A careful study of pulsed mode operation of the PHOENIX electron cyclotron resonance (ECR) ion source has clearly demonstrated the reality of an unexpected transient current peak, occurring at the very beginning of the plasma breakdown. This regime was named the preglow, as an explicit reference to the afterglow occurring at the microwave pulse end. After the transient preglow peak, the plasma regime relaxes to the classical steady state one. Argon preglow experiments performed at LPSC are presented. A theoretical model of ECR gas breakdown in a magnetic trap, developed at IAP, showing satisfactory agreement with the experimental results is suggested.
6 September 2018 in Journal of Physics D: Applied Physics
The study of the gas discharge in quasioptical beams of electromagnetic radiation of the terahertz (THz) frequency band is attractive for fundamental and applied research. The study of this discharge was made possible by the emergence of unique and reliable sources of radiation of the THz frequency band. Electrovacuum radiation sources of THz band (gyrotrons) have been created at the Institute of Applied Physics (IAP RAS) (Nizhny Novgorod) with a power order of 100 kW in pulsed mode of operation (pulse duration ~ several dozens of µ s) and a kilowatt in continuous mode, and investigations of gas discharge phenomena in various gases have been started. Even the first experimental studies of the discharge in noble gases (argon) showed a significant difference in the THz discharge from the discharge at lower frequencies, even in the dynamics of discharge glow. The maximum of the discharge glow was observed after the end of the THz pulse and the afterglow duration was hundreds of microseconds. This paper is devoted to the theoretical and experimental study of the breakdown thresholds of various gases by radiation at 263 and 670 GHz and the study of discharge dynamics in noble and molecular gases under the action of 670 GHz radiation.
The gasdynamic electron cyclotron resonance (ECR) ion source is a type of the device in which the ionization efficiency is achieved primarily due to a high plasma density. Because of a high particle collision rate, the confinement is determined by a gasdynamic plasma outflow from a magnetic trap. Due to high efficiency of resonant heating, electrons gain energy significantly higher than that in inductively or capacitively coupled plasmas. As a consequence of such a parameter combination, the gasdynamic ECR plasma can be a unique source of low to medium charged ions, providing a high current and an ultimate quality of an ion beam. One of the most demanded directions of its application today is a development of high-current proton injectors for modern accelerators and neutron sources of different intensities. Special plasma parameters allow for the use of diagnostic techniques, traditional for multiply charged ECR plasmas as well as for other types of discharges with a high plasma density. Among the additional techniques, one can mention the methods of numerical simulation and reconstruction of the plasma density and temperature from the parameters of the extracted ion beams. Another point is that the high plasma density makes it possible to measure it from the Stark broadening of hydrogen lines by spectroscopy of plasma emission in the visible range, which is a fairly convenient non-invasive diagnostic method. The present paper discusses the main physical aspects of the gasdynamic ECR plasma, suitable diagnostic techniques, and possibilities and future prospects for its various applications.
17 July 2020 in IEEE Transactions on Terahertz Science and Technology
Unlike synchrotrons with multiple beamlines, free electron lasers (FELs) are single-beam facilities, which nevertheless have a number of endstations. The latter requires development of complex radiation transport line, which should be efficient enough to avoid scaling down the FEL capabilities. Keeping the beam shape and radiation power level along the beamline is a challenge because the total length of the FEL radiation transport line can exceed a hundred meters. The FELs around the world differs each other in both radiation parameters and endstations layout requiring individual design of their radiation transport lines. In this work we describe the 120-m beamline for transporting the radiation of the Novosibirsk free electron laser facility (NovoFEL), consisting of three FELs of the terahertz (THz), far-infrared, and mid-infrared ranges. The radiation of these three FELs is directed to the same beam transport channel, which is able to deliver the radiation to any of 14 endstations already commissioned. To compare the expected beam parameters with the actual ones, the radiation intensity distribution was measured in a number of places of the beamline that are THz radiation outputs for some endstations. Possible causes of the parameters mismatching observed for distant endstations are discussed. The problem of radiation absorption by water vapor is considered in detail.
This work was carried out in a frame of the study of the discharge propagation in noble gases in focused beams of the terahertz frequency range radiation. A 40 kW at 670 GHz pulsed gyrotron was used as a source of heating radiation. The propagation velocity of the discharge front in various noble gases (argon, krypton, and a helium–argon mixture) was measured over a wide pressure range (from several atmospheres to several Torr, depending on the type of gas). It is shown that the discharge propagation velocity decreases with increasing gas pressure. Moreover, the velocity decreases with an increase in the atomic mass of the gas from several units of 107 cm/s in the case of a helium–argon mixture to 106–105 cm/s (depending on pressure) in the case of krypton over the entire pressure range. Measurements of the discharge propagation velocity were carried out in several ways: from instant snapshots from the high-speed camera and images of the discharge from a streak-camera. The mechanisms responsible for the propagation of the discharge are currently the subject of further research.