Similar to the conventional three-phase parallel-connected MMC (PC-MMC), the three-phase series-connected MMC (SC-MMC) is a strong potential solution for high-voltage direct current (HVDC) applications. The study of SC-MMC focuses on the control strategy, neglecting its small-signal dynamics, not to mention its stability when interacting with the AC grid. Work on small-signal modeling of MMC is limited to parallel-connected configurations. SC-MMC differs from PC-MMC in structure and harmonic content; hence, it is necessary to establish an accurate model of SC-MMC according to its own characteristics. This paper introduces the circuit and control of SC-MMC and compares it with PC-MMC. Multi-harmonic linearization is used to establish the AC impedance model of SC-MMC over the whole control system, including the third harmonic suppression controller. We take a PC-MMC station of the Wudongde HVDC project as a benchmark to explore the potential application of SC-MMC when constructing new HVDC stations to extract power from an existing DC transmission corridor. The strengths and weaknesses of SC-MMC in HVDC applications are discussed, and it is compared to PC-MMC with regard to the impedance characteristic.
1 February 2014 in IET Generation, Transmission & Distribution
Modular multilevel converter (MMC) is troubled by the inherent second harmonic of single‐phase ac power. By adding feedforward to the modulation signal, low‐frequency harmonic voltages are significantly reduced thus overcoming an important weakness of MMC. Capacitors of sub‐modules do not have to be over‐sized. If desired for protection, transformers can be wye‐connected with grounded neutral. The reduction method is based on harmonic function analysis. In addition to deriving algebraic formulae of harmonic voltage components of ‘open loop’ control, this study makes original contributions by deriving formulae which include feedforward control. Analytical insights from the formulae have shown the way to design feedforward methods to reduce low‐frequency harmonics. Validation is by simulations using SIMULINK/MATLAB.
6 February 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Active commutated or naturally clamped techniques have emerged as a new solution to achieve wide range soft-switching and eliminate the necessity of active clamping circuit of current-fed bidirectional DC/DC converter. Multiple typical modulation schemes have been proposed, which include single phase shift (SPS) modulation, dual phase shift (DPS) modulation, and discontinuous current single phase shift (DCSPS) modulation. DCSPS provides the lowest circulating current compared with prior two modulations, but it suffers from the problem of resonance and high peak current at partial loads. This paper proposes a discontinuous current dual phase shift (DCDPS) modulation based on the existing modulations. The duty cycles of the two legs on the high voltage side are controlled to be unsymmetrical to solve the current resonance problem in DCSPS. Extra phase shift is introduced to achieve much lower circulating current at wide range load conditions. Zero current switching (ZCS) of primary switches and zero voltage switching (ZVS) of secondary switches can be achieved over wide input range and wide load range. A 250-W laboratory converter prototype has been built. Experimental results are presented to validate the analysis and design.
2 June 2020 in Journal of Manufacturing Science and Engineering
Rotary ultrasonic machining (RUM) is an effective solution to cut, grind, or drill the advanced brittle hard materials. Contactless rotary transformer, with the advantages of high-power transmission efficiency and reliability, is a potential structure to transmit electric power in RUM. In this study, an impedance model of rotary ultrasonic holder (RUH) is established to find that there exist deviations for the resonant frequency and impedance between the RUH and the ultrasonic transducer, indicating that without compensation the ultrasonic transducer cannot find precisely its own resonant frequency by sweeping frequency. To match the resonant frequency and impedance, four compensation topologies are compared and the Series-Series (SS) topology is discovered as the most suitable option. The compensated capacitance values are determined by visualized solution from the contour line method. Both simulation (from matlab–simulink) and experimental results validate that with compensation elements, the resonant frequency and impedance can be matched precisely between the RUH and ultrasonic transducer and the output voltage and current are with better dynamic performance. Moreover, with the same input voltage, the received power of ultrasonic transducer with compensation capacitors is 7.4 times than the one without compensation. Results verify that the compensation optimization of contactless rotary transformer can improve the vibration amplitude in RUM.
Due to the voltage drop of the line impedance, power-transfer deviation occurs in the interlinking converter (IC) of hybrid microgrids. In this paper, an IC control strategy in hybrid microgrids is proposed, which can estimate the line resistance precisely. Moreover, the proposed method can easily realize accurate power transmission between sub-grids and maintain the power balance of hybrid microgrid. Firstly, one specified small signal is injected into the IC at the AC bus of the distributed generation so as to estimate the line impedance. The frequency of the injected small signal is highly relevant to the AC bus voltage. As a result, the IC can accurately detect its line impedance by extracting the injected small signal frequency with a filter and phase-lock-loop (PLL) without communication. Secondly, with the line impedance estimation, the voltage drop on the line can be compensated with local information of the IC, and consequently, accurate power transfer can be realized. Finally, the validity of the proposed method is verified by simulation and experiment results.