Primary diabetes care and diabetic retinopathy (DR) screening persist as major public health challenges due to a shortage of trained primary care physicians (PCPs), particularly in low-resource settings. Here, to bridge the gaps, we developed an integrated image–language system (DeepDR-LLM), combining a large language model (LLM module) and image-based deep learning (DeepDR-Transformer), to provide individualized diabetes management recommendations to PCPs. In a retrospective evaluation, the LLM module demonstrated comparable performance to PCPs and endocrinology residents when tested in English and outperformed PCPs and had comparable performance to endocrinology residents in Chinese. For identifying referable DR, the average PCP’s accuracy was 81.0% unassisted and 92.3% assisted by DeepDR-Transformer. Furthermore, we performed a single-center real-world prospective study, deploying DeepDR-LLM. We compared diabetes management adherence of patients under the unassisted PCP arm (n = 397) with those under the PCP+DeepDR-LLM arm (n = 372). Patients with newly diagnosed diabetes in the PCP+DeepDR-LLM arm showed better self-management behaviors throughout follow-up (P < 0.05). For patients with referral DR, those in the PCP+DeepDR-LLM arm were more likely to adhere to DR referrals (P < 0.01). Additionally, DeepDR-LLM deployment improved the quality and empathy level of management recommendations. Given its multifaceted performance, DeepDR-LLM holds promise as a digital solution for enhancing primary diabetes care and DR screening.
We have developed a digital twin-based CKD identification and prediction model that leverages generalized metabolic fluxes (GMF) for patients with Type 2 Diabetes Mellitus (T2DM). GMF digital twins utilized basic clinical and physiological biomarkers as inputs for identification and prediction of CKD. We employed four diverse multi-ethnic cohorts (n = 7072): a Singaporean cohort (EVAS, n = 289) and a North American cohort (NHANES, n = 1044) for baseline CKD identification, and two multi-center Singaporean cohorts (CDMD, n = 2119 and SDR, n = 3627) for 3-year CKD prediction and risk stratification. We subsequently conducted a comprehensive study utilizing a single dataset to evaluate the clinical utility of GMF for CKD prediction. The GMF-based identification model performed strongly, achieving an AUC between 0.80 and 0.82. In prediction, the GMF generated with complete parameters attained high performance with an AUC of 0.86, while with incomplete parameters, it achieved an AUC of 0.75. The GMF-based prediction model utilizing complete inputs is the standard implementation of our algorithm: HealthVector Diabetes®. We have established the GMF digital twin-based model as a robust clinical tool capable of predicting and stratifying the risk of future CKD within a 3-year time horizon. We report the correlation of GMF with basic input parameters, their ability to differentiate between future health states and medication status at baseline, and their capability to quantify CKD progression rates. This holistic methodology provides insights into patients’ health states and CKD progression rates based on GMF metabolic profile differences, enabling personalized care plans.
The coronavirus disease 2019 (COVID-19) pandemic has magnified the insufficient readiness of humans in dealing with such an unexpected occurrence. During the pandemic, sustainable development goals have been hindered severely. Various observations and lessons have been highlighted to emphasise local impacts on a single region or single sector, whilst the holistic and coupling impacts are rarely investigated. This study overviews the structural changes and spatial heterogeneities of changes in healthcare, energy and environment, and offers perspectives for the in-depth understanding of the COVID-19 impacts on the three sectors, in particular the cross-sections of them. Practical observations are summarised through the broad overview. A novel concept of the healthcare–energy–environment nexus under climate change constraints is proposed and discussed, to illustrate the relationships amongst the three sectors and further analyse the dynamics of the attention to healthcare, energy and environment in view of decision-makers. The society is still on the way to understanding the impacts of the whole episode of COVID-19 on healthcare, energy, environment and beyond. The raised nexus thinking could contribute to understanding the complicated COVID-19 impacts and guiding sustainable future planning.
Background: We investigate the association between mean HbA1c, HbA1c variability, and all-cause mortality and diabetes-related macrovascular complications in patients with diabetes. Methods: We performed a retrospective cohort study using patients present in the Singapore Health Services diabetes registry (SDR) during 2013 to 2014. We assessed mean HbA1c using three models: a baseline mean HbA1c for 2013– 14, the mean across the whole follow-up period, and a time-varying yearly updated mean. We assessed HbA1c variability at baseline using the patient’s HbA1c variability score (HVS) for 2013– 14. The association between mean HbA1c, HVS, and 6 outcomes were assessed using Cox proportional hazard models. Results: We included 43,837– 53,934 individuals in the analysis; 99.3% had type 2 diabetes mellitus. The data showed a J-shaped distribution in adjusted hazard ratios (HRs) for all-cause mortality, ischemic heart disease, acute myocardial infarction, peripheral arterial disease, and ischemic stroke, with an increased risk of developing these outcomes at HbA1c < 6% (42 mmol/mol) and ≥ 8% (64 mmol/mol). With the addition of HVS, the J-shaped distribution was maintained for the above outcomes, but HRs were greater at HbA1c < 6.0% (42 mmol/mol) and reduced at HbA1c ≥ 8.0% (64 mmol/mol) when compared to models without HVS. The risk for all outcomes increased substantially with increasing glycaemic variability. Conclusion: Both low (< 6.0% [42 mmol/mol]) and high (≥ 8.0% [64 mmol/mol]) levels of glycaemic control are associated with increased all-cause mortality and diabetes-related macrovascular complications. Glycaemic variability is independently associated with increased risk for these outcomes. Therefore, patients with stable glycaemic level of 6– 8% (42– 64mmol/mol) are at lowest risk of all-cause mortality and diabetes-related macrovascular complications.
6 October 2024 in Journal of Diabetes Science and Technology
Introduction: An error grid compares measured versus reference glucose concentrations to assign clinical risk values to observed errors. Widely used error grids for blood glucose monitors (BGMs) have limited value because they do not also reflect clinical accuracy of continuous glucose monitors (CGMs). Methods: Diabetes Technology Society (DTS) convened 89 international experts in glucose monitoring to (1) smooth the borders of the Surveillance Error Grid (SEG) zones and create a user-friendly tool—the DTS Error Grid; (2) define five risk zones of clinical point accuracy (A-E) to be identical for BGMs and CGMs; (3) determine a relationship between DTS Error Grid percent in Zone A and mean absolute relative difference (MARD) from analyzing 22 BGM and nine CGM accuracy studies; and (4) create trend risk categories (1-5) for CGM trend accuracy. Results: The DTS Error Grid for point accuracy contains five risk zones (A-E) with straight-line borders that can be applied to both BGM and CGM accuracy data. In a data set combining point accuracy data from 18 BGMs, 2.6% of total data pairs equally moved from Zones A to B and vice versa (SEG compared with DTS Error Grid). For every 1% increase in percent data in Zone A, the MARD decreased by approximately 0.33%. We also created a DTS Trend Accuracy Matrix with five trend risk categories (1-5) for CGM-reported trend indicators compared with reference trends calculated from reference glucose. Conclusion: The DTS Error Grid combines contemporary clinician input regarding clinical point accuracy for BGMs and CGMs. The DTS Trend Accuracy Matrix assesses accuracy of CGM trend indicators.
Purpose: To describe the inception and structure of the SingHealth Diabetes Registry (SDR) as well as the methodology used to set up the registry. The SDR was established to facilitate systematic and standardized data collection for diabetes mellitus within Singapore Health Services (SingHealth), which is an Academic Medical Center (AMC) and Singapore’s largest group of healthcare institutions. The diabetes casemix and outcome variables within the registry cohort are also provided. Materials and Methods: The SDR is built from SingHealth’s electronic medical records (EMR) and clinical databases. It covers all individuals aged 18 and above with diabetes mellitus, excluding those with pre-diabetes. Cases are annually ascertained using criteria that include diagnosis codes, prescription records and laboratory test records. Data collection of casemix and outcome variables for the period 2013 to 2019 is complete. Results: The SDR stands at 208,102 ascertained individuals, distributed across 8 healthcare sites within the AMC. The cohort is broadly reflective of the local gender and ethnic compositions but has a high proportion of older individuals with a mean age of 65.8 ± 13.7 years. Majority (> 99%) have type 2 diabetes mellitus, with multiple other comorbidities (hypertension 84.1%, hyperlipidemia 86.2%, established cardiovascular disease 34.1%). At present, majority of individuals are able to meet key process indicators and 52.7% have a mean HbA1c of < 7% (53 mmol/mol). Areas of potential improvement include increasing eye and foot screening rates, as well as glycemic control for the 19.5% of individuals with mean HbA1c > 8% (64 mmol/mol). Conclusion: The SDR is a large-scale, comprehensive, and representative diabetes registry that incorporates EMR data across the primary and hospital-based care continuum, in a major AMC in Singapore. The SDR has identified areas of improvement in diabetes processes and outcomes. It will support future quality assessment and improvements in diabetes care.