Omar Castillo‐Cruz

Omar Castillo‐Cruz

Auto-generated profile, based on publicly available information

Omar Castillo‐Cruz

Centro de Investigacion Cientifica de Yucatan A.C, Calle 43 # 130 x 32 y 34, Colonia Chuburna de Hidalgo, Merida 97205, Yucatan, Mexico

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
OCO. Castillo-Cruz
O. Castillo-Cruz
CPCésar Pérez-Aranda
César Pérez-Aranda
FGF. Gamboa
F. Gamboa
JUAN VALERIO CAUICH-RODRIGUEZJUAN VALERIO CAUICH-RODRIGUEZ
JUAN VALERIO CAUICH-RODRIGUEZ
DMDiego Mantovani
Diego Mantovani
FAF. Avilés
F. Avilés

1 September 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
OCO. Castillo-Cruz
O. Castillo-Cruz
FAF. Avilés
F. Avilés
RVR. Vargas-Coronado
R. Vargas-Coronado
JUAN VALERIO CAUICH-RODRIGUEZJUAN VALERIO CAUICH-RODRIGUEZ
JUAN VALERIO CAUICH-RODRIGUEZ
LCL.H. Chan-Chan
L.H. Chan-Chan
Laura PeponiLaura Peponi
Laura Peponi

24 March 2020 in International Journal of Polymeric Materials and Polymeric Biomaterials
Verified
Journal Article
Closed access
MBMarcos Bonilla-Hernández
Marcos Bonilla-Hernández
GZGuido Antonio Zapata-Catzin
Guido Antonio Zapata-Catzin
OCOmar de Jesús Castillo-Cruz
Omar de Jesús Castillo-Cruz
RCRossana Faride Vargas Coronado
Rossana Faride Vargas Coronado
JCJosé Manuel Cervantes-Uc
José Manuel Cervantes-Uc
JUAN VALERIO CAUICH-RODRIGUEZJUAN VALERIO CAUICH-RODRIGUEZ
JUAN VALERIO CAUICH-RODRIGUEZ
Segmented polyurethanes (SPU) were synthesized with Pluronic F127 (PLU) as soft segment and 4,4′-methylene-bis(cyclohexyl) diisocyanate (HMDI) and Metformin (Met) as rigid segment (HMDI-Met) while antidiabetic content increased by using 20%, 30%, 40%, and 50% of rigid segments. The Met incorporation was provided by FTIR, Raman, NMR, and XPS. By increasing the content of rigid segments, the first decomposition temperature tends to increase from 317 °C to 361 °C while Tg was modified from −80 °C to −50 °C. Mass loss was observed during accelerated degradation and therefore SPU-PLU-Met can deliver up to 40 µg/30 days of Met. Cytotoxicity test showed no deleterious effect.

9 June 2021 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
GZGualberto Antonio Zumbardo‐Bacelis
Gualberto Antonio Zumbardo‐Bacelis
LMLinnette Aracely Meza‐Villegas
Linnette Aracely Meza‐Villegas
CPCésar Pérez-Aranda
César Pérez-Aranda
RCRossana Faride Vargas Coronado
Rossana Faride Vargas Coronado
OCOmar Castillo‐Cruz
Omar Castillo‐Cruz
JUAN VALERIO CAUICH-RODRIGUEZJUAN VALERIO CAUICH-RODRIGUEZ
JUAN VALERIO CAUICH-RODRIGUEZ

28 March 2023 in Polymers
Verified
Journal Article
Open access
PDF file
DADavid Aguilar-Perez
David Aguilar-Perez
CUCindy Maria Urbina-Mendez
Cindy Maria Urbina-Mendez
BMBeatriz Maldonado-Gallegos
Beatriz Maldonado-Gallegos
OCOmar de Jesus Castillo-Cruz
Omar de Jesus Castillo-Cruz
FAFernando Javier Aguilar-Ayala
Fernando Javier Aguilar-Ayala
JUAN VALERIO CAUICH-RODRIGUEZJUAN VALERIO CAUICH-RODRIGUEZ
JUAN VALERIO CAUICH-RODRIGUEZ
Background: We assessed the effect of propolis on the antibacterial, mechanical, and adhesive properties of a commercial poly(alkenoate) cement. Methods: The cement was modified with various concentrations of propolis, and antibacterial assays were performed against S. mutans by both MTT assays and agar diffusion tests. The compressive, flexural, and adhesive properties were also evaluated. Results: the modified cement showed activity against S. mutans in both assays, although reductions in compressive (from 211.21 to 59.3 MPa) and flexural strength (from 11.1 to 6.2 MPa) were noted with the addition of propolis, while adhesive strength (shear bond strength and a novel pull-out method) showed a statistical difference (p < 0.05). Conclusion: the antiseptic potential of modified material against S. mutans will allow this material to be used in cases in which low mechanical resistance is required (in addition to its anti-inflammatory properties) when using atraumatic restorative techniques, especially in deep cavities.

1 January 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
CPCésar Pérez-Aranda
César Pérez-Aranda
FPFidel Fernando Gamboa Perera
Fidel Fernando Gamboa Perera
OCO. Castillo-Cruz
O. Castillo-Cruz
JCJ. V. Cauich-Rodríguez
J. V. Cauich-Rodríguez
FAF. Avilés
F. Avilés
The design and analysis of a device to measure the burst strength (strength under a state of pure radial internal pressure) and compliance of vascular grafts and flexible pressurized tubes is presented. The device comprises three main sections, viz., a clean air-dry pressure controller, a test specimen holder, and automated software for control and data collection. Air pressure is controlled by means of a valve and a dedicated mechanism allowing reaching up to 120 psi in increments of 1 psi, and recording pressure changes with 0.04 psi resolution. The circumferential strain is determined by measuring the radial displacement of the vascular graft using an optical arrangement capable of determining a maximum radial displacement of 10 mm with 0.02 mm resolution. The instrument provides a low uncertainty in compliance (±0.32%/100 mm Hg−1) and burst strength measurements. Due to its simplicity, the device can easily be reproduced in other laboratories contributing to a dedicated instrument with high resolution at low cost. The reliability of the apparatus is further confirmed by conducting finite element analysis, elasticity solutions for pressurized cylinders, and testing of small diameter vascular grafts made of a commercial aliphatic polyurethane tested under radial internal pressure.