A high-sensitivity temperature sensor based on the enhanced Goos-Hänchen effect in a symmetrical metal-cladding waveguide is theoretically proposed and experimentally demonstrated. Owing to the high sensitivity of the ultrahigh-order modes, any minute variation of the refractive index and thickness in the guiding layer induced by the thermo-optic and thermal expansion effects will easily give rise to a dramatic change in the position of the reflected light. In our experiment, a series of Goos-Hänchen shifts are measured at temperatures varying from 50.0 °C to 51.2 °C with a step of 0.2 °C. The sensor exhibits a good linearity and a high resolution of approximately 510-3 oC. Moreover, there is no need to employ any complicated optical equipment and servo techniques, since our transduction scheme is irrelevant to the light source fluctuation.
We present a novel and simple optical structure, i.e., the symmetrical metal-cladding waveguide, in which a polymer layer is added into the guiding layer, for sensitive detection of chemical vapor by using the enhanced Goos-Hänchen (GH) shift (nearly a millimeter scale). Owing to the high sensitivity of the excited ultrahigh-order modes, the vapor-induced effect (swelling effect and refractive index change) in the polymer layer will lead to a dramatic variation of the GH shift. The detected GH shift signal is irrelevant to the power fluctuation of the incident light. The detection limit of 9.5 ppm for toluene and 28.5 ppm for benzene has been achieved.
A biosensor capable of highly sensitive detection of trace chromium (VI) with a simple hollow-core metal-cladding waveguide (HCMW) structure is theoretically modeled and experimentally demonstrated. Owing to the high sensitivity of the excited ultrahigh-order modes in the waveguide, a tiny variation of the extinction coefficients in the waveguide guiding layer where the chromate ions reacts with the diphenylcarbazide (DPC) can lead to a significant change of light intensity in the reflection spectrum. The experimental results indicate that using the proposed method, the chromium (VI) sensitivity detection limit can be as low as 1.2 nM, which represents a 16-fold improvement compared to the surface plasmon field-enhanced resonance light scattering (SP-RLS) method, and a 4-fold improvement compared to the flame atomic absorption spectrometry and fluorimetry spectroscopy, respectively.
An optical structure for relative humidity (RH) sensing based on a polyimide-coated symmetrical metal-cladding waveguide is proposed. The diffusion of water molecules into the polyimide film leads to a combined change of thickness and refractive index. Due to the high sensitivity of ultrahigh-order modes, the interaction between water molecules and polyimide will give rise to a dramatic variation in the reflected light intensity. Our optical RH sensor exhibits a good linearity and a high RH resolution of approximately 0.16% for RH values ranging from 36% to 76%. In addition, it provides a short response time, a favorable stability over a long period, and a small degree of hysteresis.