The interactions of medical devices within the body area network (BAN) have significantly alleviated the pressure on healthcare resources attributed to an aging society. However, the low-power, high-reliability wireless communications among these devices are susceptible to the influence of the human body. This paper exploits the capacitive effects of human tissues to achieve precise and reconfigurable impedance matching in magnetic resonance coupling (MRC) human body communication to minimize the adverse effects of the human body. First, the impact mechanism of the human body on MRC port impedance is analyzed in this paper under the inductive near-field based on the dielectric dispersion of human tissues. This mechanism helps identify the quasistatic magnetic field within MRC, from which the resonance conditions of MRC are derived. A reconfigurable impedance matching method within a broad bandwidth is proposed using these conditions, and experiments on port impedance and transmission characteristics are conducted using an optimized variable parameter coil as the implementation medium. Results demonstrate that the proposed method can precisely tune within a range of 10 MHz under inductive near-field, confirming the reliability of the resonance conditions and matching methodology. After matching, the MRC exhibits only 12.5 dB @13.56 MHz path loss over a 90 cm transmission distance, surpassing other methods by more than 52.8%. The optimized MRC provides an effective technical foundation for narrowband communication schemes of medical devices in the BAN.
1 February 2024 in IEEE Transactions on Biomedical Circuits and Systems
Intracardiac wireless communication is crucial for the development of multi-chamber leadless cardiac pacemakers (LCP). However, the time-varying characteristics of intracardiac channel pose major challenges. As such, mastering the dynamic conduction properties of the intracardiac channel and modeling the equivalent time-varying channel are imperative for realizing LCP multi-chamber pacing. In this paper, we present a limiting volume variational approach based on the electrical properties of cardiac tissues and trends in chamber volume variation. This approach was used to establish a quasi-static and a continuous time-varying equivalent circuit model of an intracardiac channel. An equivalence analysis was conducted on the model, and a discrete time-varying equivalent circuit phantom grounded on the cardiac cycle was subsequently established. Moreover, an ex vivo cardiac experimental platform was developed for verification. Results indicate that in the frequency domain, the congruence between phantom and ex vivo experimental outcomes is as high as 94.3%, affirming the reliability of the equivalent circuit model. In the time domain, the correlation is up to 75.3%, corroborating its effectiveness. The proposed time-varying equivalent circuit model exhibits stable and standardized dynamic attributes, serving as a powerful tool for addressing time-varying challenges and simplifying in vivo or ex vivo experiments.