The development of modern power systems is directly related to changes in the traditional principles of management, planning, and monitoring of electrical modes. The mass introduction of renewable energy sources and control devices based on power electronics components contributes to changing the nature of the flow of transient and quasi-established electrical modes. In this area, the problem arises of conducting a more accurate and rapid assessment of the parameters of the electrical regime using synchronized vector measurement devices. The paper presents an extensive meta-analysis of the modern applications of phasor measurement units (PMUs) for monitoring, emergency management and protection of power systems. As a result, promising research directions, the advantages and disadvantages of the existing approaches to emergency management, condition assessment, and relay protection based on PMUs are identified.
The article considers the electric energy flow and energy losses calculation problem on the basis of energy meter data using the scheme of the electrical network. The problem is referred to as the energy flow problem. A mathematical model of energy flow problem (EFP) is based on equations of energy balances in nodes and branches of the network, these equations are true with any state or topology network changes. The energy flow problem is proposed to be solved on the basis of state estimation approaches. General challenges and differences in solving the conventional state estimation problem and the energy flow problem are considered. These include the observability analysis, a bad data problem as well as the iterative calculation convergence.
One of the tasks in the operation of electric power systems is the correct functioning of the protection system and emergency automation algorithms. Instrument voltage and current transformers, operating in accordance with the laws of electromagnetism, are most often used for information support of the protection system and emergency automation algorithms. Magnetic core saturation of the specified current transformers can occur during faults. As a result, the correct functioning of the protection system and emergency automation algorithms is compromised. The consequences of current transformers saturation are mostly reflected in the main protections of network elements operating on a differential principle. This work aims to consider the analysis of current transformer saturation detection methods. The problem of identifying current transformer saturation is reduced to binary classification, and methods for solving the problem based on artificial neural networks, support vector machine, and decision tree algorithms are proposed. Computational experiments were performed, and their results were analyzed with imbalanced (dominance of the number of current transformer saturation modes over the number of modes with its normal operation) and balanced classes 0 (no current transformer saturation) and 1 (current transformer saturation).
Nontechnical losses of electrical energy (NTLEE) have been a persistent issue in both the Russian and global electric power industries since the end of the 20th century. Every year, these losses result in tens of billions of dollars in damages. Promptly identifying unscrupulous consumers can prevent the onset of NTLEE sources, substantially reduce the amount of NTLEE and economic damages to network grids, and generally improve the economic climate. The contemporary advancements in machine learning and artificial intelligence facilitate the identification of NTLEE sources through anomaly detection in energy consumption data. This article aims to analyze the current efficacy of computational methods in locating, detecting, and identifying nontechnical losses and their origins, highlighting the application of neural network technologies. Our research indicates that nearly half of the recent studies on identifying NTLEE sources (41%) employ neural networks. The most utilized tools are convolutional networks and autoencoders, the latter being recognized for their high-speed performance. This paper discusses the main metrics and criteria for assessing the effectiveness of NTLEE identification utilized in training and testing phases. Additionally, it explores the sources of initial data, their composition, and their impact on the outcomes of various algorithms.
The allocation of electrical energy meters in power systems is given a careful consideration. Observability is understood as the ability of electrical energy distribution calculation based on existing measurements. The problem definition is given in terms of the application of the state estimation theory. State equations for energy distribution problem differ from the similar ones for power distribution problem. Therefore, these problems have different criteria of observability. Numerical characteristics of the observability degree of electrical energy flows as well as recommendations for system accounting redundancy increase are given.
In this paper, the application of the Newton's method in optimization for power flow calculation is considered. Convergence conditions of the suggested method using an example of a three-machine system are investigated. It is shown, that the method allows to calculate non-existent state points and automatically pulls them onto the boundary of power flow existence domain. A combined method which is composed of Newton-Raphson method and Newton's method in optimization is presented in the paper.