Norwahida Yusoff

Norwahida Yusoff

Auto-generated profile, based on publicly available information

Norwahida Yusoff

School of Mechanical Engineering, Tuanku Syed Sirajuddin Engineering Campus Universiti Sains Malaysia, Nibong Tebal, Malaysia

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2011 in Medical Engineering & Physics
Verified
Journal Article
Closed access
NYNorwahida Yusoff
Norwahida Yusoff
NONoor Azuan Abu Osman
Noor Azuan Abu Osman
BPBelinda Pingguan-Murphy
Belinda Pingguan-Murphy
A mechanical-conditioning bioreactor has been developed to provide bi-axial loading to three-dimensional (3D) tissue constructs within a highly controlled environment. The computer-controlled bioreactor is capable of applying axial compressive and shear deformations, individually or simultaneously at various regimes of strain and frequency. The reliability and reproducibility of the system were verified through validation of the spatial and temporal accuracy of platen movement, which was maintained over the operating length of the system. In the presence of actual specimens, the system was verified to be able to deliver precise bi-axial load to the specimens, in which the deformation of every specimen was observed to be relatively homogeneous. The primary use of the bioreactor is in the culture of chondrocytes seeded within an agarose hydrogel while subjected to physiological compressive and shear deformation. The system has been designed specifically to permit the repeatable quantification and characterisation of the biosynthetic activity of cells in response to a wide range of short and long term multi-dimensional loading regimes.

24 July 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MMMohammed A. Mousa
Mohammed A. Mousa
AHAdam Husein
Adam Husein
MEMohamed I. El-Anwar
Mohamed I. El-Anwar
NYNorwahida Yusoff
Norwahida Yusoff
Johari Yap AbdullahJohari Yap Abdullah
Johari Yap Abdullah

15 September 2022 in Progress in Biophysics and Molecular Biology
Verified
Journal Article
Closed access
SNSiti Hawa Ngalim
Siti Hawa Ngalim
NYNorwahida Yusoff
Norwahida Yusoff
RJRayzel Renitha Johnson
Rayzel Renitha Johnson
SRSiti Razila Abdul Razak
Siti Razila Abdul Razak
XCXinyue Chen
Xinyue Chen
Yeong Yeh LeeYeong Yeh Lee
Yeong Yeh Lee

10 February 2023 in Journal of Failure Analysis and Prevention
Verified
Journal Article
Closed access
PDF file
NYNorwahida Yusoff
Norwahida Yusoff
FYFeizal Yusof
Feizal Yusof

8 September 2023 in Pertanika Journal of Science and Technology
Verified
Journal Article
Open access
RMRehana Munas
Rehana Munas
KYKok Hwa Yu
Kok Hwa Yu
NYNorwahida Yusoff
Norwahida Yusoff
Abdul Majeed MuzathikAbdul Majeed Muzathik
Abdul Majeed Muzathik
MIMohd Azmi Ismail
Mohd Azmi Ismail
Pertanika Journal information and guidelines

16 May 2022 in International Journal of Ventilation
Verified
Journal Article
Closed access
PBPravinth Balthazar
Pravinth Balthazar
NYNorwahida Yusoff
Norwahida Yusoff
MIMohd Azmi Ismail
Mohd Azmi Ismail
In dry climates, evaporative cooling techniques are frequently used in place of air-conditioners to increase energy efficiency and reduce installation costs. An evaporative nozzle is a type of evaporative cooling technique. Evaporative nozzle spraying is a technique that is used in a variety of applications, including cooling and humidification. The performance of evaporative spray nozzles with a number ranging from 2 to 8 nozzles has been examined in terms of nozzle combinations, orientations (horizontal and vertical), and Reynolds numbers ranging from 13000 to 83000. In general, the results show that relative humidity is inversely proportional to the Reynolds number. Furthermore, the nozzle numbers are proportional to the relative humidity. As the number of nozzles in a vertical arrangement increases from 2 to 8, the relative humidity rises to 90%. For 8 spray nozzles, the vertical arrangement produces 7.4% higher outlet relative humidity than the horizontal arrangement. The current investigation’s highest relative humidity is 90%, which occurs for 8 nozzles in the vertical direction at Reynolds number 13300. Moreover, the horizontal and vertical correlations were developed to predict the outlet relative humidity with respect to the nozzle orientation.