Ilona Anderson

Ilona Anderson

Auto-generated profile, based on publicly available information

Ilona Anderson

Clinical Research Department, MED-EL GmbH, Austria

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2009 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SBStefan Brill
Stefan Brill
JMJoachim Müller
Joachim Müller
RHRudolf Hagen
Rudolf Hagen
AMAlexander Möltner
Alexander Möltner
SBSteffi-Johanna Brockmeier
Steffi-Johanna Brockmeier
SSStefan Strahl
Stefan Strahl
Background: The standard electrode array for the MED-EL MAESTRO cochlear implant system is 31 mm in length which allows an insertion angle of approximately 720°. When fully inserted, this long electrode array is capable of stimulating the most apical region of the cochlea. No investigation has explored Electrically Evoked Compound Action Potential (ECAP) recordings in this region with a large number of subjects using a commercially available cochlear implant system. The aim of this study is to determine if certain properties of ECAP recordings vary, depending on the stimulation site in the cochlea. Methods: Recordings of auditory nerve responses were conducted in 67 subjects to demonstrate the feasibility of ECAP recordings using the Auditory Nerve Response Telemetry (ART™) feature of the MED-EL MAESTRO system software. These recordings were then analyzed based on the site of cochlear stimulation defined as basal, middle and apical to determine if the amplitude, threshold and slope of the amplitude growth function and the refractory time differs depending on the region of stimulation. Results: Findings show significant differences in the ECAP recordings depending on the stimulation site. Comparing the apical with the basal region, on average higher amplitudes, lower thresholds and steeper slopes of the amplitude growth function have been observed. The refractory time shows an overall dependence on cochlear region; however post-hoc tests showed no significant effect between individual regions. Conclusions: Obtaining ECAP recordings is also possible in the most apical region of the cochlea. However, differences can be observed depending on the region of the cochlea stimulated. Specifically, significant higher ECAP amplitude, lower thresholds and steeper amplitude growth function slopes have been observed in the apical region. These differences could be explained by the location of the stimulating electrode with respect to the neural tissue in the cochlea, a higher density, or an increased neural survival rate of neural tissue in the apex. Trial registration: The Clinical Investigation has the Competent Authority registration number DE/CA126/AP4/3332/18/05.

14 January 2004 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
IAIlona Anderson
Ilona Anderson
VWViktor Weichbold
Viktor Weichbold
PDPatrick S.C. D’hAese
Patrick S.C. D’hAese
JSJoanna Szuchnik
Joanna Szuchnik
MQManuel Sainz Quevedo
Manuel Sainz Quevedo
LPLucy Phillips
Lucy Phillips

1 January 2006 in International Journal of Audiology
Verified
Journal Article
Closed access
IAIlona Anderson
Ilona Anderson
WBWolf-Dieter Baumgartner
Wolf-Dieter Baumgartner
KBKlaus Böheim
Klaus Böheim
ANAlexander Nahler
Alexander Nahler
CAChristoph Arnolder
Christoph Arnolder
PDPatrick S.C. D'Haese
Patrick S.C. D'Haese
This study evaluated the use of landline and mobile phones in an international sample of cochlear implant users. A custom-designed survey was mailed to cochlear implant users from four different countries. A link to the survey was posted on the MED-EL website, with responses from a further six countries. Results from 196 surveys show that there is a significant shift from pre-operative non-use of a telephone to use of a telephone post-operatively. Seventy-one percent of MED-EL cochlear implant users are able to use a landline telephone to some extent and 54% are able to use a mobile phone to some extent. Talking to familiar speakers about familiar topics is the easiest listening condition on the telephone, and it is easier to recognize a voice using the landline. Many respondents found it difficult to make a call without some assistance. Most respondents could manage to call someone in an emergency, even on a mobile phone. Data obtained should provide useful information in the counselling and rehabilitation of cochlear implant recipients and candidates.

1 March 2004 in Cochlear Implants International
Verified
Journal Article
Closed access
ALArtur Lorens
Artur Lorens
AWAdam Walkowiak
Adam Walkowiak
APAnna Piotrowska
Anna Piotrowska
Henryk SkarzynskiHenryk Skarzynski
Henryk Skarzynski
IAIlona Anderson
Ilona Anderson

29 November 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
GMGriet Mertens
Griet Mertens
EAEllen Andries
Ellen Andries
AKAnja Kurz
Anja Kurz
DTDayse Távora-Vieira
Dayse Távora-Vieira
MCMiryam Calvino
Miryam Calvino
ALArtur Lorens
Artur Lorens
The study aimed to develop a consensus classification system for the reporting of sound localization testing results, especially in the field of cochlear implantation. Against the background of an overview of the wide variations present in localization testing procedures and reporting metrics, a novel classification system was proposed to report localization errors according to the widely accepted International Classification of Functioning, Disability and Health (ICF) framework. The obtained HEARRING_LOC_ICF scale includes the ICF graded scale: 0 (no impairment), 1 (mild impairment), 2 (moderate impairment), 3 (severe impairment), and 4 (complete impairment). Improvement of comparability of localization results across institutes, localization testing setups, and listeners was demonstrated by applying the classification system retrospectively to data obtained from cohorts of normal-hearing and cochlear implant listeners at our institutes. The application of our classification system will help to facilitate multi-center studies, as well as allowing better meta-analyses of data, resulting in improved evidence-based practice in the field.

1 February 2005 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
IAIlona Anderson
Ilona Anderson
MPMarkus Pitterl
Markus Pitterl
Henryk SkarzynskiHenryk Skarzynski
Henryk Skarzynski
RERobert Evans
Robert Evans
BGBenoit Godey
Benoit Godey
PDPatrick S.C. D’haese
Patrick S.C. D’haese