Jiejie Yang

Jiejie Yang

Auto-generated profile, based on publicly available information

Jiejie Yang

Fuzhou University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
QZQi Zheng
Qi Zheng
HWHuihuang Wu
Huihuang Wu
HJHaiyan Jiang
Haiyan Jiang
JYJiejie Yang
Jiejie Yang
YueMing GaoYueMing Gao
YueMing Gao
Fluorescence immunochromatographic assay (FICA) is a rapid immunoassay technique that has the characteristics of high precision and sensitivity. Although image FICA strip readers have the advantages of high portability and easy operation, the use of high-precision complementary metal oxide semiconductor (CMOS) image sensors leads to an increase in overall cost. Considering the popularity of CMOS image sensors in smartphones and their powerful processing functions, this work developed a smartphone-based FICA strip reader. An optical module suitable for the test strips with different fluorescent markers was designed by replacing the excitation light source and the light filter. An android smartphone was used for image acquisition and image denoising. Then, the test and control lines of the test strip image were recognized by the sliding window algorithm. Finally, the characteristic value of the strip image was calculated. A linear detection range from 10 to 5000 mIU/mL (R2 = 0.95) was obtained for human chorionic gonadotrophin with the maximum relative error less than 9.41%, and a linear detection range from 5 to 4000 pg/mL (R2 = 0.99) was obtained for aflatoxin B1, with the maximum relative error less than 12.71%. Therefore, the smartphone-based FICA strip reader had high portability, versatility, and accuracy.

27 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
HYHongli Yan
Hongli Yan
XYXudong Yang
Xudong Yang
YLYanyan Liu
Yanyan Liu
WHWanting He
Wanting He
YLYipeng Liao
Yipeng Liao
YueMing GaoYueMing Gao
YueMing Gao
The respiratory rate is one of the crucial indicators for monitoring human physiological health. The purpose of this paper was to introduce a head-mounted respiratory monitoring solution based on electrical impedance sensing. Firstly, we constructed a finite element model to analyze the feasibility of using head impedance for respiratory sensing based on the physiological changes in the pharynx. After that, we developed a circuit module that could be integrated into a head-mounted respiratory monitoring device using a bioelectrical impedance sensor. Furthermore, we combined adaptive filtering and respiratory tracking algorithms to develop an app for a mobile phone. Finally, we conducted controlled experiments to verify the effectiveness of this electrical impedance sensing system for extracting respiratory rate. We found that the respiration rates measured by the head-mounted electrical impedance respiratory monitoring system were not significantly different from those of commercial respiratory monitoring devices by a paired t-test (p > 0.05). The results showed that the respiratory rates of all subjects were within the 95% confidence interval. Therefore, the head-mounted respiratory monitoring scheme proposed in this paper was able to accurately measure respiratory rate, indicating the feasibility of this solution. In addition, this respiratory monitoring scheme helps to achieve real-time continuous respiratory monitoring, which can provide new insights for personalized health monitoring.

12 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YLYiming Liu
Yiming Liu
YueMing GaoYueMing Gao
YueMing Gao
LCLiting Chen
Liting Chen
TLTao Liu
Tao Liu
JYJiejie Yang
Jiejie Yang
MDMin Du
Min Du
Conductive intracardiac communication (CIC) has become one of the most promising technologies in multisite leadless pacemakers for cardiac resynchronization therapy. Existing studies have shown that cardiac pulsation has a significant impact on the attenuation of intracardiac communication channels. In this study, a novel variable-volume circuit-coupled electrical field heart model, which contains blood and myocardium, is proposed to verify the phenomenon. The influence of measurements was combined with the model as the equivalent circuit. Dynamic intracardiac channel characteristics were obtained by simulating models with varying volumes of the four chambers according to the actual cardiac cycle. Subsequently, in vitro experiments were carried out to verify the model’s correctness. Among the dependences of intracardiac communication channels, the distance between pacemakers exerted the most substantial influence on attenuation. In the simulation and measurement, the relationship between channel attenuation and pulsation was found through the variable-volume heart model and a porcine heart. The CIC channel attenuation had a variation of less than 3 dB.

6 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ZWZiliang Wei
Ziliang Wei
YWYangrong Wen
Yangrong Wen
YueMing GaoYueMing Gao
YueMing Gao
MYMingjing Yang
Mingjing Yang
JYJiejie Yang
Jiejie Yang
MDMin Du
Min Du
Intrabody communication (IBC) can achieve better power efficiency and higher levels of security than other traditional wireless communication technologies. Currently, the majority of research on the body channel characteristics of galvanic coupling IBC are motionless and have only been evaluated in the frequency domain. Given the long measuring times of traditional methods, the access to dynamic variations and the simultaneous evaluation of the time-frequency domain remains a challenge for dynamic body channels such as the cardiac channel. To address this challenge, we proposed a parallel measurement methodology with a multi-tone strategy and a time-parameter processing approach to obtain a time-frequency evaluation for dynamic body channels. A group search algorithm has been performed to optimize the crest factor of multitone excitation in the time domain. To validate the proposed methods, in vivo experiments, with both dynamic and motionless conditions were measured using the traditional method and the proposed method. The results indicate that the proposed method is more time efficient (Tmeas=1 ms) with a consistent performance (ρc > 98%). Most importantly, it is capable of capturing dynamic variations in the body channel and provides a more comprehensive evaluation and richer information for the study of IBC.

8 August 2024 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
ZWZiliang Wei
Ziliang Wei
SYShuang Yang
Shuang Yang
ZCZhizhang (David) Chen
Zhizhang (David) Chen
MVMang.I Vai
Mang.I Vai
Sio Hang PunSio Hang Pun
Sio Hang Pun
YGYueming Gao
Yueming Gao
The interactions of medical devices within the body area network (BAN) have significantly alleviated the pressure on healthcare resources attributed to an aging society. However, the low-power, high-reliability wireless communications among these devices are susceptible to the influence of the human body. This paper exploits the capacitive effects of human tissues to achieve precise and reconfigurable impedance matching in magnetic resonance coupling (MRC) human body communication to minimize the adverse effects of the human body. First, the impact mechanism of the human body on MRC port impedance is analyzed in this paper under the inductive near-field based on the dielectric dispersion of human tissues. This mechanism helps identify the quasistatic magnetic field within MRC, from which the resonance conditions of MRC are derived. A reconfigurable impedance matching method within a broad bandwidth is proposed using these conditions, and experiments on port impedance and transmission characteristics are conducted using an optimized variable parameter coil as the implementation medium. Results demonstrate that the proposed method can precisely tune within a range of 10 MHz under inductive near-field, confirming the reliability of the resonance conditions and matching methodology. After matching, the MRC exhibits only 12.5 dB @13.56 MHz path loss over a 90 cm transmission distance, surpassing other methods by more than 52.8%. The optimized MRC provides an effective technical foundation for narrowband communication schemes of medical devices in the BAN.

1 February 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
ZWZiliang Wei
Ziliang Wei
HWHan Wang
Han Wang
DLDongming Li
Dongming Li
MVMang.I Vai
Mang.I Vai
Sio Hang PunSio Hang Pun
Sio Hang Pun
YueMing GaoYueMing Gao
YueMing Gao
Intracardiac wireless communication is crucial for the development of multi-chamber leadless cardiac pacemakers (LCP). However, the time-varying characteristics of intracardiac channel pose major challenges. As such, mastering the dynamic conduction properties of the intracardiac channel and modeling the equivalent time-varying channel are imperative for realizing LCP multi-chamber pacing. In this paper, we present a limiting volume variational approach based on the electrical properties of cardiac tissues and trends in chamber volume variation. This approach was used to establish a quasi-static and a continuous time-varying equivalent circuit model of an intracardiac channel. An equivalence analysis was conducted on the model, and a discrete time-varying equivalent circuit phantom grounded on the cardiac cycle was subsequently established. Moreover, an ex vivo cardiac experimental platform was developed for verification. Results indicate that in the frequency domain, the congruence between phantom and ex vivo experimental outcomes is as high as 94.3%, affirming the reliability of the equivalent circuit model. In the time domain, the correlation is up to 75.3%, corroborating its effectiveness. The proposed time-varying equivalent circuit model exhibits stable and standardized dynamic attributes, serving as a powerful tool for addressing time-varying challenges and simplifying in vivo or ex vivo experiments.