Wireless sensor networks have been shown to be a cost-effective monitoring tool for many applications on civil structures. Strain cycle monitoring for fatigue life assessment of railway bridges, however, is still a challenge since it is data intensive and requires a reliable operation for several weeks or months. In addition, sensing with electrical resistance strain gauges is expensive in terms of energy consumption. The induced reduction of battery lifetime of sensor nodes increases the maintenance costs and reduces the competitiveness of wireless sensor networks. To overcome this drawback, a signal conditioning hardware was designed that is able to significantly reduce the energy consumption. Furthermore, the communication overhead is reduced to a sustainable level by using an embedded data processing algorithm that extracts the strain cycles from the raw data. Finally, a simple software triggering mechanism that identifies events enabled the discrimination of useful measurements from idle data, thus increasing the efficiency of data processing. The wireless monitoring system was tested on a railway bridge for two weeks. The monitoring system demonstrated a good reliability and provided high quality data.
One of the interesting thermal management techniques for multi-core processors is core swapping. In this paper, using the published power data and floorplans for two modern high-performance processors, we employ the well-known HotSpot tool to perform the thermal simulation of the core swapping mechanism. Our transient simulations show that by using core swapping technique, it was possible to either minimize the hot spot temperature in the Ivy Bridge chip by 5°C or increase the operating frequency by 17% and maintain the same temperature as in the case without core swapping. We also derive an analytical model of the activity migration mechanism between two cores which may serve as a tool to calculate the swapping frequency given the desired maximal temperature drop. The model also allows for the correlation of the cooling effectiveness with the performance penalty induced by the swapping.
Heat transfer phenomena in nanostructures are supposed not to obey the classic Fourier heat transfer theory. Therefore, in order to verify this hypothesis nanostructures containing 100 nm-thin cavities filled with air or silicon dioxide were designed and manufactured. These structures include thin film platinum resistors located directly over and under the cavities. The resistors might serve either as heat sources or temperature sensors. This paper discusses in detail the experimental results of their thermal characterization and preliminary temperature measurements which are used to validate their thermal models. These experiments showed that it is possible to attain in the structures reasonable temperature gradients and temperature sensitivity allowing accurate temperature measurements with high temporal resolution.