Mariko Matsumoto

Mariko Matsumoto

Auto-generated profile, based on publicly available information

Mariko Matsumoto

Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Japanese Dental Science Review
Verified
Journal Article
Open access
HSHidehiko Sano
Hidehiko Sano
ACAbu Faem Mohammad Almas Chowdhury
Abu Faem Mohammad Almas Chowdhury
PSPipop Saikaew
Pipop Saikaew
MMMariko Matsumoto
Mariko Matsumoto
SHShuhei Hoshika
Shuhei Hoshika
Monica YamautiMonica Yamauti
Monica Yamauti
Microtensile bond strength (μTBS) test was introduced in 1994. Since then, it has been utilized profoundly across many bond strength testing laboratories, making it currently one of the most standard and versatile bond strength test. Although it is a static and strength-based method, together with the morphological and spectroscopic investigations, it has been contributing immensely in the advancement of dentin adhesive systems. μTBS test has a greater discriminative capability than the traditional macro-shear bond test. During the early stage of its development, the authors predicted that this testing method would enable evaluation of the adhesive performances of resins to excavated carious or sclerotic dentin and the regional bond strengths of various portions of the cavity. In addition, they also stated the possibility of comparing the long-term stability of resin adhesion at various portions of the cavity walls on teeth extracted at various times after insertion of bonded restorations. In this review, we discussed the historical background, inception and the application of the μTBS test and proposed directions for further improvement of this testing method.

1 January 2016 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
MHMami Higashi
Mami Higashi
MMMariko Matsumoto
Mariko Matsumoto
AKAsuka Kawaguchi
Asuka Kawaguchi
JMJiro Miura
Jiro Miura
TMTakuya Minamino
Takuya Minamino
HYHirofumi Yatani
Hirofumi Yatani
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies

1 October 2014 in Dental Materials
Verified
Journal Article
Closed access
AMAtsushi Mine
Atsushi Mine
JMJan De Munck
Jan De Munck
MCMarcio Vivan Cardoso
Marcio Vivan Cardoso
KLKirsten L. Van Landuyt
Kirsten L. Van Landuyt
APAndré Poitevin
André Poitevin
BMBart Van Meerbeek
Bart Van Meerbeek

1 November 2019 in Japanese Dental Science Review
Verified
Journal Article
Open access
AMAtsushi Mine
Atsushi Mine
TKTomoshige Kabetani
Tomoshige Kabetani
AKAsuka Kawaguchi-Uemura
Asuka Kawaguchi-Uemura
MHMami Higashi
Mami Higashi
YTYuko Tajiri
Yuko Tajiri
HYHirofumi Yatani
Hirofumi Yatani
The purpose of this review was to assess the available literature regarding bonding between current adhesive systems and computer-aided design/computer-aided manufacturing (CAD/CAM) indirect resin materials, to provide clinicians with a comparative overview of the relevant bonding procedures. An electronic search was performed through PubMed based on the keywords CAD/CAM and dental bonding. Additional relevant literature was obtained from the citations in the articles. A total of 313 papers were identified, of which 281 were excluded as being unsuitable, and an additional 3 papers were identified, giving a total of 32 articles that are included in this review. Based on this survey, it is recommended that microretentive surfaces should be generated by either blasting or hydrofluoric acid etching. This initial process should be followed by silanization to ensure chemical adhesion prior to bonding to CAD/CAM indirect resin composite materials (including Lava Ultimet, KATANA AVENCIA block, Gradia Block, Cerasmart, Paradigm, and Block HC) and CAD/CAM polymer-infiltrated ceramics (such as Vita Enamic). The use of materials containing methyl methacrylate (MMA) also appears to improve the bonding of CAD/CAM poly(methyl methacrylate) (PMMA) resin materials (including XHIPC-CAD/CAM, artBloc Temp, and Telio).

1 September 2018 in Operative Dentistry
Verified
Journal Article
Closed access
PSPipop Saikaew
Pipop Saikaew
MMM Matsumoto
M Matsumoto
ACAfma Chowdhury
Afma Chowdhury
RCRm Carvalho
Rm Carvalho
HSH Sano
H Sano
SUMMARY: Objective: This study evaluated the effect of shortened application time on long-term bond strength with universal adhesives.Methods and Materials: Three universal adhesives were used: Clearfil Universal Bond (CU, Kuraray Noritake Dental Inc, Tokyo, Japan), Scotchbond Universal Adhesive (SB, 3M ESPE, St Paul, MN, USA) or G-Premio Bond (GP, GC Corp, Tokyo, Japan). Sixty molars were cut to expose midcoronal dentin and prepared with a regular diamond bur. Each adhesive was applied either according to the manufacturer's instruction or with shortened time. Specimens were stored in distilled water at 37°C for 24 hours and then cut into resin-dentin sticks. Microtensile bond strength (μTBS) was tested after either 24 hours or 1 year of water storage. Data were analyzed by the three-way ANOVA and Duncan tests (α=0.05). Fracture modes were analyzed under a scanning electron microscope (SEM). One dentin stick per group was selected after fracture mode analysis and further observed using transmission electron microscopy (TEM). Six additional dentin discs were prepared and conditioned with each adhesive under the different application time to observe the adhesive-smear layer interaction by SEM.Results: Shortened application time affected the μTBS (p<0.001) while storage time did not affect bond strength (p=0.187). A significant effect of shortened application time on μTBS was observed in the CU at 1 year and in the GP at both storage times.Conclusions: One-year storage time had no effect on the μTBS of universal adhesives to bur-cut dentin. The performance of universal adhesives can be compromised when applied using a shortened application time.

1 February 2017 in Dental Materials
Verified
Journal Article
Closed access
AMAtsushi Mine
Atsushi Mine
JMJan De Munck
Jan De Munck
AEAnnelies Van Ende
Annelies Van Ende
APAndré Poitevin
André Poitevin
MMMariko Matsumoto
Mariko Matsumoto
BMBart Van Meerbeek
Bart Van Meerbeek