In this work, a method of regenerative braking of an electric scooter was developed. Regenerative braking of electric vehicles is the basis for energy saving cars and environmental protection. A stand was made for the study of a magnets and an ionistor. In the proposed method, an ionistor is additionally connected in parallel to the battery, which charges faster than the battery, so the process of accelerating the electric vehicle after stopping also occurs faster. It should also be noted that if emergency braking is necessary to stop an electric vehicle, the driver can press the brake pedal and stop the car using brake pads. The paper investigates the method of the element base for the vehicle, as well as control. To develop this study, an electric scooter was chosen as an electric vehicle model. The dependences of the electric current on the operating time of the ionistor in three positions are determined. During the actual speed of the electric scooter corresponds to the controlled speed.
Lower-limb amputation remains a significant clinical and socio-economic challenge, while the high cost of microprocessor-controlled prostheses (MPKs) limits their widespread accessibility. This paper presents the design and preliminary laboratory-scale evaluation of a low-cost microprocessor-controlled ankle prosthesis intended as a feasibility-oriented alternative platform for future active prosthetic system development. Building upon the previously developed V1 mechanical architecture, an updated CAD model was created in the SolidWorks 2024 environment, and the kinematic configuration was refined using a ball-screw transmission (SFU1204-300) driven by a NEMA 17 stepper motor. The electronic control system integrates an ESP32 microcontroller, an MPU9250 inertial measurement unit (IMU), a limit switch for initial-position detection, and a WiFi-based REST API interface for communication and control. Laboratory no-load experiments demonstrated controlled positional behavior, repeatable angular response, and successful operation of the homing procedure within a motion range of 0–4200 motor steps. The prototype actively generated dorsiflexion–plantar flexion motion in the sagittal plane, while a passive inversion–eversion mechanism was incorporated and intended to improve structural adaptability. IMU-based measurements enabled preliminary monitoring of angular displacement and positional behavior during the experiments. The presented prototype represents an initial engineering feasibility study of a low-cost active ankle actuation architecture and provides a foundation for future investigations involving load-bearing experiments, biomechanical gait analysis, and closed-loop control implementation.
The object of this study is the diagnostic process of patients with suspected hemodynamically significant arrhythmia in emergency and telemedicine settings, where rapid and interpretable decision support is required. The problem addressed is the limited access to echocardiographic assessment in emergency and resource-constrained environments, where interpretable and computationally efficient alternatives are urgently needed, particularly for mobile and field-deployed applications. The main results show that machine learning models, such as XGBoost, achieved strong diagnostic performance (F1-score = 0.84, AUC = 0.91), while rule-based classifiers provided clinically interpretable accuracy. These results enabled partial compensation for the absence of echocardiography and contributed to reliable triage in acute and time-sensitive settings. This effectiveness stems from key features of the method: reliance on interpretable ECG features (tQRS, tRR, HR, and EF derived from tQRS/tRR) and low computational complexity, setting it apart from more opaque deep learning methods. The results are explained by the strong correlation between these features and both electrical and mechanical heart function, enabling hemodynamic assessment without imaging. This supports clinical trust in the algorithm’s outputs. The proposed approach is applicable in primary screening, emergency triage, telemedicine, and remote monitoring, combining accuracy with explainability and autonomy from imaging tools. Therefore, research on interpretable ECG-based detection of hemodynamically significant arrhythmias remains highly relevant, especially in settings lacking access to specialized diagnostics
This paper presents the kinematic design and experimental validation of a two-degree-of-freedom ankle mechanism based on stepper motor actuation and ball-screw transmission. The proposed system employs a hybrid architecture, combining actively controlled motion in the sagittal plane with passively compliant motion in the frontal plane. Experimental evaluation under no-load laboratory conditions demonstrated a strong linear relationship between motor steps and joint angle within an operating range of approximately ±22°, with coefficients of determination exceeding 0.97. The results confirm the predictability and repeatability of the kinematic transformation while revealing minor hysteresis effects associated with mechanical transmission. The proposed mechanism is intended as a validation platform for studying motion transformation in multi-DoF (degree-of-freedom) ankle systems, providing a basis for future work on load analysis, torque modeling, and closed-loop control.
25 January 2026 in Bulletin of Shakarim University. Technical Sciences
This paper presents an automated method for the classification of hemodynamically significant arrhythmias (HSA) based solely on electrocardiographic (ECG) features, without the use of additional imaging diagnostic techniques. The proposed approach relies on key ECG parameters, including QRS complex duration, RR intervals, and heart rate (HR). The study is based on data from the open-access MIT-BIH Arrhythmia Database, which contains multiple types of cardiac rhythm disturbances. A comparative analysis of arrhythmia classes was conducted, leading to the identification of diagnostically significant predictors associated with hemodynamic instability. Logical decision rules and a decision tree model were developed to enable automatic recognition of HSA and clinical risk stratification. The proposed algorithm demonstrates high interpretability and practical applicability for real-time monitoring systems. The results confirm that ECG-based features alone can be effectively used for preliminary detection of dangerous arrhythmias. The developed approach is especially valuable for telemedicine systems and healthcare facilities with limited access to expensive diagnostic equipment.