Qizhe Zhang

Mr. Qizhe Zhang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
FLFangcheng Lv
Fangcheng Lv
KMKang Ma
Kang Ma
HGHui Geng
Hui Geng
SWShenghui Wang
Shenghui Wang
ZLZhongwei Li
Zhongwei Li
QZQizhe Zhang
Qizhe Zhang
We mainly study the influence of surface charge on the movement and distribution characteristics of metal particle dust (MPD) in DC GIS/GIL. Based on the improved boundary element algorithm, we establish the movement model of MPD. Combined with experiments, we obtained the distribution characteristics of MPD. The research results show that under negative voltage, the metal particle contamination is more serious at convex side of the spacer. Homopolar surface charge enhances the adhesion of MPD near the spacer, but it also enhances the repulsion between spacer and MPD in chamber. Heteropolar surface charge weakens the adhesion of MPD near the spacer, but it also weakens the repulsion between spacer and MPD in chamber. Therefore, we suggest that surface regulation should be adopted to make the spacer surface accumulate homopolar surface charge. Meanwhile particle traps should be installed near the spacer and in middle of the chamber to achieve more comprehensive metal particle suppression.

27 October 2021 in Electronics
Verified
Journal Article
Open access
PDF file
QZQizhe Zhang
Qizhe Zhang
SWShenghui WANG
Shenghui WANG
XDXinghao Dong
Xinghao Dong
MLMingliang Liu
Mingliang Liu
QOQi Ou
Qi Ou
FLFangcheng Lv
Fangcheng Lv
The traction power supply system of an Electrical Multiple Unit (EMU) often suffers from overvoltage impact. As an important protection device for on-board electrical equipment, the working environment of a roof arrester is worse than that of a power system. In recent years, the explosion failure of the roof arresters of an EMU has occurred from time to time, which seriously endangers the safe operation of high-speed railways. In this paper, the electrical performance test and material micro test of roof arrester in three states of normal, defect, and exploded, are carried out in order to study the internal causes of roof arrester explosion and clarify its deterioration mechanism. Using the DC reference voltage test and leakage current test, the electrical performance differences of normal, defective, and exploded arresters are obtained. By studying the disassembly of an arrester, the appearance characteristics of arrester varistor in three states are obtained. The micro morphology and chemical elements of the varistor are analyzed by Scanning Electron Microscope and Energy Dispersive Spectrometer. The deterioration mechanism of the arrester varistor is then revealed, and preventive measures for the explosion failure of the roof arrester are put forward. The obtained results show that, during the long-term operation of the roof arrester of an EMU, the varistor may be damp, and therefore the aluminum electrode layer and side insulation layer of the varistor may deteriorate. After the deterioration of the aluminum electrode layer, the content of the O element increases, and multiple film structures are formed on the surface. After the deterioration of the side insulating layer, the content of the O element increases, and the surface becomes uneven. Improving the sealing performance requirements of the roof arrester and optimizing the maintenance process can reduce its explosion failure.

4 March 2022 in High Voltage
Verified
Journal Article
Open access
QZQizhe Zhang
Qizhe Zhang
SWShenghui Wang
Shenghui Wang
KSKaixuan Sun
Kaixuan Sun
XDXinghao Dong
Xinghao Dong
MLMingliang Liu
Mingliang Liu
FLFangcheng Lü
Fangcheng Lü
The roof arrester of electric multiple units (EMU) can efficiently limit the overvoltage, and ensure the safe operation of the EMU electrical equipment. In the process of high‐speed operation, the traction power supply system is often affected by overvoltage. In addition, roof arrester explosion accidents occasionally occur. In this paper, the on‐line voltage measurement system of the EMU arrester is developed. By analysing a large number of voltage waveforms, the abnormal voltage is divided into three categories: over‐phase voltage, high harmonic voltage and steep impulse overvoltage. The characteristics of abnormal voltage waveforms are then summarised. The electrothermal coupling simulation model of the arrester is developed, and the current response and temperature distribution of the arrester under abnormal voltage are calculated. The impact of the impulse voltage energy on the arrester temperature is studied by applying a triangular wave voltage to the model. Finally, some suggestions are proposed for the operation and maintenance of the roof arrester.

8 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SWShenghui WANG
Shenghui WANG
QOQi Ou
Qi Ou
SLShengfeng Lei
Shengfeng Lei
HLHuaqi Liu
Huaqi Liu
SMShuaitao Mao
Shuaitao Mao
FLFangcheng Lv
Fangcheng Lv
In order to analyze the explosion accidents of the CRH5 EMU roof arrester in recent years, an internal temperature measuring platform based on fluorescence fiber was established, and the temperature distribution characteristics under the continuous operating voltage and high-current impulse were analyzed. The test results show that passing section overvoltage and steep impulse overvoltage have higher amplitudes, while high-harmonic overvoltage has a lower amplitude but a longer duration. The maximum temperature rise of the arrester was 5.2 °C under 34 kV for 3 h. The surface temperature of the valve plate column was high in the middle and low on both sides; the maximum temperature difference at different positions was only 2.2 °C. The maximum temperature of the valve plate column rose to 97.6 °C under 105 times of the high-current impulse, and the maximum temperature difference at different positions reached 33.8 °C. Then, the actual overvoltage of the arrester in operation was measured and analyzed statistically, and the arrester simulation model was established. The temperature characteristics of the normal arrester and the arrester with the electric tree were studied under the actual typical overvoltage, and the influence of air velocity on the internal temperature rise was analyzed. The simulation results show that, due to the low amplitude and small current of high-harmonic overvoltage, the internal temperature rise of the normal and defective arresters was very small. Under the effects of passing section overvoltage and steep impulse overvoltage, the internal temperature of the normal arrester can reach 36.57 °C and 241 °C, and the arrester with the electric tree defect can reach 44.75 °C and 536 °C, respectively. The air velocity has little effect on the internal temperature rise of the arrester. Passing section overvoltage and steep impulse overvoltage occur frequently and have an obvious influence on the internal temperature rise of the arrester, so the roof overvoltage of the EMU is an important reason for the arrester burst.

11 September 2026 in Electronics
Verified
Journal Article
Open access
PDF file
QZQizhe Zhang
Qizhe Zhang
YZYi Zhang
Yi Zhang
ZCZhengwei Chang
Zhengwei Chang
ZWZheng Wang
Zheng Wang
GPGuozheng Peng
Guozheng Peng
Automated power-worksite monitoring requires accurate event recognition and auditable explanations. This paper presents PowerXGraph++, a regulation-constrained spatiotemporal evidence-graph framework for missing PPE, boundary crossing, unsafe proximity, falls, and fire/smoke. Typed evidence tokens are encoded by a transformer; full-context prediction is separated from explanation selection, and explanations are tested for sufficiency, necessity, sparsity, and regulation consistency. Distillation, event-boundary counterfactuals, background-invariance training, and non-inferiority checkpoint selection preserve predictive performance. On annotation-derived construction-PPE graphs, three-seed Macro-F1, violation recall, and rationale F1 were 0.989, 0.965, and 0.901. Under the same frozen predictor, the supervised, grammar-aware selector attained rationale F1 of 0.983 and regulation consistency of 1.000, although the post hoc baselines lacked equivalent supervision. A single YOLO reproduction run using seed 17 on 197 matched person graphs yielded Macro-F1 of 0.844, missing-PPE recall of 0.591, and rationale F1 of 0.660. Expert evaluation produced Fleiss’ kappa of 0.740 and method-to-majority rationale F1 of 0.870. Held-out-camera reasoning and a two-camera fence-crossing pilot provide additional evidence under supplied-evidence conditions; the results do not establish automatic generation of every semantic predicate or unrestricted raw video performance.