Dolores del Campo

Dolores del Campo

Auto-generated profile, based on publicly available information

Dolores del Campo

Centro Español de Metrología, Alfar 2, 28760 Tres Cantos, Spain

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2016 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
EWEmma Woolliams
Emma Woolliams
KAK. Anhalt
K. Anhalt
MBM. Ballico
M. Ballico
PBP. Bloembergen
P. Bloembergen
FBF. Bourson
F. Bourson
ZYZ. Yuan
Z. Yuan
The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.

1 December 2015 in Meteorological Applications
Verified
Journal Article
Open access
PDF file
AMAndrea Merlone
Andrea Merlone
GLG. Lopardo
G. Lopardo
Francesca SannaFrancesca Sanna
Francesca Sanna
SBS. Bell
S. Bell
RBR. Benyon
R. Benyon
RUR. Underwood
R. Underwood
The study describes significant outcomes of the ‘Metrology for Meteorology’ project, MeteoMet, which is an attempt to bridge the meteorological and metrological communities. The concept of traceability, an idea used in both fields but with a subtle difference in meaning, is at the heart of the project. For meteorology, a traceable measurement is the one that can be traced back to a particular instrument, time and location. From a metrological perspective, traceability further implies that the measurement can be traced back to a primary realization of the quantity being measured in terms of the base units of the International System of Units, the SI. These two perspectives reflect long‐standing differences in culture and practice and this project – and this study – represents only the first step towards better communication between the two communities.The 3 year MeteoMet project was funded by the European Metrology Research Program (EMRP) and involved 18 European National Metrological Institutes, 3 universities and 35 collaborating stakeholders including national meteorology organizations, research institutes, universities, associations and instrument companies.The project brought a metrological perspective to several long‐standing measurement problems in meteorology and climatology, varying from conventional ground‐based measurements to those made in the upper atmosphere. It included development and testing of novel instrumentation as well as improved calibration procedures and facilities, instrument intercomparison under realistic conditions and best practice dissemination. Additionally, the validation of historical temperature data series with respect to measurement uncertainties and a methodology for recalculation of the values were included.

5 February 2018 in Metrologia
Verified
Journal Article
Closed access
PDF file
JFJoachim Fischer
Joachim Fischer
BFBernd Fellmuth
Bernd Fellmuth
CGChristof Gaiser
Christof Gaiser
TZThorsten Zandt
Thorsten Zandt
LPLaurent Pitre
Laurent Pitre
DCDolores del Campo
Dolores del Campo
The International Committee for Weights and Measures (CIPM), at its meeting in October 2017, followed the recommendation of the Consultative Committee for Units (CCU) on the redefinition of the kilogram, ampere, kelvin and mole. For the redefinition of the kelvin, the Boltzmann constant will be fixed with the numerical value 1.380 649 × 10 −23 J K −1 . The relative standard uncertainty to be transferred to the thermodynamic temperature value of the triple point of water will be 3.7 × 10 −7 , corresponding to an uncertainty in temperature of 0.10 mK, sufficiently low for all practical purposes. With the redefinition of the kelvin, the broad research activities of the temperature community on the determination of the Boltzmann constant have been very successfully completed. In the following, a review of the determinations of the Boltzmann constant k , important for the new definition of the kelvin and performed in the last decade, is given.

18 January 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
AMAndrea Merlone
Andrea Merlone
Francesca SannaFrancesca Sanna
Francesca Sanna
GBGaber Beges
Gaber Beges
SBS Bell
S Bell
GBG Beltramino
G Beltramino
ACAlicia Gonzalez Calvo
Alicia Gonzalez Calvo
Launched in 2011 within the European Metrology Research Programme (EMRP) of EURAMET, the joint research project ‘MeteoMet’—Metrology for Meteorology—is the largest EMRP consortium; national metrology institutes, universities, meteorological and climate agencies, research institutes, collaborators and manufacturers are working together, developing new metrological techniques, as well as improving existing ones, for use in meteorological observations and climate records. The project focuses on humidity in the upper and surface atmosphere, air temperature, surface and deep-sea temperatures, soil moisture, salinity, permafrost temperature, precipitation, and the snow albedo effect on air temperature. All tasks are performed using a rigorous metrological approach and include the design and study of new sensors, new calibration facilities, the investigation of sensor characteristics, improved techniques for measurements of essential climate variables with uncertainty evaluation, traceability, laboratory proficiency and the inclusion of field influencing parameters, long-lasting measurements, and campaigns in remote and extreme areas. The vision for MeteoMet is to take a step further towards establishing full data comparability, coherency, consistency, and long-term continuity, through a comprehensive evaluation of the measurement uncertainties for the quantities involved in the global climate observing systems and the derived observations. The improvement in quality of essential climate variables records, through the inclusion of measurement uncertainty budgets, will also highlight possible strategies for the reduction of the uncertainty. This contribution presents selected highlights of the MeteoMet project and reviews the main ongoing activities, tasks and deliverables, with a view to its possible future evolution and extended impact.

25 May 2017 in Metrologia
Verified
Journal Article
Closed access
PDF file
DLD H Lowe
D H Lowe
ATA D W Todd
A D W Todd
RBR Van Den Bossche
R Van Den Bossche
PBP Bloembergen
P Bloembergen
KAK Anhalt
K Anhalt
ZYZ Yuan
Z Yuan
The eutectic alloys rhenium–carbon, platinum–carbon and cobalt–carbon have been proposed as reference standards for thermometry, with temperature and uncertainty values specified within the mise en pratique of the definition of the kelvin. These alloys have been investigated in a collaboration of eleven national measurement institutes and laboratories. Published results reported the point-of-inflection in the melting curve with extremely low uncertainties. However, to be considered as standards it is necessary to stipulate what phenomenon a temperature value has been ascribed to; specifically, this should be a thermodynamic state. Therefore, the data have been further evaluated and the equilibrium liquidus temperatures determined based on a consideration of limits and assuming a rectangular probability distribution. The values are: for rhenium–carbon 2747.91 ± 0.44 K, for platinum–carbon 2011.50 ± 0.22 K and for cobalt–carbon 1597.48 ± 0.14 K, with uncertainties at approximately a 95% coverage probability. It is proposed that these values could be used as the basis of thermodynamic temperature measurement at high temperatures (above 1300 K).

12 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Pablo CastroPablo Castro
Pablo Castro
RAMON LECUNARAMON LECUNA
RAMON LECUNA
Mario MananaMario Manana
Mario Manana
MMMaria Jose Martin
Maria Jose Martin
DCDolores del Campo
Dolores del Campo
Efficiency in power lines operation is becoming more crucial as the electrification increases and more renewable energies are connected into the grid. New methods and sensors are being added to create smart grids to face these challenges and conductor temperature sensors are one of them. Contact temperature sensors have several problems regarding safety and electronic damage due to the electromagnetic fields induced on the conductors. The goal of this paper is to describe an infrared temperature measurement sensor and to compare contact and non-contact temperature measurements to estimate the temperature of power lines. Measurements were done for almost a year, storing around 150,000 measures of contact and infrared thermometers for many different weather and load conditions. The results conclude that the infrared system can be successfully used to control the temperature of the overhead conductor within a range of less than 4 ∘C difference with respect to contact temperature methods for the 88% of the samples and less than 6 ∘C for the 99%.