8 June 2022 in IEEE Transactions on Automation Science and Engineering
The electrical packaging for high power devices such as IGBT or MOSFET is achieved by heavy aluminum ultrasonic wire bonding. In this process, the amplitude stability of ultrasonic transducer determines the bonding quality, which demands more accuracy in resonant frequency tracking (RFT) and constant amplitude control (CAC). In this investigation, we proposed a vector based resonant frequency (VRFT) tracking and vector based constant amplitude control (VCAC) to control the ultrasonic transducer. The current of dynamic branch was conducted by calculating the voltage and current vector of ultrasonic transducer. Small signal model of ultrasonic transducer was established and applied into RFT and CAC. A control strategy of fuzzy self-tuning PID closed loop was utilized to RFT and CAC. The PID parameters was calculated by the linear control theories and modified by the fuzzy controller which improved the vibration stability of the transducer. A prototype of 100Watt/60kHz ultrasonic driver was self-developed to verify the VRFT and VCAC. It demonstrated that the locked frequency of VRFT can be controlled within less than 0.04 millisecond when staring from the swept frequency, and the vibration response is fast with the varying bonding pressure. The amplitude of fuzzy PID VCAC is more stable and robust compared to the classical PID control, which improved the bonded joint quality in heavy aluminum wire packaging. Note to Practitioners—This article was motivated by the reliability and efficiency of IGBT/ MOSFET device packaging through ultrasonic aluminum wire bonding. This bonding process requires more amplitude stability of the ultrasonic transducer to achieve acceptable bonded quality. Currently, the resonant frequency tracking (RFT) by classical PID control is in slow speed, and the amplitude of the transducer cannot be controlled constantly due to the inherent static capacitor of the transducer. These issues for the ultrasonic control are originated from the engineer’s experience or simple heuristic rule instead of advanced approaches. To improve the vibration performance, we proposed a vector based model consisting of the relationship the dynamic branch current and the total current of the transducer, to control the RFT and constant amplitude control (CAC). Moreover, the vector based is utilized into the fuzzy PID control, where the calculation is reduced by area coefficient defuzzy. The verification experiments prove that the response time of the proposed vector based RFT and CAC, and the bonded joint quality is optimized obviously. It is noted that in our control strategy, the RMS value, the phase of voltage and current of the transducer are acquired by DSP processor, and the calculation of fuzzy PID controller is not complicated, which is feasible to implement in application. This significantly benefits the demand of accurate control to the ultrasonic power in electronic packaging.
20 October 2020 in IEEE Transactions on Automation Science and Engineering
Rotary ultrasonic machining (RUM) is a superior technology to machine hard and brittle materials. Traditionally, the compensation optimization for the RUM system is limited to a single resonant frequency. This article presents a novel double compensation approach for the impedance and frequency regulations of RUM via multiobjective genetic algorithm (MOGA) aiming to achieve the system resonance and monitor the machining process in real time. For this, we first establish the impedance model of the rotary ultrasonic holder (RUH) by adopting the T-type circuit that includes the comprehensive electromagnetic parameters. The obtained impedance model reveals that both frequency mismatch and impedance mismatch exist in the RUM system, causing the low voltage gain and low vibration transmission. To obtain the optimal compensation to match both the frequency and impedance, an optimization model-based MOGA is developed to intelligently search the accurate capacitance values, where the Pareto frontier is employed to visualize the capacitance solution distribution. Moreover, the response feature of the RUH system is attained by using the state-space equation. Detailed comparisons of four compensation topologies show that the series-series (SS) topology offers the optimal performance, which can match both of the frequency and the impedance well, improving the output active power 7.634 times compared to the conventional one. Finally, the validity of the proposed optimization method is confirmed by using both simulations and experiments.
2 June 2020 in Journal of Manufacturing Science and Engineering
Rotary ultrasonic machining (RUM) is an effective solution to cut, grind, or drill the advanced brittle hard materials. Contactless rotary transformer, with the advantages of high-power transmission efficiency and reliability, is a potential structure to transmit electric power in RUM. In this study, an impedance model of rotary ultrasonic holder (RUH) is established to find that there exist deviations for the resonant frequency and impedance between the RUH and the ultrasonic transducer, indicating that without compensation the ultrasonic transducer cannot find precisely its own resonant frequency by sweeping frequency. To match the resonant frequency and impedance, four compensation topologies are compared and the Series-Series (SS) topology is discovered as the most suitable option. The compensated capacitance values are determined by visualized solution from the contour line method. Both simulation (from matlab–simulink) and experimental results validate that with compensation elements, the resonant frequency and impedance can be matched precisely between the RUH and ultrasonic transducer and the output voltage and current are with better dynamic performance. Moreover, with the same input voltage, the received power of ultrasonic transducer with compensation capacitors is 7.4 times than the one without compensation. Results verify that the compensation optimization of contactless rotary transformer can improve the vibration amplitude in RUM.
25 July 2022 in IEEE Sensors Journal
With the advantages of non-contact, compatibility, no chemical effect and safety, acoustic levitation of object has great potential to apply in chemistry, biology, medicine field and micro robots. Suspension to large particle higher than the half wavelength( $0.5\lambda $ ) of sound wave, is a challenge technology in micro-nanoscale manipulation. An increased large quantity probes, double sided and four sided phased array with virtual vortex can provide higher capture power, control ability and stability of particle fixation and the manipulation. However, for a limited confined space, the additional probes and sided phased array emission and receiving device is hard to be established and applied. Additional probes and sided ultrasonic phased array requires higher processing ability of MCU (Micro Control Unit) and the quantities of transducers. Further, multiparticles suspension is rare to be reported. In this study, a relatively simple suspension device of one sided concave spherical transducer array is designed, aiming to levitate a large particle and multi-particles. Based on the one sided acoustic field simulation of ultrasonic array, the optimized structure of open spherical sector (OSS) is constructed to establish levitation device. Experimental platform integrating FPGA controller, amplifier and impedance matching is developed to drive the transducer arrays, where a polystyrene particle with 6 mm ( $0.71\lambda $ ) diameter is successfully levitated. The virtual twin trap sound pressure of transducer array is measured to evaluate the particle stability. Experiments demonstrate the correctness of virtual twin trap acoustic field analysis, the feasibility in the manipulation to the large particle and multi-particles by acoustic trap.
9 February 2021 in IEEE Access
Rotary ultrasonic machining (RUM) has been proven to be a suitable technology for micro-nano precision manufacturing for hard and brittle ceramics/composite materials. However, the working frequency of the ultrasonic transducer in current RUM is in range from 20 kHz to 30 kHz. Moreover, the tool is tightened by an elastic chuck, which is in low clamping precision, high radial run-out, and unstable ultrasonic energy transmission. In this paper, we developed a novel heat shrinkable RUM ultrasonic transducer with 60 kHz frequency by equivalent circuit and finite element method (FEM). An analytical electromechanical equivalent circuit model was deduced to obtain the initial structure dimensions of the ultrasonic transducer. Three flange mounting structures were proposed to optimize and improve the energy transmission at the working resonant frequency. The influence of the proposed flanges on the resonant frequency of three transducers was analyzed and presented. The designed transducers were manufactured and tested in experiment. It shows that resonant frequencies of these three transducers with step, circular, and plate flange are 62.2 kHz, 61.46 kHz, and 61.4 kHz, and vibration amplitudes in 90 V driving voltage are 1.33μm, 4.74μm, 5.33μm, respectively. The working resonant frequencies by experimental measurement are consistent with the calculation result of the equivalent circuit and FEM. Moreover, the plate flange transducer shows the optimal amplitude capability with enough ultrasonic energy in micro-nano precision manufacturing.
5 June 2023 in IEEE Sensors Journal
With unique advantages of reducing noise pollution, lengthening the propagation distance, directional sound system (DSS) is a novel technology to control sound directivity based on modulation algorithm. By using the double side band amplitude modulation (DSB-AM), we successfully design a DSS device and the experimental verification is conducted to evaluate the performance of the sound directivity with different ultrasonic array. The modulation and self-demodulation based on DSB-AM is simulated, which proves theoretically that the audible sound can be transmitted with ultrasound signal and recovered in air. The sound directivity influenced by operating frequency is simulated to determine carrier frequency. To attain optimal arrangement of the ultrasound array, the square and rectangular array is constructed in the simulation. We develop a DSS hardware configuration to investigate sound directivity of ultrasonic array. It proves that the envelope of the modulated signal is matched with the original audio signal when modulation factor m=0.5 is chosen, which can ensure the performance of transmitting sound. The sound directivity of ultrasonic array is evaluated qualitatively and quantitatively. The experiments show that the 7×7 array has the better sound directivity than the rest of arrays, where the minimum emitting angle of main beam is produced. Sound directivity demonstration solidly verifies the superiority of 7×7 array in audible music propagation.