1 February 2018 in Plasma Sources Science and Technology
The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The electrons escaping through the extraction mirror of the ion source were detected with a secondary electron amplifier placed downstream from a dipole magnet serving as an electron spectrometer with 500 eV resolution. It was discovered that the EED in the range of 5–250 keV is strongly non-Maxwellian and exhibits several local maxima below 20 keV energy. It was observed that the most influential ion source operating parameter on the EED is the magnetic field strength, which affected the EED predominantly at energies less than 100 keV. The effects of the microwave power and frequency, ranging from 100 to 600 W and 11 to 14 GHz, respectively, on the EED were found to be less significant. The presented technique and experiments enable the comparison between direct measurement of the EED and results derived from Bremsstrahlung diagnostics, the latter being severely complicated by the non-Maxwellian nature of the EED reported here. The role of RF pitch angle scattering on electron losses and the relation between the EED of the axially escaping electrons and the EED of the confined electrons are discussed.
13 May 2020 in Plasma Physics and Controlled Fusion
After a basic introduction to the quasilinear theory of electron-cyclotron interaction in a mirror magnetic field, we develop a unified model that describes the formation of a non-thermal electron distribution function under the combined action of resonant plasma heating from external mono- or bi-chromatic waves and kinetic instabilities in the electron-cyclotron frequency range.
19 August 2011 in Plasma Sources Science and Technology
1 October 2012 in Journal of Instrumentation
1 December 2019 in Review of Scientific Instruments
A new experimental facility named GISMO (Gasdynamic Ion Source for Multipurpose Operation) was constructed at the IAP RAS to continue investigations in the field of gasdynamic ion sources. The source utilizes 28 GHz/10 kW gyrotron radiation for heating magnetically confined plasma. Magnetic field configuration provided by a fully permanent magnet system is much like a simple mirror trap. The GISMO source is aimed at the production of bright ion beams with hundreds of milliamperes current. The facility has been tested for continuous-wave (CW) operation with 2 kW of heating power to check durability of a microwave injection system and the plasma chamber. A 2-electrode extraction system with an integrated Einzel lens was designed for a formation of CW high current beam with up to 100 kV accelerating voltage. The first results on ion beam production at GISMO are presented together with the general progress status of the facility.
1 February 2008 in Review of Scientific Instruments
A careful study of pulsed mode operation of the PHOENIX electron cyclotron resonance (ECR) ion source has clearly demonstrated the reality of an unexpected transient current peak, occurring at the very beginning of the plasma breakdown. This regime was named the preglow, as an explicit reference to the afterglow occurring at the microwave pulse end. After the transient preglow peak, the plasma regime relaxes to the classical steady state one. Argon preglow experiments performed at LPSC are presented. A theoretical model of ECR gas breakdown in a magnetic trap, developed at IAP, showing satisfactory agreement with the experimental results is suggested.