V. G. Beketov

V. G. Beketov

Auto-generated profile, based on publicly available information

V. G. Beketov

Volgodonsk Engineering Technical Institute the branch of National Research Nuclear University «MEPhI

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2020 in Nondestructive Testing and Evaluation
Verified
Journal Article
Closed access
AAA. I. Alwaheba
A. I. Alwaheba
VSVitaly Surin
Vitaly Surin
TIT. E. Ivanova
T. E. Ivanova
OIO. V. Ivanov
O. V. Ivanov
VBV. G. Beketov
V. G. Beketov
VGV. А. Goshkoderov
V. А. Goshkoderov
Scanning contact potentiometry (SCP) is a nondestructive method used for defects detection, and for determining the location coordinates of defects in welded joints. This paper evaluates the accuracy of SCP method in detecting defects and localising them in welded steel plates. The effectiveness of the SCP method was evaluated using sample of steel 321 H plates (Chromium–Nickel–titanium stainless steel), where sample plates were welded by means of manual arc welding, dimension of each 200 × 110 × 13.5 mm. After welding, welded sample was inspected using an X-ray radiographic testing system. In order to investigate SCP capabilities, plotted potentiograms were compared with the corresponding X-ray radiograph image. Furthermore, SCP signals were analysed using discrete Fourier transform. Experimental outcomes proved that defects can be detected by SCP technique more accurate comparative to X-ray. Also it is considered an inexpensive comparable to X-ray and ultrasound non-destructive testing methods. As a result, SCP may substitute some destructive or non-destructive testing methods.


27 March 2024 in Global Nuclear Safety
Verified
Journal Article
Open access
PDF file
ИМИ. В. Мельников
И. В. Мельников
VNV. V. Nechitailov
V. V. Nechitailov
VBV. G. Beketov
V. G. Beketov
IPI. Yu. Popova
I. Yu. Popova
NSN. A. Snitko
N. A. Snitko
Due to the variety of defects that arise in electrical machines, it is necessary to use more effective methods for monitoring their condition. All over the world research and development of new means and methods for monitoring powerful electrical machines during their operation is underway. Some examples of recent advances are vibration diagnostic methods for assessing the compaction of components inside a transformer, acoustic and electrical systems for monitoring partial discharges, data processing using digital methods, and new sensors for continuous monitoring of gases and moisture in oil, as well as hot spot temperatures. Additionally, thermal imaging testing of power equipment is also an important tool to ensure reliable operation. It is believed that the most effective method is gas chromatographic oil analysis, which can identify most defects in oil-filled equipment. During the operation of powerful electrical machines, the use of existing non-destructive testing methods does not allow a complete assessment of the condition of the main parts of the equipment, as an analysis of damage locations shows, 25% are damage to the core and windings. Effective monitoring of the condition and determination of the performance of transformers is of particular importance, since they are key elements in the operation of nuclear power plants. The paper considers the possibility of using the eddy current testing method; determining a defect in magnetic core steel is based on fixing the unevenness of the magnetic field on the horizontal or vertical planes of a yoke or rod consisting of electrical steel plates. Monitoring and evaluating the functioning of existing equipment, detecting deficiencies in the early stages of their development, when repair costs are still minimal, and preventing emergency failures become a priority. In accordance with the growth rate of detected deficiencies, monitoring is carried out from time to time or continuously, the maximum number of monitored characteristics is achieved when the transformer is fully tested to determine its functionality.

1 March 2017 in Global Nuclear Safety
Verified
Journal Article
Closed access
VRV.A. Rudenko
V.A. Rudenko
STS.A. Tomilin
S.A. Tomilin
VBV.G. Beketov
V.G. Beketov

1 September 2017 in Global Nuclear Safety
Verified
Journal Article
Closed access
YSYu.S. Sysoev
Yu.S. Sysoev
ASA. A. Salnikov
A. A. Salnikov
ACA.V. Chernov
A.V. Chernov
VBV.G. Beketov
V.G. Beketov

1 June 2020 in Global Nuclear Safety
Verified
Journal Article
Closed access
AAA. I. Alwaheba
A. I. Alwaheba
VSVitaly Surin
Vitaly Surin
TIT. E. Ivanova
T. E. Ivanova
OIO. V. Ivanov
O. V. Ivanov
VBV. G. Beketov
V. G. Beketov
VGV. A. Goshkoderov
V. A. Goshkoderov
Scanning contact potentiometry (SCP) is used for defects detection and for determine the coordinates of the defects localized in welded joints. Studied samples are welded by manual arc welding of two halves austenitic steel 321H (Chromium-Nickel-titanium stainless Steel) dimension of each 200×110×13.5 mm. Thereafter welding, seam width is about 12 mm. Subsequently welded sample is inspected using X-ray radiographic testing system. In order to compare techniques capabilities, plotted potentiograms and weld radiograph are compared. Experimental outcomes prove that defects can be detected by SCP technique. SCP results are complied with mathematical signal analysis of defects. This method may substitute some destructive or nondestructive methods.