Chengwei Liu

Chengwei Liu

Auto-generated profile, based on publicly available information

Chengwei Liu

State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
XCXuying Chen
Xuying Chen
CLChengwei Liu
Chengwei Liu
DYDengfei Yang
Dengfei Yang
XLXinxin Liu
Xinxin Liu
Liang HuLiang Hu
Liang Hu
Jin XieJin Xie
Jin Xie
This paper describes a highly accurate airflow volumetric flowmeter using piezoelectric micromachined ultrasonic transducers (pMUTs) arrays based on transit time. Two pieces of 10by10 multipled aluminum nitride (AlN) pMUTs arrays at resonant frequency of 980 kHz are employed to transmit and receive ultrasonic signals alternately. The dimension of the fabricated 10by10 array is about 3.5 × 3.5 mm 2 , so the pMUTs-based flowmeter is able to measure flow rate in a 3D-printed pipe with an inner diameter of 10 mm. An evaluation board TDC1000-TDC7200EVM with resolution in ns is used to excite the transducers and handle the received signal. Leveraging on the high signal to noise ratio (SNR, ~29 dB) of the pMUTs array and excellent resolution (ns) of the evaluation board, the flowmeter has high accuracy. For the reference volumetric flow rate varying from 0-9 L/min in the range of laminar flow, the relative errors of the correctional volumetric flow are within 3%.

1 January 2019
Verified
Conference Paper
Closed access
XCXuying Chen
Xuying Chen
CLChengwei Liu
Chengwei Liu
JXJinghui Xu
Jinghui Xu
HCHong Chen
Hong Chen
YWYong Wang
Yong Wang
JXJin Xie
Jin Xie
This paper describes a high-accuracy airflow volumetric flowmeter using piezoelectric micromachined ultrasound transducers (pMUTs) arrays based on the transit-time. Two pieces of 10by10 multipled aluminum nitride (AlN) pMUTs arrays at resonant frequency of 980 kHz are employed to transmit and receive ultrasonic signals alternately. The dimension of the fabricated 10by10 array is about $3.5\times 3.5\ \text{mm}^{2}$ , so the pMUTs-based flowmeter can conveniently measure the flow rate in small pipes. Leveraging on the high signal to noise ratio (SNR, ∼29 dB) of the pMUTs and good resolution (ns) of the evaluation board, the flowmeter has high accuracy. The relative errors of the correctional volumetric flow are within 3% for the reference flow rate in the range from 0–9 L/min in a pipe with a diameter of 10 mm.

2 June 2024 in Computers & Fluids
Verified
Journal Article
Closed access
ASAkram Samy
Akram Samy
SLShu Li
Shu Li
XYXingfei Yuan
Xingfei Yuan
CLChengwei Liu
Chengwei Liu
YDYongcan Dong
Yongcan Dong