Focused‐ion‐beam machining is a powerful process to fabricate complex nanostructures, often through a sacrificial mask that enables milling beyond the resolution limit of the ion beam. However, current understanding of this super‐resolution effect is empirical in the spatial domain and nonexistent in the temporal domain. This article reports the primary study of this fundamental tradespace of resolution and throughput. Chromia functions well as a masking material due to its smooth, uniform, and amorphous structure. An efficient method of in‐line metrology enables characterization of ion‐beam focus by scanning electron microscopy. Fabrication and characterization of complex test structures through chromia and into silica probe the response of the bilayer to a focused beam of gallium cations, demonstrating super‐resolution factors of up to 6 ± 2 and improvements to volume throughput of at least factors of 42 ± 2, with uncertainties denoting 95% coverage intervals. Tractable theory models the essential aspects of the super‐resolution effect for various nanostructures. Application of the new tradespace increases the volume throughput of machining Fresnel lenses by a factor of 75, enabling the introduction of projection standards for optical microscopy. These results enable paradigm shifts of sacrificial masking from empirical to engineering design and from prototyping to manufacturing.
17 May 2016 in Journal of Microelectromechanical Systems
Theoretical and experimental approaches verifying the fluidic operation of a partially shielded digital microfluidics device are presented in this paper. This paper is motivated by recent demand from the synthetic biology community for electro-wetting on dielectric (EWD) enabled in-droplet electroporation, but is generalizable to a range of EWD applications that require shielding structures to be patterned on the EWD. An electrode patterned in an additional metal layer on the insulator that supports EWD actuation reduces the effective strength of the EW force due to dielectric shielding at the droplet contact line. A numerical model was developed to predict the impact of the partially shielding electrode on threshold voltage, EW force, fluid velocity, and droplet transport time. Compared with a batch of devices lacking the extra electrode, the presence of the added metal layer resulted in a 29% increase in threshold voltage, an 82% increase in transport time, and a 44% decrease in average transport velocity. Each trend agrees with the simulation results obtained from the fluid transport model. These results support the development of design rules for microfluidic devices that require partially shielding metal layers to integrate with EWD device architectures.
Measurement errors can catastrophically bias parameter estimates in models to correlate nanoscale properties and structures, undercutting a foundation of nanoscience and nanotechnology. In a general solution to this latent problem, we derive a method-of-moments correction for least-squares estimates of correlative model parameters. Our correction applies to many relations of dependent and independent variables, subject to many types of measurement errors of the independent variable. Focusing on the prevalent power-law model to correlate optical intensity and nanoparticle size, we test the limits of accuracy of our correction and study the use of either reference size distributions or sizing uncertainty estimates to inform a measurement error model. We critically evaluate representative measurements of various nanoparticles, impacting the conclusions of several studies and changing expectations of intensity scaling exponents for nanoscale optical inferences. Our correction is immediately available, highly interpretable, and broadly applicable to gain reliable insights and prevent future mistakes.