1 December 2022 in Physics of Fluids
Experimentation research was conducted for studying the effect of blowing ratio (M) as well as cross flow Reynolds number (Rec) on distribution characteristics in film cooling effectiveness and heat transfer coefficient (h) on compound angle hole configuration with applying transient liquid crystal (TLC) technology. The distribution characteristics of discharge coefficient (Cd) were measured by the flow resistance experiment. The net heat flux reduction (NHFR) is applied for assessing the film cooling performance. Numerical simulation was carried out to present the flow features for analyzing the film cooling mechanism. Results demonstrate that the measured Cd shows upward tendency with the increase of M and is almost no change until M increases to a certain extent. At small M, the measured film cooling effectiveness is higher and descends with the increase of Rec. At the large M, the measured film cooling effectiveness is lower and presents the slight influence on the rises with the increase of Rec. The increase of M makes the measured h descend. The increase of Rec makes the measured h rise. And the NHFR shows the decreasing tendency with the increasing M. A The NHFR decreases in the increase of Rec at M=0.5 and M=2.0. The increase of Rec presents the slight influence on the NHFR under the condition of M =1.0.
1 July 2023 in Applied Thermal Engineering
14 August 2023 in International Journal of Thermal Sciences
1 October 2023 in Physics of Fluids
As a promising cooling technique, the double-wall cooling structure has been integrated into the design of advanced aeroengine high-temperature components. However, its widespread application in configurations with low pressure ratios between secondary flow and the main flow is hindered due to significant internal flow resistance. To address this issue, a novel low-resistance hollow pillar double-wall structure (NHDW) is developed. This study conducts conjugated heat transfer numerical simulations of NHDW and the traditional solid pillar double-wall structure (TSDW) for comparative analysis. Flow characteristics are examined to understand the sources of internal flow resistance and the coupling mechanism between internal and external heat transfer. The results demonstrate that the NHDW exhibits substantially lower flow resistance than the TSDW, with the total pressure loss dropping to approximately 1/3 of the corresponding TSDW under hole inclination angles of 30°, 60°, and 90°. The reduced internal flow resistance of the NHDW is attributed to the parallel bypass flow within the hollow pillar. Moreover, the overall cooling effectiveness (ϕ) of NHDW is enhanced by 9.2%–16.9% for different inclination angles at a blowing ratio of M = 1.0. Additionally, the interaction vortex structure on the mainstream side surface of the NHDW significantly improves the external cooling effectiveness, contributing to the overall enhancement of the cooling performance. Furthermore, a one-dimensional thermal resistance analysis method is introduced to distinguish the contributions of internal cooling and external film cooling. This analysis highlights the importance of external cooling enhancements in the novel structure.
9 November 2022 in Journal of Thermal Science