reviewed by a board-certified musculoskeletal radiologist with substantial clinical and research experience. Sample size Not applicable as this is a secondary analysis. Framework This is a diagnostic test accuracy study assessing the performance of a commercially available AI tool for radiographic evaluation of knee osteoarthritis according to established grading systems. Additionally, change impact analysis will be performed where multiple versions of the AI tool are available. Confidence intervals and P values All 95% confidence intervals and P values will use an alpha of 5%. Multiplicity No explicit multiplicity correction will be performed. Instead a hierarchical approach will be taken based on tabular order of the tested hypotheses. Statistical software R version 4.2.2 (or newer).