Airborne respiratory diseases such as COVID-19 pose significant challenges to public transportation. Several recent outbreaks of SARS-CoV-2 indicate the high risk of transmission among passengers on public buses if special precautions are not taken. This study presents a combined experimental and numerical analysis to identify transmission mechanisms on an urban bus and assess strategies to reduce risk. The effects of the ventilation and air-conditioning systems, opening windows and doors, and wearing masks are analyzed. Specific attention is paid to the transport of submicron- and micron-sized particles relevant to typical respiratory droplets. High-resolution instrumentation was used to measure size distribution and aerosol response time on a campus bus of the University of Michigan under these different conditions. Computational fluid dynamics was employed to measure the airflow within the bus and evaluate risk. A risk metric was adopted based on the number of particles exposed to susceptible passengers. The flow that carries these aerosols is predominantly controlled by the ventilation system, which acts to uniformly distribute the aerosol concentration throughout the bus while simultaneously diluting it with fresh air. The opening of doors and windows was found to reduce the concentration by approximately one half, albeit its benefit does not uniformly impact all passengers on the bus due to the recirculation of airflow caused by entrainment through windows. Finally, it was found that well fitted surgical masks, when worn by both infected and susceptible passengers, can nearly eliminate the transmission of the disease.
The effects of a broad range of fuel injection strategies on thermal efficiency and engine-out emissions (CO, total hydrocarbons, NOx and particulate number) were studied for gasoline and ethanol fuel blends. A state-of-the-art production multi-cylinder turbocharged gasoline direct injection engine equipped with piezoelectric injectors was used to study fuels and fueling strategies not previously considered in the literature. A large parametric space was considered including up to four fuel injection events with variable injection timing and variable fuel mass in each injection event. Fuel blends of E30 (30% by volume ethanol) and E85 (85% by volume ethanol) were compared with baseline E0 (reference grade gasoline). The engine was operated over a range of loads with intake manifold absolute pressure from 800 to 1200 mbar. A combined application of ethanol blends with a multiple injection strategy yielded considerable improvement in engine-out particulate and gaseous emissions while maintaining or slightly improving engine brake thermal efficiency. The weighted injection spread parameter defined in this study, combined with the weighted center of injection timing defined in the previous literature, was found well suited to characterize multiple injection strategies, including the effects of the number of injections, fuel mass in each injection and the dwell time between injections.
28 March 2017 in SAE International Journal of Engines
Syngas (synthesis gas) aided combustion from various fuel reforming strategies is of increasing interest in boosted lean burn SI engines due to its impact on dilution tolerance and knock resistance. Due to the interest in reformed fuels, more concrete understanding of how to leverage syngas supplementation under various lean conditions is essential to optimize engine performance and derive the most benefit from the availability of syngas in the combustion process. While the impact of syngas supplementation on combustion stability has been studied adequately, detailed understanding of the impact of syngas on knocking is still limited. Hence, this study investigates the effect of syngas (H2/CO) addition on knock tendency under boosted EGR (Exhaust Gas Recirculation) and air diluted conditions. Syngas amount is controlled on an energy basis from 0% to 15% to compare the difference between EGR and air dilution. At first, several knock quantification methods are compared, and a suitable knock index and guideline are selected. Knocking tendencies with respect to the frequency, combustion phasing, and burn duration are analyzed based on observed engine knock. Also, the thermal efficiency and emissions difference are discussed as well. The results show that with increasing the syngas supplementation ratio, knocking is strongly suppressed, and the effect is more beneficial with EGR dilution than with air dilution.
16 March 2022 in International Journal of Engine Research
EGR is a useful means to improve fuel economy in spark-ignited gasoline engines, especially under part-load conditions by means of reducing throttling losses. There is also a significant reduction in NOx emissions due to the reduced peak cylinder temperatures. However, the ability of conventional spark ignition systems to reliably ignite dilute mixtures limits the dilution tolerance due to the onset of combustion instability. In this study, an active pre-chamber system was evaluated at part load condition with various EGR rates using a regular grade full boiling range gasoline. A premixed air-fuel mixture was supplied to the pre-chamber, which assists in scavenging the residual mass fractions to enable reliable ignition of EGR dilute mixtures in the main combustion chamber. A range of pre-chamber injection, air-fuel mixture formulation, and ignition timing strategies were evaluated during the EGR sweeps. In addition, 0-D and 1-D simulations were conducted in GT-Power to assess the thermodynamic state and composition in the pre-chamber, as well as estimate the jet momentum at the various dilution rates. The active pre-chamber extended the EGR dilution limit from 20% for conventional SI to above 30%, with a higher pre-chamber flow rate (more scavenging) resulting in increased combustion stability. A tradeoff between the jet momentum and spark timing was observed when analyzing the GT-Power simulations and the pre-chamber jet momentum was found to decrease with increasing EGR rate. At unstable high EGR operation, no relation could be found between the pre-chamber indicated data and main chamber combustion stability.
5 April 2016 in SAE International Journal of Materials and Manufacturing
Exhaust gas recirculation (EGR) coolers are used on diesel engines to reduce peak in-cylinder flame temperatures, leading to less NOx formation during the combustion process. There is an ongoing concern with soot and hydrocarbon fouling inside the cold surface of the cooler. The fouling layer reduces the heat transfer efficiency and causes pressure drop to increase across the cooler. A number of experimental studies have demonstrated that the fouling layer tends to asymptotically approach a critical height, after which the layer growth ceases. One potential explanation for this behavior is the removal mechanism derived by the shear force applied on the soot and hydrocarbon deposit surface. As the deposit layer thickens, shear force applied on the fouling surface increases due to the flow velocity growth. When a critical shear force is applied, deposit particles start to get removed. In this study, a 1-D model is developed to predict effectiveness drop and fouling layer distribution across the cooler. To model the removal mechanism, experiments described in Part 1 of this paper were conducted. Removal of particles was measured by blowing compressed air in various conditions through the fouled tube from the shell-in-tube type EGR cooler rig. A deposit removal regression equation was developed using the blow out experiment data, which was incorporated into the model. The resulting model showed good correspondence with the experimental data, indicating that removal mechanism improves the prediction of modeling. For the first time, the new model with the empirically derived removal function is able to predict the trend of thermal effectiveness stabilization observed in experiments.