19 March 2020 in Nondestructive Testing and Evaluation
Scanning contact potentiometry (SCP) is a nondestructive method used for defects detection, and for determining the location coordinates of defects in welded joints. This paper evaluates the accuracy of SCP method in detecting defects and localising them in welded steel plates. The effectiveness of the SCP method was evaluated using sample of steel 321 H plates (Chromium–Nickel–titanium stainless steel), where sample plates were welded by means of manual arc welding, dimension of each 200 × 110 × 13.5 mm. After welding, welded sample was inspected using an X-ray radiographic testing system. In order to investigate SCP capabilities, plotted potentiograms were compared with the corresponding X-ray radiograph image. Furthermore, SCP signals were analysed using discrete Fourier transform. Experimental outcomes proved that defects can be detected by SCP technique more accurate comparative to X-ray. Also it is considered an inexpensive comparable to X-ray and ultrasound non-destructive testing methods. As a result, SCP may substitute some destructive or non-destructive testing methods.
22 February 2021 in EPJ Web of Conferences
This study presents the results of electrophysical non-destructive testing of collectors welded joints to the body of steam generators PGV 1000Mof the reactor WWER-1000. The studied steam generators located in the Resource Сenter of National Research Nuclear University MEPhI at the site of reactors construction factory “Atommash” in Volgodonskcity-Russia. The primary loop collector was welded to the body of steam generators PGV 1000Mand the technical condition of welded joints was investigated by electrophysical non-destructive testing (EPhT). In steam generatorsmay appear corrosion and cracks due to corrosive environment and effect of stresses however,EPhTcan detect early stages of cracks. The study highlights the theoretical part of electrophysical diagnostics and control method, using modern mathematical signals analysis, and issues related to the practical implementation of EPhT in the factory. The novel alternative method of non-destructive testing can be used in diagnostic oil and gas pipelines, elements of complex technical structures and industrial equipment. It can be used in many industries where it is necessary to process control of the entire structure or its individual parts under operating conditions. Based on control results, potentiograms were constructed for various structural levels of the diagnostic signal. The results of controlled welded joints in steam generators showed their satisfactory condition.
1 June 2020 in Global Nuclear Safety
Scanning contact potentiometry (SCP) is used for defects detection and for determine the coordinates of the defects localized in welded joints. Studied samples are welded by manual arc welding of two halves austenitic steel 321H (Chromium-Nickel-titanium stainless Steel) dimension of each 200×110×13.5 mm. Thereafter welding, seam width is about 12 mm. Subsequently welded sample is inspected using X-ray radiographic testing system. In order to compare techniques capabilities, plotted potentiograms and weld radiograph are compared. Experimental outcomes prove that defects can be detected by SCP technique. SCP results are complied with mathematical signal analysis of defects. This method may substitute some destructive or nondestructive methods.
1 June 2026 in Biomedical Materials
While fused deposition modelling (FDM) of polyether ether ketone (PEEK) has achieved regulatory acceptance and is utilized for patient-specific orthopaedic implants, the obligatory terminal sterilization via gamma irradiation raises concerns regarding polymer aging and structural degradation. This study investigates the spatiotemporal effects of gamma sterilization on the macroscopic mechanical integrity and medium-term in vivo biocompatibility of 3D-printed PEEK. Standard specimens were fabricated using a Taguchi L9 orthogonal array, manipulating key FDM parameters (layer thickness, print speed, number of shells, and raster width). To simulate a worst-case scenario of accelerated aging and free radical-induced degradation, specimens were subjected to 50 kGy of gamma irradiation and mechanically evaluated over a two-month period. In parallel, to assess clinical safety, an extensive in vivo study was conducted utilizing 81 BALB/c rats over 12 weeks. Specimens sterilized at the standard clinical dose of 25 kGy were implanted subcutaneously and compared with autoclaved controls. Mechanical testing revealed complex, nonlinear interactions between printing parameters and post-irradiation time, indicating simultaneous cross-linking and delayed oxidative chain scission mechanisms that ultimately preserved functional strength. Crucially, histological evaluation at 4, 8, and 12 weeks demonstrated excellent in vivo biocompatibility, characterized by minimal acute inflammation, rare foreign body giant cells, and the formation of a healthy, organized fibrous capsule, irrespective of the sterilization method. These findings suggest that 3D-printed PEEK maintains its structural resilience and favourable immunomodulatory profile post-gamma sterilization, successfully bridging the gap between additive manufacturing parameters and safe clinical translation.