Marc Ferrari

Marc Ferrari

Auto-generated profile, based on publicly available information

Marc Ferrari

Lab. d'Astrophysique de Marseille (France)

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2018 in Optics Letters
Verified
Journal Article
Open access
PDF file
EMEduard MUSLIMOV
Eduard MUSLIMOV
EHEmmanuel Hugot
Emmanuel Hugot
MFMarc Ferrari
Marc Ferrari
TBThibault Behaghel
Thibault Behaghel
Gerard Rene LEMAITREGerard Rene LEMAITRE
Gerard Rene LEMAITRE
SLSimona Lombardo
Simona Lombardo
We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured reimaging three-mirror anastigmat as an example (f′=960 mm, F/5.3, ωx×ωy=4°×4°). By assuming that the image is focused on a toroidal detector surface and performing reoptimization, it becomes possible to obtain a notable gain in the image quality—up to 40% in terms of the spot root mean square radius. Through analytic computations and finite-element analysis, we demonstrate that this toroidal shape can be obtained by bending of a thinned detector in a relatively simple setup.

30 November 2022 in Journal of Neural Engineering
Verified
Journal Article
Open access
IRIsabelle Racicot
Isabelle Racicot
EMEduard Muslimov
Eduard Muslimov
SCSandrine Chemla
Sandrine Chemla
KBKévin Blaize
Kévin Blaize
MFMarc Ferrari
Marc Ferrari
FCFrédéric Chavane
Frédéric Chavane
Objective. Cortical activity can be recorded using a variety of tools, ranging in scale from the single neuron (microscopic) to the whole brain (macroscopic). There is usually a trade-off between scale and resolution; optical imaging techniques, with their high spatio-temporal resolution and wide field of view, are best suited to study brain activity at the mesoscale. Optical imaging of cortical areas is however in practice limited by the curvature of the brain, which causes the image quality to deteriorate significantly away from the center of the image. Approach. To address this issue and harness the full potential of optical cortical imaging techniques, we developed a new wide-field optical imaging system adapted to the macaque brain. Our system is composed of a curved detector, an aspherical lens and a ring composed of light emitting diodes providing uniform illumination at wavelengths relevant for the different optical imaging methods, including intrinsic and fluorescence imaging. Main results. The system was characterized and compared with the standard macroscope used for cortical imaging, and a three-fold increase of the area in focus was measured as well as a four-fold increase in the evenness of the optical quality in vivo. Significance. This new instrument, which is to the best of our knowledge the first use of a curved detector for cortical imaging, should facilitate the observation of wide mesoscale phenomena such as dynamic propagating waves within and between cortical maps, which are otherwise difficult to observe due to technical limitations of the currently available recording tools.

28 September 2004
Verified
Conference Paper
Open access
PDF file
FGFrederic Gonte
Frederic Gonte
NYNatalia Yaitskova
Natalia Yaitskova
PDPhilippe Dierickx
Philippe Dierickx
RKRobert Karban
Robert Karban
ACAlain Courteville
Alain Courteville
LMLuzma Montoya
Luzma Montoya
The point spread function of a segmented aperture is seriously affected by the misalignment of the segments. Stringent requirements apply to position sensors and their calibration. The Active Phasing Experiment (APE) will be a technical instrument aimed at testing possible phasing techniques for a European Giant Optical Telescope (EGOT) in a representative environment. It will also integrate simultaneous control of segmented and monolithic, active surfaces. A mirror composed of 61 hexagonal segments is conjugated to the primary mirror of the VLT. Each segment can be moved in piston, tip and tilt and can be controlled in open or closed loop. Three new types of Phasing Wave Front Sensors dedicated to the measurement of segmentation errors will be tested, evaluated and compared: a modified Mach-Zehnder sensor developed by the LAM and ESO, a Pyramid Sensor developed by Arcetri, and a Curvature Sensor developed by IAC. A reference metrology developed by FOGALE will be added to measure directly the deformation of the segmented mirror and check the efficiency of the tested wavefront sensors. This metrology will be based on a synthetic wavelength instantaneous phase stepping method. This experiment will first run in the laboratory with point-like polychromatic sources and a turbulence generator. In a second step, it will be mounted at a Nasmyth focus of a VLT unit telescope. These activities are included in a proposal to the European Commission for funding within Framework Program 6.

13 December 2020
Verified
Conference Paper
Closed access
EMEduard MUSLIMOV
Eduard MUSLIMOV
JBJean-Claude Bouret
Jean-Claude Bouret
CNCoralie Neiner
Coralie Neiner
MFMarc Ferrari
Marc Ferrari
SLSimona Lombardo
Simona Lombardo
MGMaëlle Le Gal
Maëlle Le Gal
SPIE Digital Library Proceedings

1 January 2026 in Review of Scientific Instruments
Verified
Journal Article
Open access
TST. Sieg-Letessier
T. Sieg-Letessier
AVA. Vivo
A. Vivo
FPF. Perrin
F. Perrin
JMJ. Marque
J. Marque
MFM. Ferrari
M. Ferrari
RBR. Barrett
R. Barrett
Maintaining optimal x-ray beam quality in accelerator-based light-sources requires mirrors with exceptional shape and surface precision. In practice, mirrors are often mounted in diverse orientations—such as in Kirkpatrick–Baez systems—where gravitational and mechanical effects may differ significantly from upward-facing metrology configurations. In this study, we use optical ray tracing to investigate alternative metrology geometries suitable for measuring side-facing and downward-facing mirrors. We propose a modified profilometry approach for use with the European Synchrotron Radiation Facility long trace profiler, in which beam folding optics are integrated beneath the scanning head to redirect the measurement beam. The approach combines a detailed optical model of the instrument implemented using ray-tracing, enabling accurate evaluation of the impact of motion-induced errors under realistic acquisition conditions. For downward-facing configurations, a promising solution was found experimentally, then characterized, and investigated with an analysis of the impact of alignment tolerance. While preliminary insights are provided for the side-facing setup, all proposed configurations exhibited sensitivity to motion errors of the scanning head, highlighting challenges for robust implementation.